Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Quantum Electronics Conference (EQEC)

Single-atom detection by micro-cavities

Péter Horák, Bruce G. Klappauf, Peter G. Kazansky

Published Jan 1, 2003• 0 citations
Publisher

Abstract

Possibilities of integrating micro-optics on top of an atom chip by standard fiber technology are investigated. In particular, the study is interested in single-atom detection with minimal spontaneous scattering.
DOI
10.1109/eqec.2003.1314171

Related papers

Possibility of single-atom detection on a chip

Péter Horák, Bruce G. Klappauf, Albrecht Haase +4 more

We investigate the optical detection of single atoms held in a microscopic atom trap close to a surface. Laser light is guided by optical fibers or optical microstructures via the atom to a photodetector. Our results suggest that with present-day technology microcavities can be built around the atom with sufficiently high finesse to permit unambiguous detection of a single atom in the trap with $10\ensuremath{\mu}\mathrm{s}$ of integration. We compare resonant and nonresonant detection schemes and discuss the requirements for detecting an atom without causing it to undergo spontaneous emission.

arXiv:quant-ph/0210090•Physical Review A•Apr 11, 2003•95 citations

Fibre optics for atom detection

Steve Helsby, Péter Horák, Peter G. Kazansky

The paper reports on standard fibre optical components mounted onto the chip for single atom detection. At present, two main directions are being pursued: fluorescence detection and fibre Fabry-Perot gap cavities. Theoretical analysis has shown that both devices will have the ability to detect single atoms with the micro-cavities offering the possibility of non-destructive detection.

European Quantum Electronics Conference (EQEC)•Jan 18, 2006•0 citations

Fiber optics for quantum computers

Steve Helsby, Hebe Powell, Péter Horák +2 more

Abstract: We describe schemes for the integration of miniature optical components onto Atom Chips, for the manipulation and detection of ultra-cold atoms. Our intention is to build detectors sensitive enough to accurately detect single atoms. Two approaches are discussed: simple fluorescence detection and the use of a resonant cavity. Theory predicts that cavities with F>100 should be sufficient to obtain signal to noise ratios high enough to detect single atoms. The first micro cavities were demonstrated using mirrors formed by cleaved fiber ends coated with a stick-on dielectric coating to give F ∼100. A more successful approach involves the full integration of the mirrors and fibers by using Bragg gratings written into the fiber core: it has been possible to form gap cavities with F ~ 150. 1.

•Jan 1, 2004•0 citations

Integration of a tunable optical micro-cavity for single atom detection on an atom chip

Carsten Gollasch, Z. Moktadir, G. Lewis +4 more

Recent experiments demonstrated single-atom detection using microscopic optical cavities. Here we present an optical micro-cavity whose length can be tuned using an electrostatic comb-drive. This design is suitable for integration into a silicon atom chip.

Quantum Electronics and Laser Science Conference•May 1, 2007•0 citations

Microcavities on atom chips for single-atom detection

Albrecht Haase, Michael Schwarz, Marco Wilzbach +5 more

To demonstrate the feasibility of detecting magnetically trapped neutral atoms with "bad" cavities, a macroscopic nearly concentric cavity is built. Using this cavity,atoms guided with a free-standing current-carrying wire are detected.

European Quantum Electronics Conference (EQEC)•Jan 18, 2006•0 citations

Single atom detection on an atom chip with integrated optics

Marco Wilzbach

The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.

•Jan 1, 2007•0 citations
We investigate the optical detection of single atoms held in a microscopic atom trap close to a surface. Laser light is guided by optical fibers or optical microstructures via the atom to a photodetector. Our results suggest that with present-day technology microcavities can be built around the atom with sufficiently high finesse to permit unambiguous detection of a single atom in the trap with $10\ensuremath{\mu}\mathrm{s}$ of integration. We compare resonant and nonresonant detection schemes and discuss the requirements for detecting an atom without causing it to undergo spontaneous emission.
Abstract: We describe schemes for the integration of miniature optical components onto Atom Chips, for the manipulation and detection of ultra-cold atoms. Our intention is to build detectors sensitive enough to accurately detect single atoms. Two approaches are discussed: simple fluorescence detection and the use of a resonant cavity. Theory predicts that cavities with F>100 should be sufficient to obtain signal to noise ratios high enough to detect single atoms. The first micro cavities were demonstrated using mirrors formed by cleaved fiber ends coated with a stick-on dielectric coating to give F ∼100. A more successful approach involves the full integration of the mirrors and fibers by using Bragg gratings written into the fiber core: it has been possible to form gap cavities with F ~ 150. 1.
The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.