Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical lattice clock with an amplified laser diode

Stefano Condio

Published Oct 13, 2021• 0 citations
Publisher

Abstract

Master thesis in physics at University of Torino. ABSTRACT :Optical lattice clocks occupy a very important position in metrological research. Diffused worldwide, they are a strong candidate for a future redefinition of the second of the International System of Units (SI) and thanks to their extremely small fractional uncertainty about 10−18 they are involved in fundamental physics experiments, for example in the field of general relativity. In a optical clock, the lattice is used to trap ultracold atoms and it is realized with a retro-reflected laser tuned on magic wavelength to reduce perturbations on the clock transition. An optical lattice is generated usually starting by a titanium:sapphire laser: its main qualities are high output power and narrow linewidth, but it is delicate and difficult to use so its application in new kinds of atomic clocks, such as transportable or spacial, is not strongly recommended. Replacing it with an amplified laser diode would be preferable because these instruments are better for cost, reliability, size and weight, so suitable for applications out of laboratory, but at the same time present the problem of spectral purity as they have a not negligible amplified spontaneous emission (ASE): this phenomenon produces a broad spectrum detuned from magic wavelength inducing a perturbation on the clock transition. In my thesis I investigated experimentally the possibility to generate an optical lattice starting from an amplified laser diode emitting at 759.35 nm, ytterbium magic wavelength, and I applied the laser system that I developed on the atomic clock IT-Yb1 at Istituto Nazionale di Ricerca Metrologica (INRiM) located in Torino. The target of this work is to achieve fractional uncertainty due to ASE below 10−18, making the performances of the two different lasers sources equivalent. First, I calculated the theoretical model of the light shift induced by the lattice on the clock transition between ytterbium atomic states 1S0 →3 P0, comparing it with experimental results and I applied it to estimate ASE contribution to lattice shift. In the experimental part of this work I realized an optical system to study amplified laser diode emission and manipulate laser beam to obtain a good lattice from this laser source, filtering ASE with a volume Bragg grating and controlling power with an acousto optic modulator. Moreover I studied ASE spectral distribution in different conditions and its interaction with optical elements. Next studies foresee to measure experimentally with IT-Yb1 the shift induced by the laser system that I realized to calculate its uncertainty contribution and compare this result with the one obtained with a titanium:sapphire laser. This work will be useful to the development of compact or transportable atomic clocks based exclusively on semiconductor lasers with applications in the generation of optical timescales, travelling optical standards and the measurements of Earth gravitational redshift.

DOI
10.5281/zenodo.5566670

Related papers

Development of an atomic frequency standard in the optical domain based on ultracold Ytterbium atoms

Marco Zoppi

The work described in this thesis was done at the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), in the optic division, within the Ph.D. of Metrology of the Politecnico di Torino. My work consisted in developing a new generation optical frequency standard based on Ytterbium atoms: the goal of this project is to realize a clock whose performance overcomes the ones of the standard which actually realizes the Second, the atomic Cesium fountain. This means realizes an apparatus which shows stability and accuracy better then the fountain ones: a possible way adopted in several new generation clock is using optical transitions, because they offer an higher quality factor of the clock transition itself, which means a better stability and the possibility to reach the 10^-17 level in the global accuracy of the clock. The fundamental idea of a clock is to realize as close as possible the basic idea under the actual definition of the Second, that is to fix the unit if time with a particular atomic transition, when the atom is completely unperturbed. Accomplishing this prescription means a lot of work in cooling down the atoms until the 10^-6 K regime using laser cooling techniques, developing a trap where atoms can be excited by the clock laser (the optical lattice) and of course a very careful frequency and amplitude stabilization of the clock laser itself is needed to reach our goal. The work described in this thesis regards the development of the two cooling stages of the Yb atoms and it is presented as follows. Chapter 1 explains with more details why an optical clock is needed to improve the accuracy of the actual realization of the Second, then describing the theoretical framework in which the clock will be developed. Chapter 2 contains a description of the experimental apparatus used, with more attention on the instrumentation related to the laser cooling of the atoms. Chapter 3 is about the characterization of the first cooling stage, both in a static and in a dynamic way, with some attention on the theoretical model developed to perform both the characterizations. Chapter 4 focuses on the development of the second cooling stage and it describes the actual state of the art of this stage

•Jan 1, 2012•0 citations

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

•May 23, 2018•0 citations

Ytterbium optical lattice clock at INRIM

Marco Pizzocaro, Filippo Bregolin, Gianmaria Milani +5 more

We present an optical lattice clock based on ytterbium 171Yb atoms developed in the laboratories of INRIM. In the experiment, we cool and trap ytterbium atoms in a two stage magneto-optical trap (MOT) (at 399nm and 556nm for the first and second stage, respectively). Atoms are then transferred in a horizontal, one-dimensional optical lattice at the magic wavelength (759 nm). Here the clock transition at 578nm is probed by a laser stabilized on an ultra-stable cavity. We describe the generation of all the laser sources, the physic package and the operation of the clock. Lasers at 399 nm, 556nm and 578nm are obtained, with different techniques, using non-linear crystals starting from infrared sources. The clock laser is stabilized using a high finesse notched ULE cavity. The lattice is made with a titanium-sapphire laser. The aluminum vacuum chamber is designed for wide optical access and its temperature is measured by 8 thermistors for blackbody shift evaluation. Our system allows for fast loading of the lattice with 1 × 104atoms trapped in the lattice in 250 ms. We obtained preliminary spectroscopy results and we locked the clock laser to the atomic line. Future perspectives are discussed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•1 citation

Characterization and Suppression of Background Light Shifts in an Optical Lattice Clock

Robert Fasano, Yun-Jhih Chen, William F. McGrew +3 more

Experiments involving optical traps often require careful control of the ac Stark shifts induced by strong confining light fields. By carefully balancing light shifts between two atomic states of interest, optical traps at the magic wavelength have been especially effective at suppressing deleterious effects stemming from such shifts. Highlighting the power of this technique, optical clocks today exploit Lamb-Dicke confinement in magic-wavelength optical traps, in some cases realizing shift cancelation at the ten parts per billion level. Theory and empirical measurements can be used at varying levels of precision to determine the magic wavelength where shift cancelation occurs. However, lasers exhibit background spectra from amplified spontaneous emission or other lasing modes that can easily contaminate measurement of the magic wavelength and its reproducibility in other experiments or conditions. Indeed, residual light shifts from laser background have plagued optical lattice clock measurements for years. In this work, we develop a simple theoretical model allowing prediction of light shifts from measured background spectra. We demonstrate good agreement between this model and measurements of the background light shift from an amplified diode laser in a Yb optical lattice clock. Additionally, we model and experimentally characterize the filtering effect of a volume Bragg grating bandpass filter, demonstrating that application of the filter can reduce background light shifts from amplified spontaneous emission well below the ${10}^{\ensuremath{-}18}$ fractional clock frequency level. This demonstration is corroborated by direct clock comparisons between a filtered amplified diode laser and a filtered titanium:sapphire laser.

arXiv:2103.12052•Physical Review Applied•Apr 8, 2021•25 citations

Advancing Optical Lattice Clocks: Accurate Measurements on a Bosonic System and Development of a Hybrid Cavity-Lattice Clock

Juan Pablo Salvatierra

This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .

•May 27, 2026•0 citations

Experimental research on loading strontium bosons into the optical lattice operating at the “magic” wavelength

Tian Xiao, Wang Ye-Bing, Lu Ben-Quan +7 more

The optical lattice clock with neutral atoms occupies an outstanding position in the research field of atomic clocks, demonstrating the great potential of its performance (like the uncertainty and the stability). At present, the optical lattice clock has realized a 10-18 level of its uncertainty. In this paper, we present the realization of loading bosonic atoms 88Sr (strontium, alkaline-earth metals) into a one-dimensional (1D) optical lattice in our laboratory. The optical lattice where the atoms are trapped can make the energy level shift, called Stark shift. But there is the special optical lattice operating at the “magic” wavelength for clock transitions (5s2) 1S0-(5s5p) 3P0, which can make the same Stark light-shift for both of them, indicating a zero light-shift relative to the clock. In our experiment, Sr atoms are cooled in a two-stage cooling and its temperature can be as low as 2 μK. Then these cold atoms are confined in the Lamb-Dicke region by the lattice laser output from an amplified diode laser operating at the “magic” wavelength, 813 nm. Experimentally, it is straightforward to provide 850 mW of lattice power focused to a 38 μm beam radius. After the cold atoms have trapped in the optical lattice, the lifetime of atoms in 1D optical lattice is measured to be 270 ms. The temperature and the number are about 3.5 μK and 1.2×105 respectively. Besides, effects of the power of the lattice laser on both the number and temperature are analyzed. The number changes linearly with the laser power, while there is no obvious influence on the temperature by the power. This original and special approach for atoms trapped in the optical lattice can provide a long interrogation time for probing the clock transition. Furthermore, it may be the foundation for developing our optical lattice clock of strontium atoms.

Acta Physica Sinica•Jan 1, 2015•0 citations
Master thesis in physics at University of Torino. ABSTRACT :Optical lattice clocks occupy a very important position in metrological research. Diffused worldwide, they are a strong candidate for a future redefinition of the second of the International System of Units (SI) and thanks to their extremely small fractional uncertainty about 10−18 they are involved in fundamental physics experiments, for example in the field of general relativity. In a optical clock, the lattice is used to trap ultracold atoms and it is realized with a retro-reflected laser tuned on magic wavelength to reduce perturbations on the clock transition. An optical lattice is generated usually starting by a titanium:sapphire laser: its main qualities are high output power and narrow linewidth, but it is delicate and difficult to use so its application in new kinds of atomic clocks, such as transportable or spacial, is not strongly recommended. Replacing it with an amplified laser diode would be preferable because these instruments are better for cost, reliability, size and weight, so suitable for applications out of laboratory, but at the same time present the problem of spectral purity as they have a not negligible amplified spontaneous emission (ASE): this phenomenon produces a broad spectrum detuned from magic wavelength inducing a perturbation on the clock transition. In my thesis I investigated experimentally the possibility to generate an optical lattice starting from an amplified laser diode emitting at 759.35 nm, ytterbium magic wavelength, and I applied the laser system that I developed on the atomic clock IT-Yb1 at Istituto Nazionale di Ricerca Metrologica (INRiM) located in Torino. The target of this work is to achieve fractional uncertainty due to ASE below 10−18, making the performances of the two different lasers sources equivalent. First, I calculated the theoretical model of the light shift induced by the lattice on the clock transition between ytterbium atomic states 1S0 →3 P0, comparing it with experimental results and I applied it to estimate ASE contribution to lattice shift. In the experimental part of this work I realized an optical system to study amplified laser diode emission and manipulate laser beam to obtain a good lattice from this laser source, filtering ASE with a volume Bragg grating and controlling power with an acousto optic modulator. Moreover I studied ASE spectral distribution in different conditions and its interaction with optical elements. Next studies foresee to measure experimentally with IT-Yb1 the shift induced by the laser system that I realized to calculate its uncertainty contribution and compare this result with the one obtained with a titanium:sapphire laser. This work will be useful to the development of compact or transportable atomic clocks based exclusively on semiconductor lasers with applications in the generation of optical timescales, travelling optical standards and the measurements of Earth gravitational redshift.
The work described in this thesis was done at the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), in the optic division, within the Ph.D. of Metrology of the Politecnico di Torino. My work consisted in developing a new generation optical frequency standard based on Ytterbium atoms: the goal of this project is to realize a clock whose performance overcomes the ones of the standard which actually realizes the Second, the atomic Cesium fountain. This means realizes an apparatus which shows stability and accuracy better then the fountain ones: a possible way adopted in several new generation clock is using optical transitions, because they offer an higher quality factor of the clock transition itself, which means a better stability and the possibility to reach the 10^-17 level in the global accuracy of the clock. The fundamental idea of a clock is to realize as close as possible the basic idea under the actual definition of the Second, that is to fix the unit if time with a particular atomic transition, when the atom is completely unperturbed. Accomplishing this prescription means a lot of work in cooling down the atoms until the 10^-6 K regime using laser cooling techniques, developing a trap where atoms can be excited by the clock laser (the optical lattice) and of course a very careful frequency and amplitude stabilization of the clock laser itself is needed to reach our goal. The work described in this thesis regards the development of the two cooling stages of the Yb atoms and it is presented as follows. Chapter 1 explains with more details why an optical clock is needed to improve the accuracy of the actual realization of the Second, then describing the theoretical framework in which the clock will be developed. Chapter 2 contains a description of the experimental apparatus used, with more attention on the instrumentation related to the laser cooling of the atoms. Chapter 3 is about the characterization of the first cooling stage, both in a static and in a dynamic way, with some attention on the theoretical model developed to perform both the characterizations. Chapter 4 focuses on the development of the second cooling stage and it describes the actual state of the art of this stage
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
We present an optical lattice clock based on ytterbium 171Yb atoms developed in the laboratories of INRIM. In the experiment, we cool and trap ytterbium atoms in a two stage magneto-optical trap (MOT) (at 399nm and 556nm for the first and second stage, respectively). Atoms are then transferred in a horizontal, one-dimensional optical lattice at the magic wavelength (759 nm). Here the clock transition at 578nm is probed by a laser stabilized on an ultra-stable cavity. We describe the generation of all the laser sources, the physic package and the operation of the clock. Lasers at 399 nm, 556nm and 578nm are obtained, with different techniques, using non-linear crystals starting from infrared sources. The clock laser is stabilized using a high finesse notched ULE cavity. The lattice is made with a titanium-sapphire laser. The aluminum vacuum chamber is designed for wide optical access and its temperature is measured by 8 thermistors for blackbody shift evaluation. Our system allows for fast loading of the lattice with 1 × 104atoms trapped in the lattice in 250 ms. We obtained preliminary spectroscopy results and we locked the clock laser to the atomic line. Future perspectives are discussed.
Experiments involving optical traps often require careful control of the ac Stark shifts induced by strong confining light fields. By carefully balancing light shifts between two atomic states of interest, optical traps at the magic wavelength have been especially effective at suppressing deleterious effects stemming from such shifts. Highlighting the power of this technique, optical clocks today exploit Lamb-Dicke confinement in magic-wavelength optical traps, in some cases realizing shift cancelation at the ten parts per billion level. Theory and empirical measurements can be used at varying levels of precision to determine the magic wavelength where shift cancelation occurs. However, lasers exhibit background spectra from amplified spontaneous emission or other lasing modes that can easily contaminate measurement of the magic wavelength and its reproducibility in other experiments or conditions. Indeed, residual light shifts from laser background have plagued optical lattice clock measurements for years. In this work, we develop a simple theoretical model allowing prediction of light shifts from measured background spectra. We demonstrate good agreement between this model and measurements of the background light shift from an amplified diode laser in a Yb optical lattice clock. Additionally, we model and experimentally characterize the filtering effect of a volume Bragg grating bandpass filter, demonstrating that application of the filter can reduce background light shifts from amplified spontaneous emission well below the ${10}^{\ensuremath{-}18}$ fractional clock frequency level. This demonstration is corroborated by direct clock comparisons between a filtered amplified diode laser and a filtered titanium:sapphire laser.
This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .
The optical lattice clock with neutral atoms occupies an outstanding position in the research field of atomic clocks, demonstrating the great potential of its performance (like the uncertainty and the stability). At present, the optical lattice clock has realized a 10-18 level of its uncertainty. In this paper, we present the realization of loading bosonic atoms 88Sr (strontium, alkaline-earth metals) into a one-dimensional (1D) optical lattice in our laboratory. The optical lattice where the atoms are trapped can make the energy level shift, called Stark shift. But there is the special optical lattice operating at the “magic” wavelength for clock transitions (5s2) 1S0-(5s5p) 3P0, which can make the same Stark light-shift for both of them, indicating a zero light-shift relative to the clock. In our experiment, Sr atoms are cooled in a two-stage cooling and its temperature can be as low as 2 μK. Then these cold atoms are confined in the Lamb-Dicke region by the lattice laser output from an amplified diode laser operating at the “magic” wavelength, 813 nm. Experimentally, it is straightforward to provide 850 mW of lattice power focused to a 38 μm beam radius. After the cold atoms have trapped in the optical lattice, the lifetime of atoms in 1D optical lattice is measured to be 270 ms. The temperature and the number are about 3.5 μK and 1.2×105 respectively. Besides, effects of the power of the lattice laser on both the number and temperature are analyzed. The number changes linearly with the laser power, while there is no obvious influence on the temperature by the power. This original and special approach for atoms trapped in the optical lattice can provide a long interrogation time for probing the clock transition. Furthermore, it may be the foundation for developing our optical lattice clock of strontium atoms.