Optics Letters

Structured light improves the sensitivity of SERF magnetometry via weak measurement

Feiyun Fang, Zhaoying Wang, Qiang Lin

Published Oct 1, 2025• 3 citations
Publisher

Abstract

This Letter presents what we believe to be a novel approach to enhance the sensitivity of spin-exchange-relaxation-free (SERF) atomic magnetometry by integrating a structured light combined with weak measurement. This strategy may address the limitations of detecting minute transverse magnetic fields due to low signal-to-noise ratios (SNR). We employ a Laguerre–Gaussian (LG) beam with tunable topological charge to amplify magneto-optical rotation (MOR) signals via weak measurement. We find that under a fixed magnetic field, the output polarization rotation angle monotonically increases as a function of the topological charges l . Furthermore, we experimentally demonstrate a 1.5 times signal enhancement using LG beams compared with Gaussian beams, achieving much better sensitivity. The results pave way for applications of structured light in ultra-sensitive atomic magnetometry.

DOI
10.1364/ol.573716

Related papers

Structured-Light Magnetometry in a Coherently Controlled Atomic Medium

Parkhi Bhardwaj, Shubhrangshu Dasgupta

A structured-light-based approach to magneto-optical rotation (MOR) magnetometry is proposed, in which magnetically induced polarization rotation is converted into a directly observable spatial displacement. A radially polarized Laguerre--Gaussian beam propagating through cold $^{87}\mathrm{Rb}$ atoms in the presence of a longitudinal magnetic field experiences circular birefringence, which induces a relative phase shift between the $σ_+$ and $σ_-$ polarization components. This phase shift manifests itself as the angular rotation of a petal-shaped interference pattern, enabling the MOR angle to be determined directly from the spatial intensity distribution. Unlike conventional MOR detection techniques based on balanced polarimetry or Stokes-parameter reconstruction, the proposed method requires only a fixed-axis polarization projection and avoids computationally intensive polarization analysis. By translating polarization rotation into a topology-dependent spatial observable, the scheme enables direct and spatially resolved magnetic-field measurements. Furthermore, the use of electromagnetically induced transparency (EIT) allows low-loss operation while preserving high sensitivity. These characteristics make the proposed technique a promising platform for optical magnetometry and structured-light-based quantum sensing.

physics.atom-phCross-listedarXiv:2603.25781•Mar 27, 2026•0 citations

Spatial-Light-Modulator-Based Axial Energy- Shaping Optimization Method for Probe Light in SERF Atomic Magnetometers

Fangzhou Ling, Xiujie Fang, Kun CHEN +5 more

This paper proposes a wavefront-shaping approach for weak magnetic-field detection in spin-exchangerelaxation-free (SERF) atomic magnetometers. A spatial light modulator (SLM) is employed to tailor the axial energy distribution of the probe beam inside the vapor cell, aiming to enhance the effective sensitivity to ultra-weak magneto-optical rotation signals. In near-resonant SERF operation, the probe beam undergoes non-negligible absorption along propagation, while the atomic spin polarization typically exhibits a “low–highextensible route to improving thelow” longitudinal profile. Motivated by this mismatch, we programmatically design the incident wavefront so that the incell probe intensity follows a similar “low–high–low” axial distribution, thereby maximizing the path-integrated Faraday rotation under a fixed photon budget. Theoretical modeling and numerical simulations show that, compared with a uniformly incident Gaussian probe, the wavefront-shaped probe can increase the path-integrated rotation signal by up to ~30% without increasing optical power. To provide experimental evidence that spatial intensity engineering of the probe directly impacts the readout chain, we further perform a proof-of-concept transverse validation experiment by comparing Gaussian and flat-top probes generated using a beam-homogenizing waveplate. Under matched probe spot size, sensitivity spectra are measured at probe powers of 2, 4, 6, 8, and 10 mW. Across all tested powers, the flat-top probe consistently reduces the band-averaged sensitivity over 20–45 Hz by approximately 8%–17% relative to the Gaussian probe, indicating a lower effective noise floor and improved readout signal-to-noise ratio. These results support spatial beam shaping as a feasible and extensible route to improving the signal-to-noise ratio and effective sensitivity of SERF atomic magnetometers for ultra-weak magnetic-field measurements.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2026•0 citations

Ultra-sensitive single-beam atom-optical magnetometer using weak measurement method

Vineeth Francis Thalakottoor Jose Chacko, Rashmi Ranjan Suna, P. K. Madhu +2 more

Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb85 atoms, in response to change in longitudinal magnetic field (δBz) is demonstrated using the weak measurement method. The polarization rotation angle measurement sensitivity (δϕ) of 16 μrad and hence of the magnetometer of 1 nT, achieved using the weak measurement method is better than the balanced optical polarimetry results by a factor of three. The improvement in the measurement sensitivity is realized via optical amplification of the polarization rotation angle via spin-orbit coupled light beam-field. The method is devoid of external rf(/ac) modulation, allows for optimal tunability of sensitivity depending on the dynamic range of the applied magnetic field and the sensitivity can be further enhanced by operating in the spin exchange relaxation free regime of alkali spin polarization.

arXiv:1904.01663•AIP Advances•Jun 1, 2019•8 citations

Inverse weak measurement in a SERF magnetometer

Qian Cao, Liang Xu, Ziqian Yue +2 more

Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.

arXiv:2508.12306•Photonics Research•Oct 27, 2025•5 citations

Single-Beam Atomic Magnetometer Enhanced With Elliptically Polarized Reflected Light

An‐Ning Xu, Jin Peng, Yiran Yin +1 more

The ultra-sensitivity magnetometer plays an important role in fundamental physics and applications, including magnetoencephalography (MEG) and magnetocardiography (MCG). The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has great sensitivity but is limited by the relatively complicated dual-beam structure for application, leading to the development of the compact AM based on one single laser beam. Compared with the single-beam optically pumped magnetometer (OPM) detecting the absorption of the circularly polarized beam, the SERF AM based on an elliptically polarized single beam detecting the optical rotation angle of polarization has a better response, lower laser power, and no need for signal modulation or demodulation. Here, we would like to report an elliptically-polarized single-beam SERF AM enhanced by reflecting the probe beam, increasing the light-atom interaction. Moreover, unlike the previous reflecting AM using the beam splitter, we used a D-shape mirror to extract the reflected beam, avoiding power losses of both incident and reflected beam and destruction of polarization. The sensitivity of our device in the reflecting scheme reaches 5 fT/Hz1/2 at 9–60 Hz, satisfying the need to measure the human MEG/MCG or search for the fifth force. Our research paves the way for developing the compact SERF AM for multiple future applications.

IEEE Sensors Journal•Jun 27, 2024•7 citations

SERF-like magnetometry in room-temperature environment

Guzhi Bao, Jun Chen, Ruiqi Wang +2 more

We demonstrate an atomic magnetometry using amplitude-modulated pumping and hyperfine repumping techniques in a paraffin-coated cell. By exploiting the constructive interference between spins polarized by the pump beam and an additional repump beam, we observe a three-fold increase in the amplitude of magnetic resonance, along with a reduction in linewidth by approximately two times. The implementation of the repump beam effectively narrows the linewidth, demonstrating successful suppression of spin-exchange relaxation. This reduction in relaxation rate, combined with the enhanced signal, significantly improves the sensitivity of the magnetometer. Consequently, our technique offers a promising approach for achieving SERF-like magnetometry with sub-fT-level sensitivity in Earth-field range and room-temperature environment.

Optics Express•Sep 19, 2023•6 citations
This Letter presents what we believe to be a novel approach to enhance the sensitivity of spin-exchange-relaxation-free (SERF) atomic magnetometry by integrating a structured light combined with weak measurement. This strategy may address the limitations of detecting minute transverse magnetic fields due to low signal-to-noise ratios (SNR). We employ a Laguerre–Gaussian (LG) beam with tunable topological charge to amplify magneto-optical rotation (MOR) signals via weak measurement. We find that under a fixed magnetic field, the output polarization rotation angle monotonically increases as a function of the topological charges l . Furthermore, we experimentally demonstrate a 1.5 times signal enhancement using LG beams compared with Gaussian beams, achieving much better sensitivity. The results pave way for applications of structured light in ultra-sensitive atomic magnetometry.
A structured-light-based approach to magneto-optical rotation (MOR) magnetometry is proposed, in which magnetically induced polarization rotation is converted into a directly observable spatial displacement. A radially polarized Laguerre--Gaussian beam propagating through cold 87Rb^{87}\mathrm{Rb}87Rb atoms in the presence of a longitudinal magnetic field experiences circular birefringence, which induces a relative phase shift between the σ+σ_+σ+​ and σ−σ_-σ−​ polarization components. This phase shift manifests itself as the angular rotation of a petal-shaped interference pattern, enabling the MOR angle to be determined directly from the spatial intensity distribution. Unlike conventional MOR detection techniques based on balanced polarimetry or Stokes-parameter reconstruction, the proposed method requires only a fixed-axis polarization projection and avoids computationally intensive polarization analysis. By translating polarization rotation into a topology-dependent spatial observable, the scheme enables direct and spatially resolved magnetic-field measurements. Furthermore, the use of electromagnetically induced transparency (EIT) allows low-loss operation while preserving high sensitivity. These characteristics make the proposed technique a promising platform for optical magnetometry and structured-light-based quantum sensing.
This paper proposes a wavefront-shaping approach for weak magnetic-field detection in spin-exchangerelaxation-free (SERF) atomic magnetometers. A spatial light modulator (SLM) is employed to tailor the axial energy distribution of the probe beam inside the vapor cell, aiming to enhance the effective sensitivity to ultra-weak magneto-optical rotation signals. In near-resonant SERF operation, the probe beam undergoes non-negligible absorption along propagation, while the atomic spin polarization typically exhibits a “low–highextensible route to improving thelow” longitudinal profile. Motivated by this mismatch, we programmatically design the incident wavefront so that the incell probe intensity follows a similar “low–high–low” axial distribution, thereby maximizing the path-integrated Faraday rotation under a fixed photon budget. Theoretical modeling and numerical simulations show that, compared with a uniformly incident Gaussian probe, the wavefront-shaped probe can increase the path-integrated rotation signal by up to ~30% without increasing optical power. To provide experimental evidence that spatial intensity engineering of the probe directly impacts the readout chain, we further perform a proof-of-concept transverse validation experiment by comparing Gaussian and flat-top probes generated using a beam-homogenizing waveplate. Under matched probe spot size, sensitivity spectra are measured at probe powers of 2, 4, 6, 8, and 10 mW. Across all tested powers, the flat-top probe consistently reduces the band-averaged sensitivity over 20–45 Hz by approximately 8%–17% relative to the Gaussian probe, indicating a lower effective noise floor and improved readout signal-to-noise ratio. These results support spatial beam shaping as a feasible and extensible route to improving the signal-to-noise ratio and effective sensitivity of SERF atomic magnetometers for ultra-weak magnetic-field measurements.
Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb85 atoms, in response to change in longitudinal magnetic field (δBz) is demonstrated using the weak measurement method. The polarization rotation angle measurement sensitivity (δϕ) of 16 μrad and hence of the magnetometer of 1 nT, achieved using the weak measurement method is better than the balanced optical polarimetry results by a factor of three. The improvement in the measurement sensitivity is realized via optical amplification of the polarization rotation angle via spin-orbit coupled light beam-field. The method is devoid of external rf(/ac) modulation, allows for optimal tunability of sensitivity depending on the dynamic range of the applied magnetic field and the sensitivity can be further enhanced by operating in the spin exchange relaxation free regime of alkali spin polarization.
Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.
The ultra-sensitivity magnetometer plays an important role in fundamental physics and applications, including magnetoencephalography (MEG) and magnetocardiography (MCG). The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has great sensitivity but is limited by the relatively complicated dual-beam structure for application, leading to the development of the compact AM based on one single laser beam. Compared with the single-beam optically pumped magnetometer (OPM) detecting the absorption of the circularly polarized beam, the SERF AM based on an elliptically polarized single beam detecting the optical rotation angle of polarization has a better response, lower laser power, and no need for signal modulation or demodulation. Here, we would like to report an elliptically-polarized single-beam SERF AM enhanced by reflecting the probe beam, increasing the light-atom interaction. Moreover, unlike the previous reflecting AM using the beam splitter, we used a D-shape mirror to extract the reflected beam, avoiding power losses of both incident and reflected beam and destruction of polarization. The sensitivity of our device in the reflecting scheme reaches 5 fT/Hz1/2 at 9–60 Hz, satisfying the need to measure the human MEG/MCG or search for the fifth force. Our research paves the way for developing the compact SERF AM for multiple future applications.
We demonstrate an atomic magnetometry using amplitude-modulated pumping and hyperfine repumping techniques in a paraffin-coated cell. By exploiting the constructive interference between spins polarized by the pump beam and an additional repump beam, we observe a three-fold increase in the amplitude of magnetic resonance, along with a reduction in linewidth by approximately two times. The implementation of the repump beam effectively narrows the linewidth, demonstrating successful suppression of spin-exchange relaxation. This reduction in relaxation rate, combined with the enhanced signal, significantly improves the sensitivity of the magnetometer. Consequently, our technique offers a promising approach for achieving SERF-like magnetometry with sub-fT-level sensitivity in Earth-field range and room-temperature environment.