The work described in this thesis was done at the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), in the optic division, within the Ph.D. of Metrology of the Politecnico di Torino. My work consisted in developing a new generation optical frequency standard based on Ytterbium atoms: the goal of this project is to realize a clock whose performance overcomes the ones of the standard which actually realizes the Second, the atomic Cesium fountain. This means realizes an apparatus which shows stability and accuracy better then the fountain ones: a possible way adopted in several new generation clock is using optical transitions, because they offer an higher quality factor of the clock transition itself, which means a better stability and the possibility to reach the 10^-17 level in the global accuracy of the clock. The fundamental idea of a clock is to realize as close as possible the basic idea under the actual definition of the Second, that is to fix the unit if time with a particular atomic transition, when the atom is completely unperturbed. Accomplishing this prescription means a lot of work in cooling down the atoms until the 10^-6 K regime using laser cooling techniques, developing a trap where atoms can be excited by the clock laser (the optical lattice) and of course a very careful frequency and amplitude stabilization of the clock laser itself is needed to reach our goal. The work described in this thesis regards the development of the two cooling stages of the Yb atoms and it is presented as follows. Chapter 1 explains with more details why an optical clock is needed to improve the accuracy of the actual realization of the Second, then describing the theoretical framework in which the clock will be developed. Chapter 2 contains a description of the experimental apparatus used, with more attention on the instrumentation related to the laser cooling of the atoms. Chapter 3 is about the characterization of the first cooling stage, both in a static and in a dynamic way, with some attention on the theoretical model developed to perform both the characterizations. Chapter 4 focuses on the development of the second cooling stage and it describes the actual state of the art of this stage
The work described in this thesis was done at the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), in the optic division, within the Ph.D. of Metrology of the Politecnico di Torino. My work consisted in developing a new generation optical frequency standard based on Ytterbium atoms: the goal of this project is to realize a clock whose performance overcomes the ones of the standard which actually realizes the Second, the atomic Cesium fountain. This means realizes an apparatus which shows stability and accuracy better then the fountain ones: a possible way adopted in several new generation clock is using optical transitions, because they offer an higher quality factor of the clock transition itself, which means a better stability and the possibility to reach the 10^-17 level in the global accuracy of the clock. The fundamental idea of a clock is to realize as close as possible the basic idea under the actual definition of the Second, that is to fix the unit if time with a particular atomic transition, when the atom is completely unperturbed. Accomplishing this prescription means a lot of work in cooling down the atoms until the 10^-6 K regime using laser cooling techniques, developing a trap where atoms can be excited by the clock laser (the optical lattice) and of course a very careful frequency and amplitude stabilization of the clock laser itself is needed to reach our goal. The work described in this thesis regards the development of the two cooling stages of the Yb atoms and it is presented as follows. Chapter 1 explains with more details why an optical clock is needed to improve the accuracy of the actual realization of the Second, then describing the theoretical framework in which the clock will be developed. Chapter 2 contains a description of the experimental apparatus used, with more attention on the instrumentation related to the laser cooling of the atoms. Chapter 3 is about the characterization of the first cooling stage, both in a static and in a dynamic way, with some attention on the theoretical model developed to perform both the characterizations. Chapter 4 focuses on the development of the second cooling stage and it describes the actual state of the art of this stage
Master thesis in physics at University of Torino. ABSTRACT :Optical lattice clocks occupy a very important position in metrological research. Diffused worldwide, they are a strong candidate for a future redefinition of the second of the International System of Units (SI) and thanks to their extremely small fractional uncertainty about 10−18 they are involved in fundamental physics experiments, for example in the field of general relativity. In a optical clock, the lattice is used to trap ultracold atoms and it is realized with a retro-reflected laser tuned on magic wavelength to reduce perturbations on the clock transition. An optical lattice is generated usually starting by a titanium:sapphire laser: its main qualities are high output power and narrow linewidth, but it is delicate and difficult to use so its application in new kinds of atomic clocks, such as transportable or spacial, is not strongly recommended. Replacing it with an amplified laser diode would be preferable because these instruments are better for cost, reliability, size and weight, so suitable for applications out of laboratory, but at the same time present the problem of spectral purity as they have a not negligible amplified spontaneous emission (ASE): this phenomenon produces a broad spectrum detuned from magic wavelength inducing a perturbation on the clock transition. In my thesis I investigated experimentally the possibility to generate an optical lattice starting from an amplified laser diode emitting at 759.35 nm, ytterbium magic wavelength, and I applied the laser system that I developed on the atomic clock IT-Yb1 at Istituto Nazionale di Ricerca Metrologica (INRiM) located in Torino. The target of this work is to achieve fractional uncertainty due to ASE below 10−18, making the performances of the two different lasers sources equivalent. First, I calculated the theoretical model of the light shift induced by the lattice on the clock transition between ytterbium atomic states 1S0 →3 P0, comparing it with experimental results and I applied it to estimate ASE contribution to lattice shift. In the experimental part of this work I realized an optical system to study amplified laser diode emission and manipulate laser beam to obtain a good lattice from this laser source, filtering ASE with a volume Bragg grating and controlling power with an acousto optic modulator. Moreover I studied ASE spectral distribution in different conditions and its interaction with optical elements. Next studies foresee to measure experimentally with IT-Yb1 the shift induced by the laser system that I realized to calculate its uncertainty contribution and compare this result with the one obtained with a titanium:sapphire laser. This work will be useful to the development of compact or transportable atomic clocks based exclusively on semiconductor lasers with applications in the generation of optical timescales, travelling optical standards and the measurements of Earth gravitational redshift.
An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.
Since 1967, the Second has been defined by the CGPM as 9,192,631,770 periods of oscillation corresponding to a transition between two hyperfine levels in a Cesium atom with zero external fields. Key to this definition was the fact that as experimentalists found new and more precise ways to measure this frequency, the definition of the second would become more and more accurate with time. However, in the last 30 years, new technologies based on tunable lasers addressing optical transitions in atoms, ions, and molecules have offered an entirely new approach to defining the Second with significantly higher precision and accuracy. Here, I will show that by trapping thousands of atoms inside a specially engineered optical lattice one can create an extremely accurate frequency standard with 2 orders of magnitude improvement over current Cs standards. Furthermore, I will explain that standards based on this technology are fundamentally more stable than the primary standard by 3 orders of magnitude. Leapfrogging the currently held accuracy records of ion clocks, this work documents the first optical lattice clock to best all other atomic clock implementations, a mere 8 years after the first proof of principle experiments. In this thesis I will describe how we have overcome a number of important systematic uncertainties to achieve these results. This revolution in accuracy and precision opens the door for new experiments utilizing the clock as a probe of quantum many-body physics. To this end, a new apparatus has been designed that combines the unprecedented precision of clock experiments with the amazing progress attained in quantum gas experiments.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P