Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Microfabricated vapor cell atomic clocks at FEMTO-ST

Clément Carlé, Martin Callejo, Andrei Mursa, Moustafa Abdel Hafiz, Quentin A. A. Tanguy, Rémy Vicarini, Jacques Millo, Vincent N. Maurice, Emmanuel Klinger, Nicolas Passilly, Rodolphe Boudot

Published Sep 30, 2024• 1 citation
OpenAlex

Abstract

The convergence of atomic spectroscopy, MEMS cell technologies and integrated photonics has led to the deployment of high-precision chip-scale atomic devices [1]. In this talk, we will present in-progress studies at FEMTO-ST Institute, France, for the development of microcellbased microwave and optical atomic clocks, with enhanced stability performances. In the first part, we will talk about the demonstration of CPT-based microwave cell clocks with stability at 1 day in the low 10−12 range [2], made possible thanks to the combination of advanced Ramsey-based interrogation sequences [3] and cells built with low gas permeation windows [4-5]. In the second part, we will discuss the in-progress development of a microcell-based optical frequency reference based on the two-photon transition of Rb atom at 778 nm. An encouraging short-term stability of 3 × 10−13 at 1 s and 3 × 10−14 at 100 s has been recently achieved [6]. Future studies will be briefly discussed.

Related papers

Short-term stability of a microcell optical reference based on the Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

arXiv:2407.00841•Journal of the Optical Society of America B•Nov 22, 2024•15 citations

Saturated absorption spectroscopy of the Cs atom 6S1/2 → 7P1/2 transition at 459 nm in a microfabricated vapor cell

Emmanuel Klinger, Andrei Mursa, C. M. Rivera-Aguilar +3 more

Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.

•Sep 30, 2024•0 citations

Pulsed-CPT Cs-Ne microcell atomic clock with frequency stability below 2 × 10 −12 at 10 5 s

Clément Carlé, Moustafa Abdel Hafiz, Shervin Keshavarzi +3 more

We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.

Optics Express•Feb 10, 2023•31 citations

μ POP Clock: A Microcell Atomic Clock Based on a Double-Resonance Ramsey Scheme

Etienne Batori, C. Affolderbach, Matthieu Pellaton +5 more

We demonstrate and study a microcell microwave atomic clock based on optical-microwave double resonance (DR) interrogation operated in a pulsed Ramsey scheme, called the \ensuremath{\mu}POP clock, based on a microfabricated Rb vapor cell and a micro-loop-gap microwave resonator. For the mm-scale dimensions of this cell, the population and coherence relaxation rates of the Rb clock transition are on the order of 4--5 kHz, which puts constraints on the useful Ramsey times and overall pulse sequence in view of optimized clock performance. Our proof-of-principle demonstration of the \ensuremath{\mu}POP clock shows that the pulsed DR approach is nevertheless feasible and results in a short-term clock stability of 1 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}11}$ \ensuremath{\tau}${}^{\ensuremath{-}1/2}$ and reaching the \ensuremath{\le}2 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ level at timescales of 1000 s to one day. The short-term instability budget established for the \ensuremath{\mu}POP clock shows that the main limitation to the short-term stability arises from the detection noise. Thanks to the pulsed Ramsey scheme, light-shift effects are strongly reduced in the \ensuremath{\mu}POP clock, which opens perspectives for further improvements of long-term clock stability, in view of future generations of miniature vapor-cell clocks with enhanced performances based on the DR scheme.

Physical Review Applied•Nov 14, 2022•34 citations

Compact ultra-cold and thermal atomic clocks with stabilities better than part-per-trillion at one second

Erling Riis, Paul F. Griffin

In this talk, I will outline two stands of our ongoing atomic clock research at the University of Strathclyde, aimed at achieving short-term stabilities surpassing 1e-12 in portable systems. Firstly, I present a cold-atom microwave clock that integrates a grating-MOT within an additively manufactured microwave cavity, enabling a compact and potentially highly stable portable system. The work examines noise minimisation techniques through direct comparison with a cold-atom coherent population trapping (CPT) clock. I will also discuss progress on two-photon rubidium clocks based on MEMS vapour cells with integrated optics. The results highlight their prospects for resilient PNT applications and scalable deployment.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Systematic shifts in chip-scale atomic beam clocks

Gabriela D. Martinez, Alexander L. Staron, John E. Kitching +2 more

We report on progress in the characterization of systematic shifts in chip-scale atomic beam clocks, which offer the potential for improved long-term stability relative to existing chip-scale atomic clocks. Previous work has demonstrated the key features of chip-scale atomic beam devices including the use of a microfabricated Si/glass atomic beam cell, passively maintained vacuum environment, and an integrated Rb atomic beam source. A beam clock has been realized using Ramsey coherent population trapping interrogation with a demonstrated short-term fractional frequency stability of ≈ 1.2 × 10^(-9)at 1 s of integration. In this talk, we discuss the path toward long-term stabilty in chip-scale atomic beam clocks and leading clock systematics. Chip-scale atomic beams are a new platform for quantum sensing which offer the potential for long-term stability in compact, low-power applications.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations
The convergence of atomic spectroscopy, MEMS cell technologies and integrated photonics has led to the deployment of high-precision chip-scale atomic devices [1]. In this talk, we will present in-progress studies at FEMTO-ST Institute, France, for the development of microcellbased microwave and optical atomic clocks, with enhanced stability performances. In the first part, we will talk about the demonstration of CPT-based microwave cell clocks with stability at 1 day in the low 10−12 range [2], made possible thanks to the combination of advanced Ramsey-based interrogation sequences [3] and cells built with low gas permeation windows [4-5]. In the second part, we will discuss the in-progress development of a microcell-based optical frequency reference based on the two-photon transition of Rb atom at 778 nm. An encouraging short-term stability of 3 × 10−13 at 1 s and 3 × 10−14 at 100 s has been recently achieved [6]. Future studies will be briefly discussed.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.
We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.
We demonstrate and study a microcell microwave atomic clock based on optical-microwave double resonance (DR) interrogation operated in a pulsed Ramsey scheme, called the \ensuremath{\mu}POP clock, based on a microfabricated Rb vapor cell and a micro-loop-gap microwave resonator. For the mm-scale dimensions of this cell, the population and coherence relaxation rates of the Rb clock transition are on the order of 4--5 kHz, which puts constraints on the useful Ramsey times and overall pulse sequence in view of optimized clock performance. Our proof-of-principle demonstration of the \ensuremath{\mu}POP clock shows that the pulsed DR approach is nevertheless feasible and results in a short-term clock stability of 1 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}11}$ \ensuremath{\tau}${}^{\ensuremath{-}1/2}$ and reaching the \ensuremath{\le}2 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ level at timescales of 1000 s to one day. The short-term instability budget established for the \ensuremath{\mu}POP clock shows that the main limitation to the short-term stability arises from the detection noise. Thanks to the pulsed Ramsey scheme, light-shift effects are strongly reduced in the \ensuremath{\mu}POP clock, which opens perspectives for further improvements of long-term clock stability, in view of future generations of miniature vapor-cell clocks with enhanced performances based on the DR scheme.
In this talk, I will outline two stands of our ongoing atomic clock research at the University of Strathclyde, aimed at achieving short-term stabilities surpassing 1e-12 in portable systems. Firstly, I present a cold-atom microwave clock that integrates a grating-MOT within an additively manufactured microwave cavity, enabling a compact and potentially highly stable portable system. The work examines noise minimisation techniques through direct comparison with a cold-atom coherent population trapping (CPT) clock. I will also discuss progress on two-photon rubidium clocks based on MEMS vapour cells with integrated optics. The results highlight their prospects for resilient PNT applications and scalable deployment.
We report on progress in the characterization of systematic shifts in chip-scale atomic beam clocks, which offer the potential for improved long-term stability relative to existing chip-scale atomic clocks. Previous work has demonstrated the key features of chip-scale atomic beam devices including the use of a microfabricated Si/glass atomic beam cell, passively maintained vacuum environment, and an integrated Rb atomic beam source. A beam clock has been realized using Ramsey coherent population trapping interrogation with a demonstrated short-term fractional frequency stability of ≈ 1.2 × 10^(-9)at 1 s of integration. In this talk, we discuss the path toward long-term stabilty in chip-scale atomic beam clocks and leading clock systematics. Chip-scale atomic beams are a new platform for quantum sensing which offer the potential for long-term stability in compact, low-power applications.