Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Performance optimization of a SERF atomic magnetometer based on flat-top light beam

Ziqi Yuan, Junjian Tang, Shudong 树东 Lin 林, Yueyang Zhai

Published Apr 18, 2024• 5 citations
Publisher

Abstract

We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spin-exchange relaxation-free (SERF) atomic magnetometers (AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped (FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.

DOI
10.1088/1674-1056/ad401b

Related papers

Impact of Three-Dimensional Beam-Splitting Light Fields on SERF Polarization and Light-Shift Noise

Jiayi Wei, Xiujie Fang, Xinxiu Zhou +5 more

This paper investigates the impact of pump-beam spatial shaping on spin-polarization uniformity and light-shiftrelated instability in spin-exchange relaxation-free (SERF) atomic magnetometers. Three representative pump profiles—a single Gaussian beam, a flat-top beam, and a split-beam configuration—are studied by combining a steady-state Bloch model with diffusion and a three-dimensional evaluation of the AC-Stark-shift-induced fictitious magnetic field. Simulations show that the Gaussian beam produces strong center-localized pumping with pronounced transverse/longitudinal gradients, whereas the flat-top beam improves transverse uniformity but decays faster along the propagation direction and tends to maintain a larger absolute light shift. By redistributing optical power into multiple beamlets and leveraging diffusion-driven smoothing, split-beam pumping yields a flatter polarization distribution, achieving the smallest depth-averaged polarization non-uniformity among the three cases, and mitigates the spatial inhomogeneity of$B_{\text{LS}}$by suppressing peak intensity. Experimental validation on a SERF platform is performed using an SLM-generated 2 × 2 beamlet array under identical total incident pump power. Frequency-response measurements at$z=0$and$z= \pm 5 ~\text{mm}$demonstrate improved longitudinal response uniformity, and noise-floor measurements in the$20-40 ~\text{Hz}$band exhibit a lower level with weaker$z$dependence, consistent with reduced light-shift-induced noise. The results indicate that split-beam pumping provides an effective and experimentally accessible route to balancing polarization uniformity and light-shift stability in SERF magnetometers.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2026•0 citations

A novel approach for enhancement of atomic spin polarization in spin-exchange relaxation-free gyroscopes based on a homogenized light field

Longyan Ma, Xiaohan Ge, Haoying Pang +7 more

Abstract Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.

Measurement Science and Technology•Nov 25, 2025•3 citations

A Performance-Enhanced Closed-Loop SERF Atomic Magnetometer

Ziao Liu, Jianli Li, Xiaoyu Li +3 more

The spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultrahigh sensitivity in ultraweak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF AM, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz$^{{1}/{2}}$in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.

IEEE Sensors Journal•Oct 1, 2024•5 citations

Spatial-Light-Modulator-Based Axial Energy- Shaping Optimization Method for Probe Light in SERF Atomic Magnetometers

Fangzhou Ling, Xiujie Fang, Kun CHEN +5 more

This paper proposes a wavefront-shaping approach for weak magnetic-field detection in spin-exchangerelaxation-free (SERF) atomic magnetometers. A spatial light modulator (SLM) is employed to tailor the axial energy distribution of the probe beam inside the vapor cell, aiming to enhance the effective sensitivity to ultra-weak magneto-optical rotation signals. In near-resonant SERF operation, the probe beam undergoes non-negligible absorption along propagation, while the atomic spin polarization typically exhibits a “low–highextensible route to improving thelow” longitudinal profile. Motivated by this mismatch, we programmatically design the incident wavefront so that the incell probe intensity follows a similar “low–high–low” axial distribution, thereby maximizing the path-integrated Faraday rotation under a fixed photon budget. Theoretical modeling and numerical simulations show that, compared with a uniformly incident Gaussian probe, the wavefront-shaped probe can increase the path-integrated rotation signal by up to ~30% without increasing optical power. To provide experimental evidence that spatial intensity engineering of the probe directly impacts the readout chain, we further perform a proof-of-concept transverse validation experiment by comparing Gaussian and flat-top probes generated using a beam-homogenizing waveplate. Under matched probe spot size, sensitivity spectra are measured at probe powers of 2, 4, 6, 8, and 10 mW. Across all tested powers, the flat-top probe consistently reduces the band-averaged sensitivity over 20–45 Hz by approximately 8%–17% relative to the Gaussian probe, indicating a lower effective noise floor and improved readout signal-to-noise ratio. These results support spatial beam shaping as a feasible and extensible route to improving the signal-to-noise ratio and effective sensitivity of SERF atomic magnetometers for ultra-weak magnetic-field measurements.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2026•0 citations

Static bias magnetic field assisted optical modulation triaxial SERF atomic magnetometer

Xiaoyu Li, Bangcheng Han, Shushan Gao +4 more

Abstract High-sensitivity triaxial magnetic field measurements are crucial in various scientific and industrial applications, with spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) standing out for their exceptional sensitivity. However, conventional methods for achieving triaxial measurements in SERF magnetometers typically involve multiple modulated magnetic fields, which introduce crosstalk challenges in array-based configurations. We propose a static bias magnetic field assisted optical modulation triaxial AM to address this limitation. In this configuration, the detuned circularly polarized light is utilized to achieve synchronous modulation of the fictitious magnetic field and pumping rate while incorporating a static bias magnetic field to generate a transverse projection component. We develop a comprehensive triaxial response model that fully considers the effects of the longitudinal spin polarization deflection. Building upon this model, we derive the relationship between the transverse spin component and the triaxial magnetic field and introduce parameter optimization methods to obtain optimal parameters, thus enabling triaxial measurements of 12 fT Hz −1/2 , 10 fT Hz −1/2 , and 15 fT Hz −1/2 along the x-, y -, and z -axes. Our approach offers significant advantages over existing methods, particularly in minimizing crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Moreover, the effective detection of simulated magnetocardiography signals highlights the practical applicability and reliability of the proposed method in real-world scenarios.

Measurement Science and Technology•Nov 7, 2025•2 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•74 citations
We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spin-exchange relaxation-free (SERF) atomic magnetometers (AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped (FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.
This paper investigates the impact of pump-beam spatial shaping on spin-polarization uniformity and light-shiftrelated instability in spin-exchange relaxation-free (SERF) atomic magnetometers. Three representative pump profiles—a single Gaussian beam, a flat-top beam, and a split-beam configuration—are studied by combining a steady-state Bloch model with diffusion and a three-dimensional evaluation of the AC-Stark-shift-induced fictitious magnetic field. Simulations show that the Gaussian beam produces strong center-localized pumping with pronounced transverse/longitudinal gradients, whereas the flat-top beam improves transverse uniformity but decays faster along the propagation direction and tends to maintain a larger absolute light shift. By redistributing optical power into multiple beamlets and leveraging diffusion-driven smoothing, split-beam pumping yields a flatter polarization distribution, achieving the smallest depth-averaged polarization non-uniformity among the three cases, and mitigates the spatial inhomogeneity ofBLSB_{\text{LS}}BLS​by suppressing peak intensity. Experimental validation on a SERF platform is performed using an SLM-generated 2 × 2 beamlet array under identical total incident pump power. Frequency-response measurements atz=0z=0z=0andz=±5 mmz= \pm 5 ~\text{mm}z=±5 mmdemonstrate improved longitudinal response uniformity, and noise-floor measurements in the20−40 Hz20-40 ~\text{Hz}20−40 Hzband exhibit a lower level with weakerzzzdependence, consistent with reduced light-shift-induced noise. The results indicate that split-beam pumping provides an effective and experimentally accessible route to balancing polarization uniformity and light-shift stability in SERF magnetometers.
Abstract Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.
The spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultrahigh sensitivity in ultraweak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF AM, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz1/2^{{1}/{2}}1/2in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.
This paper proposes a wavefront-shaping approach for weak magnetic-field detection in spin-exchangerelaxation-free (SERF) atomic magnetometers. A spatial light modulator (SLM) is employed to tailor the axial energy distribution of the probe beam inside the vapor cell, aiming to enhance the effective sensitivity to ultra-weak magneto-optical rotation signals. In near-resonant SERF operation, the probe beam undergoes non-negligible absorption along propagation, while the atomic spin polarization typically exhibits a “low–highextensible route to improving thelow” longitudinal profile. Motivated by this mismatch, we programmatically design the incident wavefront so that the incell probe intensity follows a similar “low–high–low” axial distribution, thereby maximizing the path-integrated Faraday rotation under a fixed photon budget. Theoretical modeling and numerical simulations show that, compared with a uniformly incident Gaussian probe, the wavefront-shaped probe can increase the path-integrated rotation signal by up to ~30% without increasing optical power. To provide experimental evidence that spatial intensity engineering of the probe directly impacts the readout chain, we further perform a proof-of-concept transverse validation experiment by comparing Gaussian and flat-top probes generated using a beam-homogenizing waveplate. Under matched probe spot size, sensitivity spectra are measured at probe powers of 2, 4, 6, 8, and 10 mW. Across all tested powers, the flat-top probe consistently reduces the band-averaged sensitivity over 20–45 Hz by approximately 8%–17% relative to the Gaussian probe, indicating a lower effective noise floor and improved readout signal-to-noise ratio. These results support spatial beam shaping as a feasible and extensible route to improving the signal-to-noise ratio and effective sensitivity of SERF atomic magnetometers for ultra-weak magnetic-field measurements.
Abstract High-sensitivity triaxial magnetic field measurements are crucial in various scientific and industrial applications, with spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) standing out for their exceptional sensitivity. However, conventional methods for achieving triaxial measurements in SERF magnetometers typically involve multiple modulated magnetic fields, which introduce crosstalk challenges in array-based configurations. We propose a static bias magnetic field assisted optical modulation triaxial AM to address this limitation. In this configuration, the detuned circularly polarized light is utilized to achieve synchronous modulation of the fictitious magnetic field and pumping rate while incorporating a static bias magnetic field to generate a transverse projection component. We develop a comprehensive triaxial response model that fully considers the effects of the longitudinal spin polarization deflection. Building upon this model, we derive the relationship between the transverse spin component and the triaxial magnetic field and introduce parameter optimization methods to obtain optimal parameters, thus enabling triaxial measurements of 12 fT Hz −1/2 , 10 fT Hz −1/2 , and 15 fT Hz −1/2 along the x-, y -, and z -axes. Our approach offers significant advantages over existing methods, particularly in minimizing crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Moreover, the effective detection of simulated magnetocardiography signals highlights the practical applicability and reliability of the proposed method in real-world scenarios.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.