Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics Today

Building a better atomic clock

Benjamin Bloom

Published Jul 10, 2013• 4 citations
Publisher

Abstract

Since 1967, the Second has been defined by the CGPM as 9,192,631,770 periods of oscillation corresponding to a transition between two hyperfine levels in a Cesium atom with zero external fields. Key to this definition was the fact that as experimentalists found new and more precise ways to measure this frequency, the definition of the second would become more and more accurate with time. However, in the last 30 years, new technologies based on tunable lasers addressing optical transitions in atoms, ions, and molecules have offered an entirely new approach to defining the Second with significantly higher precision and accuracy. Here, I will show that by trapping thousands of atoms inside a specially engineered optical lattice one can create an extremely accurate frequency standard with 2 orders of magnitude improvement over current Cs standards. Furthermore, I will explain that standards based on this technology are fundamentally more stable than the primary standard by 3 orders of magnitude. Leapfrogging the currently held accuracy records of ion clocks, this work documents the first optical lattice clock to best all other atomic clock implementations, a mere 8 years after the first proof of principle experiments. In this thesis I will describe how we have overcome a number of important systematic uncertainties to achieve these results. This revolution in accuracy and precision opens the door for new experiments utilizing the clock as a probe of quantum many-body physics. To this end, a new apparatus has been designed that combines the unprecedented precision of clock experiments with the amazing progress attained in quantum gas experiments.

DOI
10.1063/pt.5.027159

Related papers

A New Generation of Atomic Clocks: Accuracy and Stability at the 10^{-18} Level

Benjamin Bloom, Travis Nicholson, Jason Williams +6 more

The exquisite control exhibited over quantum states of individual particles has revolutionized the field of precision measurement, as exemplified by the most accurate atomic clock realized in single trapped ions. Whereas many-atom lattice clocks have shown advantages in measurement precision over trapped-ion clocks, their accuracy has remained 20 times worse. Here we demonstrate, for the first time, that a many-atom system achieves accuracy (6x10^{-18}) better than a single ion-based clock, with vastly reduced averaging times (3000 s). This is the first time a single clock has achieved the best performance in all three key ingredients necessary for consideration as a primary standard - stability, reproducibility, and accuracy. This work paves the way for future experiments to integrate many-body quantum state engineering into the frontiers of quantum metrology, creating exciting opportunities to advance precision beyond the standard quantum limit. Improved frequency standards will have impact to a wide range of fields from the realization of the SI units, the development of quantum sensors, to precision tests of the fundamental laws of nature.

•Sep 4, 2013•10 citations

Improvements to a Strontium Optical Lattice Clock

Rees L. McNally

In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.

•Jan 1, 2014•0 citations

Development of an Apparatus for a Strontium Optical Lattice Optical Frequency Standard

Ian R. Hill

Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.

•Jun 1, 2012•3 citations

particular 'magic' wavelengths. This Review covers the experimental realizations of such clocks, the optimal design of optical lattices and recent demonstrations of improved stability for large numbers of atoms. Possible impacts and future applications of optical lattice clocks are also discussed, such as testing the fundamental laws of physics and developing relativistic geodesy.

Louis Essen

8half a century ago and have provided the definition of the second since 1967. The international atomic time (TAI) is currently kept by an ensemble of Cs clocks with a fractional uncertainty of Δν/ν0 ≈ 10 –15 , and some Cs fountain clocks 9,10 operate at even smaller uncertainties. Although Cs atomic clocks operate at the microwave transition of ν0 ≈ 9.2 GHz, using optical transition frequencies of several hundred terahertz should improve the fractional uncertainty Δν/ν0 by 4–5 orders of magnitude, as most measurement uncertainties Δν are independent of ν0 (except the Doppler shift Δ νD = (v/c)ν0, where v is the atomic velocity and c is the speed of light). The invention of the laser and the subsequent improvement of laser frequency stabilities 11 has allowed the realization of optical clocks to become a reality 2,3,12

•Jan 1, 2011•0 citations

Optical atomic clocks: defining the future of time and frequency metrology

Tara M. Fortier, Andre Nicholas Luiten, Helen S. Margolis

Optical atomic clocks based on laser-cooled trapped ions and atoms have advanced rapidly over the past decade. With fractional frequency uncertainties now surpassing 10 −18 , they are some of the most precise measurement tools ever built. Yet researchers are still pursuing new avenues of research to explore the fundamental limits to their stability, accuracy, and reproducibility. In this mini-review, we provide a survey of the current state of the art by describing the fundamental principles and techniques that underpin this progress, the architectures used to realize optical clocks, and the supporting laser technologies that are essential to their operation. We also examine the progress that has been made toward a redefinition of the second in the International System of Units and the inclusion of optical clocks into the global time and frequency metrology infrastructure. Finally, we discuss emerging applications of optical clocks and look at the prospects for making their precision more readily accessible to end users.

Optica•Dec 10, 2025•22 citations

Trapped-ion optical Atomic Clocks at the Quantum Limits

David R. Leibrandt, Samuel M. Brewer, Jwo-Sy Chen +4 more

Frequency and its inverse, time, are the most accurately measured quantities. Historically, improvements in the accuracy of clocks have enabled advances in navigation, communication, and science. Since 1967, the definition of the International System (SI) second has been based on the frequency of a microwave transition in cesium, and present day cesium atomic clocks have a fractional uncertainty near 10-16. Recently, a new type of atomic clock based on optical transitions has been developed, with a current fractional uncertainty near 10-18 (approximately one second divided by the age of the universe), and they are rapidly improving. This talk presents a brief summary of the development of optical atomic clocks, with a focus on the Al+ quantum-logic clock developed at NIST. We discuss the current state-of-the-art in optical clock performance, and describe new applications in sensing and fundamental physics. Future directions in optical atomic clock research are also considered.

Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting•Mar 7, 2017•2 citations
Since 1967, the Second has been defined by the CGPM as 9,192,631,770 periods of oscillation corresponding to a transition between two hyperfine levels in a Cesium atom with zero external fields. Key to this definition was the fact that as experimentalists found new and more precise ways to measure this frequency, the definition of the second would become more and more accurate with time. However, in the last 30 years, new technologies based on tunable lasers addressing optical transitions in atoms, ions, and molecules have offered an entirely new approach to defining the Second with significantly higher precision and accuracy. Here, I will show that by trapping thousands of atoms inside a specially engineered optical lattice one can create an extremely accurate frequency standard with 2 orders of magnitude improvement over current Cs standards. Furthermore, I will explain that standards based on this technology are fundamentally more stable than the primary standard by 3 orders of magnitude. Leapfrogging the currently held accuracy records of ion clocks, this work documents the first optical lattice clock to best all other atomic clock implementations, a mere 8 years after the first proof of principle experiments. In this thesis I will describe how we have overcome a number of important systematic uncertainties to achieve these results. This revolution in accuracy and precision opens the door for new experiments utilizing the clock as a probe of quantum many-body physics. To this end, a new apparatus has been designed that combines the unprecedented precision of clock experiments with the amazing progress attained in quantum gas experiments.
The exquisite control exhibited over quantum states of individual particles has revolutionized the field of precision measurement, as exemplified by the most accurate atomic clock realized in single trapped ions. Whereas many-atom lattice clocks have shown advantages in measurement precision over trapped-ion clocks, their accuracy has remained 20 times worse. Here we demonstrate, for the first time, that a many-atom system achieves accuracy (6x10^{-18}) better than a single ion-based clock, with vastly reduced averaging times (3000 s). This is the first time a single clock has achieved the best performance in all three key ingredients necessary for consideration as a primary standard - stability, reproducibility, and accuracy. This work paves the way for future experiments to integrate many-body quantum state engineering into the frontiers of quantum metrology, creating exciting opportunities to advance precision beyond the standard quantum limit. Improved frequency standards will have impact to a wide range of fields from the realization of the SI units, the development of quantum sensors, to precision tests of the fundamental laws of nature.
In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.
8half a century ago and have provided the definition of the second since 1967. The international atomic time (TAI) is currently kept by an ensemble of Cs clocks with a fractional uncertainty of Δν/ν0 ≈ 10 –15 , and some Cs fountain clocks 9,10 operate at even smaller uncertainties. Although Cs atomic clocks operate at the microwave transition of ν0 ≈ 9.2 GHz, using optical transition frequencies of several hundred terahertz should improve the fractional uncertainty Δν/ν0 by 4–5 orders of magnitude, as most measurement uncertainties Δν are independent of ν0 (except the Doppler shift Δ νD = (v/c)ν0, where v is the atomic velocity and c is the speed of light). The invention of the laser and the subsequent improvement of laser frequency stabilities 11 has allowed the realization of optical clocks to become a reality 2,3,12
Optical atomic clocks based on laser-cooled trapped ions and atoms have advanced rapidly over the past decade. With fractional frequency uncertainties now surpassing 10 −18 , they are some of the most precise measurement tools ever built. Yet researchers are still pursuing new avenues of research to explore the fundamental limits to their stability, accuracy, and reproducibility. In this mini-review, we provide a survey of the current state of the art by describing the fundamental principles and techniques that underpin this progress, the architectures used to realize optical clocks, and the supporting laser technologies that are essential to their operation. We also examine the progress that has been made toward a redefinition of the second in the International System of Units and the inclusion of optical clocks into the global time and frequency metrology infrastructure. Finally, we discuss emerging applications of optical clocks and look at the prospects for making their precision more readily accessible to end users.
Frequency and its inverse, time, are the most accurately measured quantities. Historically, improvements in the accuracy of clocks have enabled advances in navigation, communication, and science. Since 1967, the definition of the International System (SI) second has been based on the frequency of a microwave transition in cesium, and present day cesium atomic clocks have a fractional uncertainty near 10-16. Recently, a new type of atomic clock based on optical transitions has been developed, with a current fractional uncertainty near 10-18 (approximately one second divided by the age of the universe), and they are rapidly improving. This talk presents a brief summary of the development of optical atomic clocks, with a focus on the Al+ quantum-logic clock developed at NIST. We discuss the current state-of-the-art in optical clock performance, and describe new applications in sensing and fundamental physics. Future directions in optical atomic clock research are also considered.