IEEE International Instrumentation and Measurement Technology Conference

Impact of Three-Dimensional Beam-Splitting Light Fields on SERF Polarization and Light-Shift Noise

Jiayi Wei, Xiujie Fang, Xinxiu Zhou, Xin Xu, Kun CHEN, Yueshen Wang, Yanan Gao, Danyue Ma

Published May 1, 2026• 0 citations
Publisher

Abstract

This paper investigates the impact of pump-beam spatial shaping on spin-polarization uniformity and light-shiftrelated instability in spin-exchange relaxation-free (SERF) atomic magnetometers. Three representative pump profiles—a single Gaussian beam, a flat-top beam, and a split-beam configuration—are studied by combining a steady-state Bloch model with diffusion and a three-dimensional evaluation of the AC-Stark-shift-induced fictitious magnetic field. Simulations show that the Gaussian beam produces strong center-localized pumping with pronounced transverse/longitudinal gradients, whereas the flat-top beam improves transverse uniformity but decays faster along the propagation direction and tends to maintain a larger absolute light shift. By redistributing optical power into multiple beamlets and leveraging diffusion-driven smoothing, split-beam pumping yields a flatter polarization distribution, achieving the smallest depth-averaged polarization non-uniformity among the three cases, and mitigates the spatial inhomogeneity of$B_{\text{LS}}$by suppressing peak intensity. Experimental validation on a SERF platform is performed using an SLM-generated 2 × 2 beamlet array under identical total incident pump power. Frequency-response measurements at$z=0$and$z= \pm 5 ~\text{mm}$demonstrate improved longitudinal response uniformity, and noise-floor measurements in the$20-40 ~\text{Hz}$band exhibit a lower level with weaker$z$dependence, consistent with reduced light-shift-induced noise. The results indicate that split-beam pumping provides an effective and experimentally accessible route to balancing polarization uniformity and light-shift stability in SERF magnetometers.

DOI
10.1109/i2mtc66907.2026.11694990

Related papers

Spatial-Light-Modulator-Based Axial Energy- Shaping Optimization Method for Probe Light in SERF Atomic Magnetometers

Fangzhou Ling, Xiujie Fang, Kun CHEN +5 more

This paper proposes a wavefront-shaping approach for weak magnetic-field detection in spin-exchangerelaxation-free (SERF) atomic magnetometers. A spatial light modulator (SLM) is employed to tailor the axial energy distribution of the probe beam inside the vapor cell, aiming to enhance the effective sensitivity to ultra-weak magneto-optical rotation signals. In near-resonant SERF operation, the probe beam undergoes non-negligible absorption along propagation, while the atomic spin polarization typically exhibits a “low–highextensible route to improving thelow” longitudinal profile. Motivated by this mismatch, we programmatically design the incident wavefront so that the incell probe intensity follows a similar “low–high–low” axial distribution, thereby maximizing the path-integrated Faraday rotation under a fixed photon budget. Theoretical modeling and numerical simulations show that, compared with a uniformly incident Gaussian probe, the wavefront-shaped probe can increase the path-integrated rotation signal by up to ~30% without increasing optical power. To provide experimental evidence that spatial intensity engineering of the probe directly impacts the readout chain, we further perform a proof-of-concept transverse validation experiment by comparing Gaussian and flat-top probes generated using a beam-homogenizing waveplate. Under matched probe spot size, sensitivity spectra are measured at probe powers of 2, 4, 6, 8, and 10 mW. Across all tested powers, the flat-top probe consistently reduces the band-averaged sensitivity over 20–45 Hz by approximately 8%–17% relative to the Gaussian probe, indicating a lower effective noise floor and improved readout signal-to-noise ratio. These results support spatial beam shaping as a feasible and extensible route to improving the signal-to-noise ratio and effective sensitivity of SERF atomic magnetometers for ultra-weak magnetic-field measurements.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2026•0 citations

Performance optimization of a SERF atomic magnetometer based on flat-top light beam

Ziqi Yuan, Junjian Tang, Shudong 树东 Lin 林 +1 more

We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spin-exchange relaxation-free (SERF) atomic magnetometers (AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped (FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.

Chinese Physics B•Apr 18, 2024•5 citations

Suppressing Spatial Inhomogeneity in Spin Polarization and Light Shift in Atomic Magnetometer Array Using Frequency-Paired Counter-Propagating Pumps

Jin Peng, An‐Ning Xu, Yuanjiang Tang +5 more

In spin-exchange-relaxation-free (SERF) atomic magnetometers (AMs), the attenuation of circularly polarized pump beam introduces spatial-dependent artificial magnetic fields in atomic spin polarization and light shift. In general, such a spatial-dependent effective magnetic field, especially prevalent in single-cell magnetometer arrays, cannot be uniformly compensated over the entire excitation region, resulting in a complex distributed compensation mask effect. In addition, any external effective-field-compensation methods inevitably complicate the final analysis of the unknown magnetic field measured. Here, we report a new excitation scheme that can substantially suppress spatial nonuniformity due to pump beam attenuation. Using counter-propagating pump beams with symmetrically red- and blue-detuning-paired frequencies, we demonstrate a significant reduction of spatial inhomogeneity in atomic spin polarization and light shift in comparison with the usual single-frequency unidirection and counter-propagating pump schemes. Employing this red-/blue-detuning-paired pump scheme, we construct a single-cell, four-channel SERF magnetometer array with high spatial homogeneity. We demonstrate ~10-fT/Hz$^{{1}/{2}}$sensitivity in the 5–45-Hz band for all four channels, with a gradient sensitivity of 2 fT/Hz1/2$^{{1}/{2}}$/cm in the same band. This new scheme enables the development of single-vapor-cell, high-uniformity multichannel magnetic field mapping devices with potential applications in magnetoencephalography (MEG) and magnetocardiography (MCG), or in searching for exotic spin-dependent interactions.

IEEE Sensors Journal•Aug 20, 2024•6 citations

A novel approach for enhancement of atomic spin polarization in spin-exchange relaxation-free gyroscopes based on a homogenized light field

Longyan Ma, Xiaohan Ge, Haoying Pang +7 more

Abstract Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.

Measurement Science and Technology•Nov 25, 2025•3 citations

Improvement of polarization uniformity in spin-exchange relaxation-free comagnetometer based on pump beam reflection compensation

JiaLu Meng, Feng Liu, Xihui Dou +2 more

Spin exchange relaxation free (SERF) comagnetometers, which use coupled alkali metal and noble gas spins, are promising for precision measurements due to their potential for miniaturization and high sensitivity. In these systems, alkali atoms are optically pumped with circularly polarized light, and their polarization is transferred to noble gas nuclei via spin-exchange collisions. However, spatial inhomogeneities in alkali polarization induced by factors such as optical absorption, gas diffusion, and temperature gradients generate effective magnetic field gradients for the noble gas spins. These gradients accelerate spin relaxation and degrade overall sensor performance. This work introduces a pump beam reflection compensation scheme to improve alkali polarization uniformity in a SERF comagnetometer. By retro reflecting the pump beam back along its original optical path with reversed helicity, alkali atoms are repolarized from the opposite direction. This counter propagating beam compensates polarization gradients through reverse optical pumping, thereby homogenizing the effective field experienced by the noble gas spins. The modified pumping configuration enhances spatial uniformity while maintaining a simple and compact sensor architecture. A revised polarization rate model incorporating the retro reflected beam is presented. Simulations comparing single beam, 90% reflection, and total reflection configurations confirm a marked reduction in alkali polarization gradients for reflection based designs. Experimentally, the transverse relaxation time of the noble gas spins is extended by 77.66%, indicating significantly suppressed gradient induced decoherence. The proposed method supports the development of miniaturized, high performance SERF comagnetometers.

Sixth Symposium on Novel Optoelectronic Detection Technology and Applications•May 11, 2026•0 citations

In situ decoupling of pump-induced spin polarization noise in atomic spin sensors

Dinghui Gong, Xiaofei Huang, Di Gong +5 more

In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.

Applied Physics Letters•Aug 24, 2026•0 citations
This paper investigates the impact of pump-beam spatial shaping on spin-polarization uniformity and light-shiftrelated instability in spin-exchange relaxation-free (SERF) atomic magnetometers. Three representative pump profiles—a single Gaussian beam, a flat-top beam, and a split-beam configuration—are studied by combining a steady-state Bloch model with diffusion and a three-dimensional evaluation of the AC-Stark-shift-induced fictitious magnetic field. Simulations show that the Gaussian beam produces strong center-localized pumping with pronounced transverse/longitudinal gradients, whereas the flat-top beam improves transverse uniformity but decays faster along the propagation direction and tends to maintain a larger absolute light shift. By redistributing optical power into multiple beamlets and leveraging diffusion-driven smoothing, split-beam pumping yields a flatter polarization distribution, achieving the smallest depth-averaged polarization non-uniformity among the three cases, and mitigates the spatial inhomogeneity ofBLSB_{\text{LS}}BLS​by suppressing peak intensity. Experimental validation on a SERF platform is performed using an SLM-generated 2 × 2 beamlet array under identical total incident pump power. Frequency-response measurements atz=0z=0z=0andz=±5 mmz= \pm 5 ~\text{mm}z=±5 mmdemonstrate improved longitudinal response uniformity, and noise-floor measurements in the20−40 Hz20-40 ~\text{Hz}20−40 Hzband exhibit a lower level with weakerzzzdependence, consistent with reduced light-shift-induced noise. The results indicate that split-beam pumping provides an effective and experimentally accessible route to balancing polarization uniformity and light-shift stability in SERF magnetometers.
This paper proposes a wavefront-shaping approach for weak magnetic-field detection in spin-exchangerelaxation-free (SERF) atomic magnetometers. A spatial light modulator (SLM) is employed to tailor the axial energy distribution of the probe beam inside the vapor cell, aiming to enhance the effective sensitivity to ultra-weak magneto-optical rotation signals. In near-resonant SERF operation, the probe beam undergoes non-negligible absorption along propagation, while the atomic spin polarization typically exhibits a “low–highextensible route to improving thelow” longitudinal profile. Motivated by this mismatch, we programmatically design the incident wavefront so that the incell probe intensity follows a similar “low–high–low” axial distribution, thereby maximizing the path-integrated Faraday rotation under a fixed photon budget. Theoretical modeling and numerical simulations show that, compared with a uniformly incident Gaussian probe, the wavefront-shaped probe can increase the path-integrated rotation signal by up to ~30% without increasing optical power. To provide experimental evidence that spatial intensity engineering of the probe directly impacts the readout chain, we further perform a proof-of-concept transverse validation experiment by comparing Gaussian and flat-top probes generated using a beam-homogenizing waveplate. Under matched probe spot size, sensitivity spectra are measured at probe powers of 2, 4, 6, 8, and 10 mW. Across all tested powers, the flat-top probe consistently reduces the band-averaged sensitivity over 20–45 Hz by approximately 8%–17% relative to the Gaussian probe, indicating a lower effective noise floor and improved readout signal-to-noise ratio. These results support spatial beam shaping as a feasible and extensible route to improving the signal-to-noise ratio and effective sensitivity of SERF atomic magnetometers for ultra-weak magnetic-field measurements.
We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spin-exchange relaxation-free (SERF) atomic magnetometers (AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped (FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.
In spin-exchange-relaxation-free (SERF) atomic magnetometers (AMs), the attenuation of circularly polarized pump beam introduces spatial-dependent artificial magnetic fields in atomic spin polarization and light shift. In general, such a spatial-dependent effective magnetic field, especially prevalent in single-cell magnetometer arrays, cannot be uniformly compensated over the entire excitation region, resulting in a complex distributed compensation mask effect. In addition, any external effective-field-compensation methods inevitably complicate the final analysis of the unknown magnetic field measured. Here, we report a new excitation scheme that can substantially suppress spatial nonuniformity due to pump beam attenuation. Using counter-propagating pump beams with symmetrically red- and blue-detuning-paired frequencies, we demonstrate a significant reduction of spatial inhomogeneity in atomic spin polarization and light shift in comparison with the usual single-frequency unidirection and counter-propagating pump schemes. Employing this red-/blue-detuning-paired pump scheme, we construct a single-cell, four-channel SERF magnetometer array with high spatial homogeneity. We demonstrate ~10-fT/Hz1/2^{{1}/{2}}1/2sensitivity in the 5–45-Hz band for all four channels, with a gradient sensitivity of 2 fT/Hz1/21/2^{{1}/{2}}1/2/cm in the same band. This new scheme enables the development of single-vapor-cell, high-uniformity multichannel magnetic field mapping devices with potential applications in magnetoencephalography (MEG) and magnetocardiography (MCG), or in searching for exotic spin-dependent interactions.
Abstract Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.
Spin exchange relaxation free (SERF) comagnetometers, which use coupled alkali metal and noble gas spins, are promising for precision measurements due to their potential for miniaturization and high sensitivity. In these systems, alkali atoms are optically pumped with circularly polarized light, and their polarization is transferred to noble gas nuclei via spin-exchange collisions. However, spatial inhomogeneities in alkali polarization induced by factors such as optical absorption, gas diffusion, and temperature gradients generate effective magnetic field gradients for the noble gas spins. These gradients accelerate spin relaxation and degrade overall sensor performance. This work introduces a pump beam reflection compensation scheme to improve alkali polarization uniformity in a SERF comagnetometer. By retro reflecting the pump beam back along its original optical path with reversed helicity, alkali atoms are repolarized from the opposite direction. This counter propagating beam compensates polarization gradients through reverse optical pumping, thereby homogenizing the effective field experienced by the noble gas spins. The modified pumping configuration enhances spatial uniformity while maintaining a simple and compact sensor architecture. A revised polarization rate model incorporating the retro reflected beam is presented. Simulations comparing single beam, 90% reflection, and total reflection configurations confirm a marked reduction in alkali polarization gradients for reflection based designs. Experimentally, the transverse relaxation time of the noble gas spins is extended by 77.66%, indicating significantly suppressed gradient induced decoherence. The proposed method supports the development of miniaturized, high performance SERF comagnetometers.
In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.