Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

Published May 23, 2018• 0 citations
Publisher

Abstract

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

DOI
10.6092/polito/porto/2708557

Related papers

Development of an Apparatus for a Strontium Optical Lattice Optical Frequency Standard

Ian R. Hill

Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.

•Jun 1, 2012•3 citations

Spectroscopy schemes for improved optical clock stability

Filip Butuc-Mayer

Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.

•Jan 1, 2026•0 citations

particular 'magic' wavelengths. This Review covers the experimental realizations of such clocks, the optimal design of optical lattices and recent demonstrations of improved stability for large numbers of atoms. Possible impacts and future applications of optical lattice clocks are also discussed, such as testing the fundamental laws of physics and developing relativistic geodesy.

Louis Essen

8half a century ago and have provided the definition of the second since 1967. The international atomic time (TAI) is currently kept by an ensemble of Cs clocks with a fractional uncertainty of Δν/ν0 ≈ 10 –15 , and some Cs fountain clocks 9,10 operate at even smaller uncertainties. Although Cs atomic clocks operate at the microwave transition of ν0 ≈ 9.2 GHz, using optical transition frequencies of several hundred terahertz should improve the fractional uncertainty Δν/ν0 by 4–5 orders of magnitude, as most measurement uncertainties Δν are independent of ν0 (except the Doppler shift Δ νD = (v/c)ν0, where v is the atomic velocity and c is the speed of light). The invention of the laser and the subsequent improvement of laser frequency stabilities 11 has allowed the realization of optical clocks to become a reality 2,3,12

•Jan 1, 2011•0 citations

An optical lattice clock with neutral strontium

Richard Hobson

Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.

•Jan 1, 2016•9 citations

Improving lattice-light-shift uncertainty of an 171Yb optical clock with optimized cooling and trapping lasers

Chengquan Peng, Tao Zhang, Changyue Sun +7 more

Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.

Applied Physics Letters•Sep 9, 2024•2 citations

First optical lattice frequency standard based on 24Mg atoms

Dominika Fim

The primary frequency and time standard, defined via a transition frequency of caesium-133, is realized by microwave clocks reaching relative uncertainties in the 10−^16 level. This performance has been surpassed by state-of-the-art lattice clocks, with transition frequencies in the optical regime, leading to two orders of magnitude lower uncertainties. The key to this performance is the confinement in the Lamb-Dicke regime at the magic wavelength enabling a Doppler- and recoil-free spectroscopy with a first-order suppressed AC Stark shift. In atomic clocks, several effects contribute to the uncertainty of the transition frequency. Through continuous global characterization efforts, the individual uncertainty of these effects have been subsequently reduced. Yet one effect, namely the frequency shift induced by blackbody radiation has been identified as a dominant contribution which is difficult to overcome by technical means. In this regard, magnesium-24 excels as a species of choice as its blackbody radiation sensitivity is one order of magnitude lower than in the most frequently used atomic clock species. Furthermore, magnesium offers a relatively simple electronic structure which enables theoretical support through high-precision calculations. This thesis features the first characterization of a magnesium optical lattice clock operating at the magic wavelength. The characterization of the magnesium frequency standard presented in this thesis depends essentially on the resolution of the transition linewidth, which could be reduced from kHz range to 51(3) Hz in a complementing work. The realization of a transition linewidth with a quality factor of Q = 1.3 × 10^13 has contributed to an improved determination of the magic wavelength within this thesis to 468.4106(2) nm. Compared to earlier work, this represents an improvement of two orders of magnitude. Furthermore, the lower transition linewidth also allowed the first observation of the probe AC Stark shift and thus the first characterization of effects in the lattice that falsify the frequency of the trapped magnesium atoms. Overall, the relative uncertainty of the frequency-related effects influencing the clock transition could be determined to be 7.1 × 10^−15. The dominant contributions can be assigned to tunneling broadening and the lattice and probe AC Stark effects, induced by the probe and lattice light. All these effects can be traced back to technical limitations and are part of future work. Following the characterization, a first frequency comparison between the magnesium lattice clock against the primary frequency standard as well as the ytterbium ion clock at the PTB has been performed and thus a first realization of a lattice based frequency standard with magnesium atoms was demonstrated. The determined transition frequency of 655 058 646 681 864.1(5.3) Hz complies with former measurements. The primary frequency and time standard, defined via a transition frequency of caesium-133, is realized by microwave clocks reaching relative uncertainties in the 10^−16 level. This performance has been surpassed by state-of-the-art lattice clocks, with transition frequencies in the optical regime, leading to two orders of magnitude lower uncertainties. The key to this performance is the confinement in the Lamb-Dicke regime at the magic wavelength enabling a Doppler- and recoil-free spectroscopy with a first-order suppressed AC Stark shift. In atomic clocks, several effects contribute to the uncertainty of the transition frequency. Through continuous global characterization efforts, the individual uncertainty of these effects have been subsequently reduced. Yet one effect, namely the frequency shift induced by blackbody radiation has been identified as a dominant contribution which is difficult to overcome by technical means. In this regard, magnesium-24 excels as a species of choice as its blackbody radiation sensitivity is one order of magnitude lower than in the most frequently used atomic clock species. Furthermore, magnesium offers a relatively simple electronic structure which enables theoretical support through high-precision calculations. This thesis features the first characterization of a magnesium optical lattice clock operating at the magic wavelength. The characterization of the magnesium frequency standard presented in this thesis depends essentially on the resolution of the transition linewidth, which could be reduced from kHz range to 51(3) Hz in a complementing work. The realization of a transition linewidth with a quality factor of Q = 1.3 × 10^13 has contributed to an improved determination of the magic wavelength within this thesis to 468.4106(2) nm. Compared to earlier work, this represents an improvement of two orders of magnitude. Furthermore, the lower transition linewidth also allowed the first observation of the probe AC Stark shift and thus the first characterization of effects in the lattice that falsify the frequency of the trapped magnesium atoms. Overall, the relative uncertainty of the frequency-related effects influencing the clock transition could be determined to be 7.1 × 10^−15. The dominant contributions can be assigned to tunneling broadening and the lattice and probe AC Stark effects, induced by the probe and lattice light. All these effects can be traced back to technical limitations and are part of future work. Following the characterization, a first frequency comparison between the magnesium lattice clock against the primary frequency standard as well as the ytterbium ion clock at the PTB has been performed and thus a first realization of a lattice based frequency standard with magnesium atoms was demonstrated. The determined transition frequency of 655 058 646 681 864.1(5.3) Hz complies with former measurements.

•Jan 1, 2021•2 citations
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.
8half a century ago and have provided the definition of the second since 1967. The international atomic time (TAI) is currently kept by an ensemble of Cs clocks with a fractional uncertainty of Δν/ν0 ≈ 10 –15 , and some Cs fountain clocks 9,10 operate at even smaller uncertainties. Although Cs atomic clocks operate at the microwave transition of ν0 ≈ 9.2 GHz, using optical transition frequencies of several hundred terahertz should improve the fractional uncertainty Δν/ν0 by 4–5 orders of magnitude, as most measurement uncertainties Δν are independent of ν0 (except the Doppler shift Δ νD = (v/c)ν0, where v is the atomic velocity and c is the speed of light). The invention of the laser and the subsequent improvement of laser frequency stabilities 11 has allowed the realization of optical clocks to become a reality 2,3,12
Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.
Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.
The primary frequency and time standard, defined via a transition frequency of caesium-133, is realized by microwave clocks reaching relative uncertainties in the 10−^16 level. This performance has been surpassed by state-of-the-art lattice clocks, with transition frequencies in the optical regime, leading to two orders of magnitude lower uncertainties. The key to this performance is the confinement in the Lamb-Dicke regime at the magic wavelength enabling a Doppler- and recoil-free spectroscopy with a first-order suppressed AC Stark shift. In atomic clocks, several effects contribute to the uncertainty of the transition frequency. Through continuous global characterization efforts, the individual uncertainty of these effects have been subsequently reduced. Yet one effect, namely the frequency shift induced by blackbody radiation has been identified as a dominant contribution which is difficult to overcome by technical means. In this regard, magnesium-24 excels as a species of choice as its blackbody radiation sensitivity is one order of magnitude lower than in the most frequently used atomic clock species. Furthermore, magnesium offers a relatively simple electronic structure which enables theoretical support through high-precision calculations. This thesis features the first characterization of a magnesium optical lattice clock operating at the magic wavelength. The characterization of the magnesium frequency standard presented in this thesis depends essentially on the resolution of the transition linewidth, which could be reduced from kHz range to 51(3) Hz in a complementing work. The realization of a transition linewidth with a quality factor of Q = 1.3 × 10^13 has contributed to an improved determination of the magic wavelength within this thesis to 468.4106(2) nm. Compared to earlier work, this represents an improvement of two orders of magnitude. Furthermore, the lower transition linewidth also allowed the first observation of the probe AC Stark shift and thus the first characterization of effects in the lattice that falsify the frequency of the trapped magnesium atoms. Overall, the relative uncertainty of the frequency-related effects influencing the clock transition could be determined to be 7.1 × 10^−15. The dominant contributions can be assigned to tunneling broadening and the lattice and probe AC Stark effects, induced by the probe and lattice light. All these effects can be traced back to technical limitations and are part of future work. Following the characterization, a first frequency comparison between the magnesium lattice clock against the primary frequency standard as well as the ytterbium ion clock at the PTB has been performed and thus a first realization of a lattice based frequency standard with magnesium atoms was demonstrated. The determined transition frequency of 655 058 646 681 864.1(5.3) Hz complies with former measurements. The primary frequency and time standard, defined via a transition frequency of caesium-133, is realized by microwave clocks reaching relative uncertainties in the 10^−16 level. This performance has been surpassed by state-of-the-art lattice clocks, with transition frequencies in the optical regime, leading to two orders of magnitude lower uncertainties. The key to this performance is the confinement in the Lamb-Dicke regime at the magic wavelength enabling a Doppler- and recoil-free spectroscopy with a first-order suppressed AC Stark shift. In atomic clocks, several effects contribute to the uncertainty of the transition frequency. Through continuous global characterization efforts, the individual uncertainty of these effects have been subsequently reduced. Yet one effect, namely the frequency shift induced by blackbody radiation has been identified as a dominant contribution which is difficult to overcome by technical means. In this regard, magnesium-24 excels as a species of choice as its blackbody radiation sensitivity is one order of magnitude lower than in the most frequently used atomic clock species. Furthermore, magnesium offers a relatively simple electronic structure which enables theoretical support through high-precision calculations. This thesis features the first characterization of a magnesium optical lattice clock operating at the magic wavelength. The characterization of the magnesium frequency standard presented in this thesis depends essentially on the resolution of the transition linewidth, which could be reduced from kHz range to 51(3) Hz in a complementing work. The realization of a transition linewidth with a quality factor of Q = 1.3 × 10^13 has contributed to an improved determination of the magic wavelength within this thesis to 468.4106(2) nm. Compared to earlier work, this represents an improvement of two orders of magnitude. Furthermore, the lower transition linewidth also allowed the first observation of the probe AC Stark shift and thus the first characterization of effects in the lattice that falsify the frequency of the trapped magnesium atoms. Overall, the relative uncertainty of the frequency-related effects influencing the clock transition could be determined to be 7.1 × 10^−15. The dominant contributions can be assigned to tunneling broadening and the lattice and probe AC Stark effects, induced by the probe and lattice light. All these effects can be traced back to technical limitations and are part of future work. Following the characterization, a first frequency comparison between the magnesium lattice clock against the primary frequency standard as well as the ytterbium ion clock at the PTB has been performed and thus a first realization of a lattice based frequency standard with magnesium atoms was demonstrated. The determined transition frequency of 655 058 646 681 864.1(5.3) Hz complies with former measurements.