Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE International Instrumentation and Measurement Technology Conference

Spatial-Light-Modulator-Based Axial Energy- Shaping Optimization Method for Probe Light in SERF Atomic Magnetometers

Fangzhou Ling, Xiujie Fang, Kun CHEN, Yueshen Wang, Jiayi Wei, Xin Xu, Bangcheng Han, Danyue Ma

Published May 1, 2026• 0 citations
Publisher

Abstract

This paper proposes a wavefront-shaping approach for weak magnetic-field detection in spin-exchangerelaxation-free (SERF) atomic magnetometers. A spatial light modulator (SLM) is employed to tailor the axial energy distribution of the probe beam inside the vapor cell, aiming to enhance the effective sensitivity to ultra-weak magneto-optical rotation signals. In near-resonant SERF operation, the probe beam undergoes non-negligible absorption along propagation, while the atomic spin polarization typically exhibits a “low–highextensible route to improving thelow” longitudinal profile. Motivated by this mismatch, we programmatically design the incident wavefront so that the incell probe intensity follows a similar “low–high–low” axial distribution, thereby maximizing the path-integrated Faraday rotation under a fixed photon budget. Theoretical modeling and numerical simulations show that, compared with a uniformly incident Gaussian probe, the wavefront-shaped probe can increase the path-integrated rotation signal by up to ~30% without increasing optical power. To provide experimental evidence that spatial intensity engineering of the probe directly impacts the readout chain, we further perform a proof-of-concept transverse validation experiment by comparing Gaussian and flat-top probes generated using a beam-homogenizing waveplate. Under matched probe spot size, sensitivity spectra are measured at probe powers of 2, 4, 6, 8, and 10 mW. Across all tested powers, the flat-top probe consistently reduces the band-averaged sensitivity over 20–45 Hz by approximately 8%–17% relative to the Gaussian probe, indicating a lower effective noise floor and improved readout signal-to-noise ratio. These results support spatial beam shaping as a feasible and extensible route to improving the signal-to-noise ratio and effective sensitivity of SERF atomic magnetometers for ultra-weak magnetic-field measurements.

DOI
10.1109/i2mtc66907.2026.11694704

Related papers

Structured light improves the sensitivity of SERF magnetometry via weak measurement

Feiyun Fang, Zhaoying Wang, Qiang Lin

This Letter presents what we believe to be a novel approach to enhance the sensitivity of spin-exchange-relaxation-free (SERF) atomic magnetometry by integrating a structured light combined with weak measurement. This strategy may address the limitations of detecting minute transverse magnetic fields due to low signal-to-noise ratios (SNR). We employ a Laguerre–Gaussian (LG) beam with tunable topological charge to amplify magneto-optical rotation (MOR) signals via weak measurement. We find that under a fixed magnetic field, the output polarization rotation angle monotonically increases as a function of the topological charges l . Furthermore, we experimentally demonstrate a 1.5 times signal enhancement using LG beams compared with Gaussian beams, achieving much better sensitivity. The results pave way for applications of structured light in ultra-sensitive atomic magnetometry.

Optics Letters•Oct 1, 2025•3 citations

High spatial resolution multi-channel optically pumped atomic magnetometer based on a spatial light modulator

Xiujie Fang, Kai Wei, Tian Zhao +5 more

Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.

Optics Express•Aug 14, 2020•48 citations

Performance optimization of a SERF atomic magnetometer based on flat-top light beam

Ziqi Yuan, Junjian Tang, Shudong 树东 Lin 林 +1 more

We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spin-exchange relaxation-free (SERF) atomic magnetometers (AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped (FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.

Chinese Physics B•Apr 18, 2024•5 citations

Impact of Three-Dimensional Beam-Splitting Light Fields on SERF Polarization and Light-Shift Noise

Jiayi Wei, Xiujie Fang, Xinxiu Zhou +5 more

This paper investigates the impact of pump-beam spatial shaping on spin-polarization uniformity and light-shiftrelated instability in spin-exchange relaxation-free (SERF) atomic magnetometers. Three representative pump profiles—a single Gaussian beam, a flat-top beam, and a split-beam configuration—are studied by combining a steady-state Bloch model with diffusion and a three-dimensional evaluation of the AC-Stark-shift-induced fictitious magnetic field. Simulations show that the Gaussian beam produces strong center-localized pumping with pronounced transverse/longitudinal gradients, whereas the flat-top beam improves transverse uniformity but decays faster along the propagation direction and tends to maintain a larger absolute light shift. By redistributing optical power into multiple beamlets and leveraging diffusion-driven smoothing, split-beam pumping yields a flatter polarization distribution, achieving the smallest depth-averaged polarization non-uniformity among the three cases, and mitigates the spatial inhomogeneity of$B_{\text{LS}}$by suppressing peak intensity. Experimental validation on a SERF platform is performed using an SLM-generated 2 × 2 beamlet array under identical total incident pump power. Frequency-response measurements at$z=0$and$z= \pm 5 ~\text{mm}$demonstrate improved longitudinal response uniformity, and noise-floor measurements in the$20-40 ~\text{Hz}$band exhibit a lower level with weaker$z$dependence, consistent with reduced light-shift-induced noise. The results indicate that split-beam pumping provides an effective and experimentally accessible route to balancing polarization uniformity and light-shift stability in SERF magnetometers.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2026•0 citations

Biaxial zero-field atomic magnetometer with a multi-passed probe light

Yibo Qi, Shuying Wang, Nuozhou Xu +3 more

Multi-passed probe light can enhance the signal of atomic magnetometers by increasing the effective optical path length between the alkali metal atomic ensemble and the probe light, thereby strengthening the sensitivity. In recent years, multi-passed probe light has become an important method for improving the response signal and sensitivity of atomic magnetometers. To achieve biaxial magnetic field measurement while maintaining high sensitivity, a biaxial measurement spin-exchange relaxation-free (SERF) atomic magnetometer with a multi-passed probe light is proposed in this paper. The theoretical model and experimental advantages of using multi-passed probe light in longitudinal magnetic field modulation (Z-mode) SERF atomic magnetometers are analyzed. In this paper, a new model of output response of the Z-mode SERF atomic magnetometer based on multi-passed probe light is established, a compact reflective optical path is designed to increase the optical path between the probe light and the polarized alkali metal atomic ensemble, enhance the signal response, and achieve the suppression of low-frequency 1/f noise through longitudinal magnetic field modulation. Experimental results confirmed that the magnetic field sensitivity in the x- and y-axis of the multi-passed probe light configuration improved by 29% and 18%, respectively, compared to the single-pass configuration.

Optics Young Scientist Summit (OYSS)•Jan 22, 2025•0 citations

Inverse weak measurement in a SERF magnetometer

Qian Cao, Liang Xu, Ziqian Yue +2 more

Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.

arXiv:2508.12306•Photonics Research•Oct 27, 2025•5 citations
This paper proposes a wavefront-shaping approach for weak magnetic-field detection in spin-exchangerelaxation-free (SERF) atomic magnetometers. A spatial light modulator (SLM) is employed to tailor the axial energy distribution of the probe beam inside the vapor cell, aiming to enhance the effective sensitivity to ultra-weak magneto-optical rotation signals. In near-resonant SERF operation, the probe beam undergoes non-negligible absorption along propagation, while the atomic spin polarization typically exhibits a “low–highextensible route to improving thelow” longitudinal profile. Motivated by this mismatch, we programmatically design the incident wavefront so that the incell probe intensity follows a similar “low–high–low” axial distribution, thereby maximizing the path-integrated Faraday rotation under a fixed photon budget. Theoretical modeling and numerical simulations show that, compared with a uniformly incident Gaussian probe, the wavefront-shaped probe can increase the path-integrated rotation signal by up to ~30% without increasing optical power. To provide experimental evidence that spatial intensity engineering of the probe directly impacts the readout chain, we further perform a proof-of-concept transverse validation experiment by comparing Gaussian and flat-top probes generated using a beam-homogenizing waveplate. Under matched probe spot size, sensitivity spectra are measured at probe powers of 2, 4, 6, 8, and 10 mW. Across all tested powers, the flat-top probe consistently reduces the band-averaged sensitivity over 20–45 Hz by approximately 8%–17% relative to the Gaussian probe, indicating a lower effective noise floor and improved readout signal-to-noise ratio. These results support spatial beam shaping as a feasible and extensible route to improving the signal-to-noise ratio and effective sensitivity of SERF atomic magnetometers for ultra-weak magnetic-field measurements.
This Letter presents what we believe to be a novel approach to enhance the sensitivity of spin-exchange-relaxation-free (SERF) atomic magnetometry by integrating a structured light combined with weak measurement. This strategy may address the limitations of detecting minute transverse magnetic fields due to low signal-to-noise ratios (SNR). We employ a Laguerre–Gaussian (LG) beam with tunable topological charge to amplify magneto-optical rotation (MOR) signals via weak measurement. We find that under a fixed magnetic field, the output polarization rotation angle monotonically increases as a function of the topological charges l . Furthermore, we experimentally demonstrate a 1.5 times signal enhancement using LG beams compared with Gaussian beams, achieving much better sensitivity. The results pave way for applications of structured light in ultra-sensitive atomic magnetometry.
Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.
We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spin-exchange relaxation-free (SERF) atomic magnetometers (AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped (FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.
This paper investigates the impact of pump-beam spatial shaping on spin-polarization uniformity and light-shiftrelated instability in spin-exchange relaxation-free (SERF) atomic magnetometers. Three representative pump profiles—a single Gaussian beam, a flat-top beam, and a split-beam configuration—are studied by combining a steady-state Bloch model with diffusion and a three-dimensional evaluation of the AC-Stark-shift-induced fictitious magnetic field. Simulations show that the Gaussian beam produces strong center-localized pumping with pronounced transverse/longitudinal gradients, whereas the flat-top beam improves transverse uniformity but decays faster along the propagation direction and tends to maintain a larger absolute light shift. By redistributing optical power into multiple beamlets and leveraging diffusion-driven smoothing, split-beam pumping yields a flatter polarization distribution, achieving the smallest depth-averaged polarization non-uniformity among the three cases, and mitigates the spatial inhomogeneity ofBLSB_{\text{LS}}BLS​by suppressing peak intensity. Experimental validation on a SERF platform is performed using an SLM-generated 2 × 2 beamlet array under identical total incident pump power. Frequency-response measurements atz=0z=0z=0andz=±5 mmz= \pm 5 ~\text{mm}z=±5 mmdemonstrate improved longitudinal response uniformity, and noise-floor measurements in the20−40 Hz20-40 ~\text{Hz}20−40 Hzband exhibit a lower level with weakerzzzdependence, consistent with reduced light-shift-induced noise. The results indicate that split-beam pumping provides an effective and experimentally accessible route to balancing polarization uniformity and light-shift stability in SERF magnetometers.
Multi-passed probe light can enhance the signal of atomic magnetometers by increasing the effective optical path length between the alkali metal atomic ensemble and the probe light, thereby strengthening the sensitivity. In recent years, multi-passed probe light has become an important method for improving the response signal and sensitivity of atomic magnetometers. To achieve biaxial magnetic field measurement while maintaining high sensitivity, a biaxial measurement spin-exchange relaxation-free (SERF) atomic magnetometer with a multi-passed probe light is proposed in this paper. The theoretical model and experimental advantages of using multi-passed probe light in longitudinal magnetic field modulation (Z-mode) SERF atomic magnetometers are analyzed. In this paper, a new model of output response of the Z-mode SERF atomic magnetometer based on multi-passed probe light is established, a compact reflective optical path is designed to increase the optical path between the probe light and the polarized alkali metal atomic ensemble, enhance the signal response, and achieve the suppression of low-frequency 1/f noise through longitudinal magnetic field modulation. Experimental results confirmed that the magnetic field sensitivity in the x- and y-axis of the multi-passed probe light configuration improved by 29% and 18%, respectively, compared to the single-pass configuration.
Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.