Saturated absorption spectroscopy of the near-UV Cs atom 6S1/2-7P1/2 transition in a MEMS vapor cell

Emmanuel Klinger, C. M. Rivera-Aguilar, Rémy Vicarini, Nicolas Passilly, Rodolphe Boudot

Published Jun 25, 2024• 0 citations
OpenAlex

Abstract

Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices, such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping. It has offered in its industrial and commercialized version an ultra-low size-power-instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s.Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 − 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fullyminiaturized and low-power optical clock.In this work, we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 – 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance. Latest results will be presented at the conference.

Related papers

Saturated absorption spectroscopy of the Cs atom 6S1/2 → 7P1/2 transition at 459 nm in a microfabricated vapor cell

Emmanuel Klinger, Andrei Mursa, C. M. Rivera-Aguilar +3 more

Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.

•Sep 30, 2024•0 citations

Sub-Doppler spectroscopy of the Cs atom 6S1/2–7P1/2 transition at 459 nm in a microfabricated vapor cell

Emmanuel Klinger, Andrei Mursa, C. M. Rivera-Aguilar +3 more

We report on the characterization of sub-Doppler resonances detected by probing the 6S1/2 - 7P1/2 transition of the Cs atom at 459 nm in a microfabricated vapor cell. The dependence of the sub-Doppler resonance (linewidth, amplitude) on some key experimental parameters, including the laser intensity and the cell temperature, is investigated. These narrow atomic resonances are of interest for high-resolution spectroscopy and instrumentation and may constitute the basis of a high-stability microcell optical standard.

arXiv:2311.18459•Optics Letters•Mar 5, 2024•18 citations

Investigations for a Miniature Optical Frequency Reference Based on High-Contrast Sub-Doppler Resonance in a MEMS Cesium Vapor Cell

Denis V. Brazhnikov, Michael Petersen, Grégoire Coget +4 more

Many of modern quantum technologies require the development of high-performance and low-power consumption miniaturized devices such as laser systems, atomic clocks, magnetometers and other quantum sensors. These instruments are to date often based on the use of chip-size diode lasers and microfabricated (MEMS) cells filled with alkali atoms [1]. An interesting challenge concerns the development of miniaturized optical frequency references (OFR). Different approaches have been engaged in this direction. One of the most successful example is a rubidium microcell-based OFR, involving the two-photon spectroscopy technique. This approach has recently demonstrated a remarkable frequency stability level of 4.4×10–12 at 1 s [2]. The present study is focused on a simple alternative approach based on sub-Doppler spectroscopy (SDS) with counter-propagating light beams. We propose to use dual-frequency light beams with orthogonal linear polarizations and frequency difference w1–w2 = Dhfs, with Dhfs the frequency of the atom ground-state hyper-fine splitting. First dual-frequency sub-Doppler spectroscopy (DF SDS) experiments have been performed with cmscale cells [3,4]. In the present study, we present preliminary spectroscopy and frequency stability results of alaser stabilized using DF SDS with a Cs vapor microfabricated cell [5] (Fig.1a). An extended-cavity diode laser (ECDL) source and a Mach-Zehnder intensity EOM are used to obtain the dual-frequency light field. A forward beam goes through the cell and is then reflected by a mirror to create the backward beam.

•Apr 8, 2019•0 citations

Microfabricated vapor cell atomic clocks at FEMTO-ST

Clément Carlé, Martin Callejo, Andrei Mursa +8 more

The convergence of atomic spectroscopy, MEMS cell technologies and integrated photonics has led to the deployment of high-precision chip-scale atomic devices [1]. In this talk, we will present in-progress studies at FEMTO-ST Institute, France, for the development of microcellbased microwave and optical atomic clocks, with enhanced stability performances. In the first part, we will talk about the demonstration of CPT-based microwave cell clocks with stability at 1 day in the low 10−12 range [2], made possible thanks to the combination of advanced Ramsey-based interrogation sequences [3] and cells built with low gas permeation windows [4-5]. In the second part, we will discuss the in-progress development of a microcell-based optical frequency reference based on the two-photon transition of Rb atom at 778 nm. An encouraging short-term stability of 3 × 10−13 at 1 s and 3 × 10−14 at 100 s has been recently achieved [6]. Future studies will be briefly discussed.

•Sep 30, 2024•1 citation

Short-term stability of Cs microcell-stabilized lasers using dual-frequency sub-Doppler spectroscopy

Anthony Gusching, M. Petersen, Nicolas Passilly +3 more

The combination of atomic spectroscopy, integrated photonics, and microelectromechanical systems leads the way to the demonstration of microcell-based optical atomic clocks. Here, we report the short-term stability budget of table-top Cs microcell-stabilized lasers based on dual-frequency sub-Doppler spectroscopy (DFSDS). The dependence of the sub-Doppler resonance properties on key experimental parameters is studied. The detection noise budget and absolute phase noise measurements are in good agreement with the measured short-term frequency stability of the laser beatnote, at the level of 1.1 × 10 − 12 τ − 1 / 2 until 100 s, currently limited by the intermodulation effect from a distributed-feedback laser setup. The fractional frequency stability of the laser beatnote at 1 s is about 100 times greater than that of commercial microwave chip-scale atomic clocks and validates interest in the DFSDS approach for the development of high-performance microcell-based optical standards.

Journal of the Optical Society of America B•Sep 20, 2021•33 citations

Compact optical frequency standard using a wafer-level MEMS vapor cell

Qiaohui Yang, Zhenyu Hu, Tian Liu +6 more

Atomic clocks represent the most advanced instruments for providing time-frequency standards, with increasing demand for designs that offer high frequency stability while minimizing size. Central to an atomic clock’s function is the atomic vapor cell, which serves as the quantum reference. Compared to traditional cells, wafer-level micro-electro-mechanical systems (MEMS) vapor cells enable cost-effective, scalable production and facilitate integration with silicon-based chips. In this work, we present a wafer-level MEMS vapor cell featuring an innovative silicon-glass-silicon transverse optical path structure. A single wafer is used to fabricate 24 identical atomic vapor cells, each with precise dimensions of 14 mm×14 mm×4.3 mm, ensuring scalability. We demonstrate an optical frequency standard that combines modulation transfer spectroscopy (MTS) with a MEMS vapor cell, featuring a compact design with excellent performance. This frequency standard achieves stability over averaging times of 1–400 s, with short-term stability of 2.6×10 −13 at 1 s and 5.1×10 −14 at 200 s. The laser linewidth is only 3.9 kHz, marking a substantial improvement over existing thermal standards, and opening potential applications in navigation, radar, and precision measurement. This work provides a crucial step toward the development of chip-scale optical clocks.

Photonics Research•Jun 12, 2025•10 citations
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices, such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping. It has offered in its industrial and commercialized version an ultra-low size-power-instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s.Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 − 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fullyminiaturized and low-power optical clock.In this work, we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 – 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance. Latest results will be presented at the conference.
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.
We report on the characterization of sub-Doppler resonances detected by probing the 6S1/2 - 7P1/2 transition of the Cs atom at 459 nm in a microfabricated vapor cell. The dependence of the sub-Doppler resonance (linewidth, amplitude) on some key experimental parameters, including the laser intensity and the cell temperature, is investigated. These narrow atomic resonances are of interest for high-resolution spectroscopy and instrumentation and may constitute the basis of a high-stability microcell optical standard.
Many of modern quantum technologies require the development of high-performance and low-power consumption miniaturized devices such as laser systems, atomic clocks, magnetometers and other quantum sensors. These instruments are to date often based on the use of chip-size diode lasers and microfabricated (MEMS) cells filled with alkali atoms [1]. An interesting challenge concerns the development of miniaturized optical frequency references (OFR). Different approaches have been engaged in this direction. One of the most successful example is a rubidium microcell-based OFR, involving the two-photon spectroscopy technique. This approach has recently demonstrated a remarkable frequency stability level of 4.4×10–12 at 1 s [2]. The present study is focused on a simple alternative approach based on sub-Doppler spectroscopy (SDS) with counter-propagating light beams. We propose to use dual-frequency light beams with orthogonal linear polarizations and frequency difference w1–w2 = Dhfs, with Dhfs the frequency of the atom ground-state hyper-fine splitting. First dual-frequency sub-Doppler spectroscopy (DF SDS) experiments have been performed with cmscale cells [3,4]. In the present study, we present preliminary spectroscopy and frequency stability results of alaser stabilized using DF SDS with a Cs vapor microfabricated cell [5] (Fig.1a). An extended-cavity diode laser (ECDL) source and a Mach-Zehnder intensity EOM are used to obtain the dual-frequency light field. A forward beam goes through the cell and is then reflected by a mirror to create the backward beam.
The convergence of atomic spectroscopy, MEMS cell technologies and integrated photonics has led to the deployment of high-precision chip-scale atomic devices [1]. In this talk, we will present in-progress studies at FEMTO-ST Institute, France, for the development of microcellbased microwave and optical atomic clocks, with enhanced stability performances. In the first part, we will talk about the demonstration of CPT-based microwave cell clocks with stability at 1 day in the low 10−12 range [2], made possible thanks to the combination of advanced Ramsey-based interrogation sequences [3] and cells built with low gas permeation windows [4-5]. In the second part, we will discuss the in-progress development of a microcell-based optical frequency reference based on the two-photon transition of Rb atom at 778 nm. An encouraging short-term stability of 3 × 10−13 at 1 s and 3 × 10−14 at 100 s has been recently achieved [6]. Future studies will be briefly discussed.
The combination of atomic spectroscopy, integrated photonics, and microelectromechanical systems leads the way to the demonstration of microcell-based optical atomic clocks. Here, we report the short-term stability budget of table-top Cs microcell-stabilized lasers based on dual-frequency sub-Doppler spectroscopy (DFSDS). The dependence of the sub-Doppler resonance properties on key experimental parameters is studied. The detection noise budget and absolute phase noise measurements are in good agreement with the measured short-term frequency stability of the laser beatnote, at the level of 1.1 × 10 − 12 τ − 1 / 2 until 100 s, currently limited by the intermodulation effect from a distributed-feedback laser setup. The fractional frequency stability of the laser beatnote at 1 s is about 100 times greater than that of commercial microwave chip-scale atomic clocks and validates interest in the DFSDS approach for the development of high-performance microcell-based optical standards.
Atomic clocks represent the most advanced instruments for providing time-frequency standards, with increasing demand for designs that offer high frequency stability while minimizing size. Central to an atomic clock’s function is the atomic vapor cell, which serves as the quantum reference. Compared to traditional cells, wafer-level micro-electro-mechanical systems (MEMS) vapor cells enable cost-effective, scalable production and facilitate integration with silicon-based chips. In this work, we present a wafer-level MEMS vapor cell featuring an innovative silicon-glass-silicon transverse optical path structure. A single wafer is used to fabricate 24 identical atomic vapor cells, each with precise dimensions of 14 mm×14 mm×4.3 mm, ensuring scalability. We demonstrate an optical frequency standard that combines modulation transfer spectroscopy (MTS) with a MEMS vapor cell, featuring a compact design with excellent performance. This frequency standard achieves stability over averaging times of 1–400 s, with short-term stability of 2.6×10 −13 at 1 s and 5.1×10 −14 at 200 s. The laser linewidth is only 3.9 kHz, marking a substantial improvement over existing thermal standards, and opening potential applications in navigation, radar, and precision measurement. This work provides a crucial step toward the development of chip-scale optical clocks.