Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical Lattice Clock with Spin-1/2 Ytterbium Atoms

N. Lemke

Published Jan 1, 2012• 7 citations
OpenAlex

Abstract

An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.

Related papers

Hertz-Level Clock Spectroscopy of 171 Yb Atoms in a One-Dimensional Optical Lattice

Meng-Jiao Zhang, Hui Liu, Xi Zhang +4 more

An ultra-narrow spectroscopy of clock transition with high signal-to-noise ratio is crucial for a high-performance atomic optical clock. We present a detailed study about how to obtain a Hertz-level clock transition spectrum of 171 Yb atoms. About 4 × 10 4 atoms are loaded into a one-dimensional optical lattice with a magic wavelength of 759 nm, and a long lifetime of 3 s is realized with the lattice power of 1 W. Through normalized shelving detection and spin polarization, 171 Yb clock spectroscopy with a Fourier-limited linewidth of 5.9 Hz is obtained. Our work represents a key step toward an ytterbium optical clock with high frequency stability.

Chinese Physics Letters•Jul 1, 2016•7 citations

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

•May 23, 2018•0 citations

Development of an atomic frequency standard in the optical domain based on ultracold Ytterbium atoms

Marco Zoppi

The work described in this thesis was done at the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), in the optic division, within the Ph.D. of Metrology of the Politecnico di Torino. My work consisted in developing a new generation optical frequency standard based on Ytterbium atoms: the goal of this project is to realize a clock whose performance overcomes the ones of the standard which actually realizes the Second, the atomic Cesium fountain. This means realizes an apparatus which shows stability and accuracy better then the fountain ones: a possible way adopted in several new generation clock is using optical transitions, because they offer an higher quality factor of the clock transition itself, which means a better stability and the possibility to reach the 10^-17 level in the global accuracy of the clock. The fundamental idea of a clock is to realize as close as possible the basic idea under the actual definition of the Second, that is to fix the unit if time with a particular atomic transition, when the atom is completely unperturbed. Accomplishing this prescription means a lot of work in cooling down the atoms until the 10^-6 K regime using laser cooling techniques, developing a trap where atoms can be excited by the clock laser (the optical lattice) and of course a very careful frequency and amplitude stabilization of the clock laser itself is needed to reach our goal. The work described in this thesis regards the development of the two cooling stages of the Yb atoms and it is presented as follows. Chapter 1 explains with more details why an optical clock is needed to improve the accuracy of the actual realization of the Second, then describing the theoretical framework in which the clock will be developed. Chapter 2 contains a description of the experimental apparatus used, with more attention on the instrumentation related to the laser cooling of the atoms. Chapter 3 is about the characterization of the first cooling stage, both in a static and in a dynamic way, with some attention on the theoretical model developed to perform both the characterizations. Chapter 4 focuses on the development of the second cooling stage and it describes the actual state of the art of this stage

•Jan 1, 2012•0 citations

High Precision Spectroscopy of Strontium in an Optical Lattice: Towards a New Standard for Frequency and Time

Martin M. Boyd

Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise

•Jan 1, 2007•39 citations

Lattice-based optical clock using an even isotope of Yb

Zeb W. Barber, Chad Hoyt, J. E. Stalnaker +5 more

We describe progress toward an optical lattice clock based on an even isotope of Yb. The 1S0 → 3P0 clock resonance in 174Yb is accessed through a magnetically induced spectroscopic technique. Using ≈1mT static magnetic fields and ≈10 μW of probe light power we generate Rabi frequencies of several hertz. The narrow spectroscopic features that result (< 10 Hz FWHM) require a highly stabilized laser at the clock transition wavelength of 578 nm. We describe a new all solid-state laser system that shows hertz level stability. In order to cancel the slow drift of the cavity, spectroscopy is performed on the clock transition to provide feedback to the laser. Using a Ca neutral atom frequency standard as a reference oscillator,we show high stability and an effective method for investigating clock frequency shift systematics.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•3 citations

Spin- 1/2 Optical Lattice Clock

N. Lemke, Andrew D. Ludlow, Zeb W. Barber +7 more

We experimentally investigate an optical clock based on ;{171}Yb (I = 1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4 x 10;{-16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

arXiv:0906.1219•Physical Review Letters•Aug 3, 2009•281 citations
An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.
An ultra-narrow spectroscopy of clock transition with high signal-to-noise ratio is crucial for a high-performance atomic optical clock. We present a detailed study about how to obtain a Hertz-level clock transition spectrum of 171 Yb atoms. About 4 × 10 4 atoms are loaded into a one-dimensional optical lattice with a magic wavelength of 759 nm, and a long lifetime of 3 s is realized with the lattice power of 1 W. Through normalized shelving detection and spin polarization, 171 Yb clock spectroscopy with a Fourier-limited linewidth of 5.9 Hz is obtained. Our work represents a key step toward an ytterbium optical clock with high frequency stability.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
The work described in this thesis was done at the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), in the optic division, within the Ph.D. of Metrology of the Politecnico di Torino. My work consisted in developing a new generation optical frequency standard based on Ytterbium atoms: the goal of this project is to realize a clock whose performance overcomes the ones of the standard which actually realizes the Second, the atomic Cesium fountain. This means realizes an apparatus which shows stability and accuracy better then the fountain ones: a possible way adopted in several new generation clock is using optical transitions, because they offer an higher quality factor of the clock transition itself, which means a better stability and the possibility to reach the 10^-17 level in the global accuracy of the clock. The fundamental idea of a clock is to realize as close as possible the basic idea under the actual definition of the Second, that is to fix the unit if time with a particular atomic transition, when the atom is completely unperturbed. Accomplishing this prescription means a lot of work in cooling down the atoms until the 10^-6 K regime using laser cooling techniques, developing a trap where atoms can be excited by the clock laser (the optical lattice) and of course a very careful frequency and amplitude stabilization of the clock laser itself is needed to reach our goal. The work described in this thesis regards the development of the two cooling stages of the Yb atoms and it is presented as follows. Chapter 1 explains with more details why an optical clock is needed to improve the accuracy of the actual realization of the Second, then describing the theoretical framework in which the clock will be developed. Chapter 2 contains a description of the experimental apparatus used, with more attention on the instrumentation related to the laser cooling of the atoms. Chapter 3 is about the characterization of the first cooling stage, both in a static and in a dynamic way, with some attention on the theoretical model developed to perform both the characterizations. Chapter 4 focuses on the development of the second cooling stage and it describes the actual state of the art of this stage
Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise
We describe progress toward an optical lattice clock based on an even isotope of Yb. The 1S0 → 3P0 clock resonance in 174Yb is accessed through a magnetically induced spectroscopic technique. Using ≈1mT static magnetic fields and ≈10 μW of probe light power we generate Rabi frequencies of several hertz. The narrow spectroscopic features that result (< 10 Hz FWHM) require a highly stabilized laser at the clock transition wavelength of 578 nm. We describe a new all solid-state laser system that shows hertz level stability. In order to cancel the slow drift of the cavity, spectroscopy is performed on the clock transition to provide feedback to the laser. Using a Ca neutral atom frequency standard as a reference oscillator,we show high stability and an effective method for investigating clock frequency shift systematics.
We experimentally investigate an optical clock based on ;{171}Yb (I = 1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4 x 10;{-16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.