Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Photonics Research

Compact optical frequency standard using a wafer-level MEMS vapor cell

Qiaohui Yang, Zhenyu Hu, Tian Liu, Jie Miao, Pengyuan Chang, Duo Pan, Zhiwei Li, Xianlong Wei, Jingbiao Chen

Published Jun 12, 2025• 10 citations
Publisher

Abstract

Atomic clocks represent the most advanced instruments for providing time-frequency standards, with increasing demand for designs that offer high frequency stability while minimizing size. Central to an atomic clock’s function is the atomic vapor cell, which serves as the quantum reference. Compared to traditional cells, wafer-level micro-electro-mechanical systems (MEMS) vapor cells enable cost-effective, scalable production and facilitate integration with silicon-based chips. In this work, we present a wafer-level MEMS vapor cell featuring an innovative silicon-glass-silicon transverse optical path structure. A single wafer is used to fabricate 24 identical atomic vapor cells, each with precise dimensions of 14 mm×14 mm×4.3 mm, ensuring scalability. We demonstrate an optical frequency standard that combines modulation transfer spectroscopy (MTS) with a MEMS vapor cell, featuring a compact design with excellent performance. This frequency standard achieves stability over averaging times of 1–400 s, with short-term stability of 2.6×10 −13 at 1 s and 5.1×10 −14 at 200 s. The laser linewidth is only 3.9 kHz, marking a substantial improvement over existing thermal standards, and opening potential applications in navigation, radar, and precision measurement. This work provides a crucial step toward the development of chip-scale optical clocks.

DOI
10.1364/prj.563033

Related papers

Compact Optical Frequency Standard with MEMS Vapor Cells

Qiaohui Yang, Zhenyu Hu, Tianyu Liu +7 more

This work introduces an innovative optical frequency standard that leverages MEMS vapor cells to achieve exceptional stability. To attain these objectives, we have integrated the modulation transfer spectroscopy (MTS) technique, which not only ensures high stability but also contributes to minimal power consumption in a compact form factor. Employing MTS with a high signal-to-noise ratio and utilizing a full bandwidth, high-speed servo feedback, we have successfully stabilized the laser frequency at the hyperfine transitions of rubidium atomic lines within the MEMS vapor cell. Furthermore, after the laser is locked, there is a significant narrowing effect on the laser linewidth. The current specifications of our compact optical frequency standard include a frequency Allan deviation of 4.8E-13@1s and the laser linewidth of only 18 kHz.

European Frequency and Time Forum•Jun 25, 2024•0 citations

Compact optical frequency standard based on a miniature cell using modulation transfer spectroscopy

Jiqing Lian, Qiaohui Yang, Tianyu Liu +8 more

This study investigates the application of miniature quantum references within small-scale optical atomic frequency standards, utilizing a diminutive 87 Rb glass cell, dimensions of 6 mm × 6 mm × 6 mm, to establish a quantum frequency standard.By employing the transition spectrum from 5 2 S 1/2 F = 2 to 5 2 P 3/2 F 0 =3, this study successfully demonstrates the development of a compact rubidium atomic optical frequency standard via modulation transfer spectroscopy (MTS).Subsequent to frequency stabilization, the 780 nm clock laser exhibits a linewidth of 6.9 kHz, and its out-of-loop short-term stability reaches 4.1 × 10 -13 @ 1 s, as confirmed through beat frequency analysis.This research not only provides a practical blueprint for the development of small optical atomic frequency standards but also lays down essential groundwork for future advancements in chip-level optical frequency standard technologies.

Chinese Optics Letters•Jan 1, 2025•2 citations

Saturated absorption spectroscopy of the near-UV Cs atom 6S1/2-7P1/2 transition in a MEMS vapor cell

Emmanuel Klinger, C. M. Rivera-Aguilar, Rémy Vicarini +2 more

Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices, such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping. It has offered in its industrial and commercialized version an ultra-low size-power-instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s.Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 − 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fullyminiaturized and low-power optical clock.In this work, we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 – 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance. Latest results will be presented at the conference.

•Jun 25, 2024•0 citations

MEMS vapor cells-based Rydberg-atom electrometry toward miniaturization and high sensitivity

Yintao Ma, Pan Chen, Mingzhi Yu +7 more

Rydberg-atom electrometry, as an emerging cutting-edge technology, features high sensitivity, broad bandwidth, calibration-free operation, and beyond. However, until now the key atomic vapor cells used for confining electric field-sensitive Rydberg atoms nearly made with traditional glass-blown techniques, hindering the miniaturization, integration, and batch manufacturing. Here, we present the wafer-level MEMS atomic vapor cells with glass-silicon-glass sandwiched structure that are batch-manufactured for both frequency stability and electric field measurement. We use specially customized ultra-thick silicon wafers with a resistivity exceeding 10,000 Ω cm, three orders of magnitude higher than that of typical silicon, and a thickness of 6 mm, providing a 4-fold improvement in optical interrogation length. With the as-developed MEMS atomic vapor cell, we configured a high-sensitivity Rydberg-atom electrometry with the minimal detectable microwave field to be 2.8 mV/cm. This combination of miniaturization and sensitivity represents a significant advance in the state-of-the-art field of Rydberg-atom electrometry, paving the way for chip-scale Rydberg-atom electrometry and potentially opening up new applications in a wider variety of fields.

arXiv:2509.01911•Microsystems & Nanoengineering•Jun 10, 2026•1 citation

Saturated absorption spectroscopy of the Cs atom 6S1/2 → 7P1/2 transition at 459 nm in a microfabricated vapor cell

Emmanuel Klinger, Andrei Mursa, C. M. Rivera-Aguilar +3 more

Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.

•Sep 30, 2024•0 citations

Micro-fabricated caesium vapor cell with 5 mm optical path length

T. Dyer, Stuart J. Ingleby, Camelia C. Dunare +4 more

Micro-fabricated vapor cells have applications in a number of emerging quantum technology-based devices including miniaturized atomic magnetometers, atomic clocks, and frequency references for laser systems. Increasing the cell optical path length (OPL) and smallest cell dimension are normally desirable to increase the signal to noise ratio (SNR) and minimize the de-polarization rate due to collisions between atomic or molecular species and the cell walls. This paper presents a fully wafer-level scalable fabrication process to manufacture vapor cells with dimensions approaching those of glass-blown cells. The fabrication process is described, and spectroscopic measurements (optical absorption and magnetic resonance) are reported. A magnetic resonance linewidth of 350 Hz is demonstrated, and this is the smallest linewidth reported to date for a micro-fabricated vapor cell.

Journal of Applied Physics•Nov 22, 2022•14 citations
Atomic clocks represent the most advanced instruments for providing time-frequency standards, with increasing demand for designs that offer high frequency stability while minimizing size. Central to an atomic clock’s function is the atomic vapor cell, which serves as the quantum reference. Compared to traditional cells, wafer-level micro-electro-mechanical systems (MEMS) vapor cells enable cost-effective, scalable production and facilitate integration with silicon-based chips. In this work, we present a wafer-level MEMS vapor cell featuring an innovative silicon-glass-silicon transverse optical path structure. A single wafer is used to fabricate 24 identical atomic vapor cells, each with precise dimensions of 14 mm×14 mm×4.3 mm, ensuring scalability. We demonstrate an optical frequency standard that combines modulation transfer spectroscopy (MTS) with a MEMS vapor cell, featuring a compact design with excellent performance. This frequency standard achieves stability over averaging times of 1–400 s, with short-term stability of 2.6×10 −13 at 1 s and 5.1×10 −14 at 200 s. The laser linewidth is only 3.9 kHz, marking a substantial improvement over existing thermal standards, and opening potential applications in navigation, radar, and precision measurement. This work provides a crucial step toward the development of chip-scale optical clocks.
This work introduces an innovative optical frequency standard that leverages MEMS vapor cells to achieve exceptional stability. To attain these objectives, we have integrated the modulation transfer spectroscopy (MTS) technique, which not only ensures high stability but also contributes to minimal power consumption in a compact form factor. Employing MTS with a high signal-to-noise ratio and utilizing a full bandwidth, high-speed servo feedback, we have successfully stabilized the laser frequency at the hyperfine transitions of rubidium atomic lines within the MEMS vapor cell. Furthermore, after the laser is locked, there is a significant narrowing effect on the laser linewidth. The current specifications of our compact optical frequency standard include a frequency Allan deviation of 4.8E-13@1s and the laser linewidth of only 18 kHz.
This study investigates the application of miniature quantum references within small-scale optical atomic frequency standards, utilizing a diminutive 87 Rb glass cell, dimensions of 6 mm × 6 mm × 6 mm, to establish a quantum frequency standard.By employing the transition spectrum from 5 2 S 1/2 F = 2 to 5 2 P 3/2 F 0 =3, this study successfully demonstrates the development of a compact rubidium atomic optical frequency standard via modulation transfer spectroscopy (MTS).Subsequent to frequency stabilization, the 780 nm clock laser exhibits a linewidth of 6.9 kHz, and its out-of-loop short-term stability reaches 4.1 × 10 -13 @ 1 s, as confirmed through beat frequency analysis.This research not only provides a practical blueprint for the development of small optical atomic frequency standards but also lays down essential groundwork for future advancements in chip-level optical frequency standard technologies.
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices, such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping. It has offered in its industrial and commercialized version an ultra-low size-power-instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s.Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 − 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fullyminiaturized and low-power optical clock.In this work, we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 – 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance. Latest results will be presented at the conference.
Rydberg-atom electrometry, as an emerging cutting-edge technology, features high sensitivity, broad bandwidth, calibration-free operation, and beyond. However, until now the key atomic vapor cells used for confining electric field-sensitive Rydberg atoms nearly made with traditional glass-blown techniques, hindering the miniaturization, integration, and batch manufacturing. Here, we present the wafer-level MEMS atomic vapor cells with glass-silicon-glass sandwiched structure that are batch-manufactured for both frequency stability and electric field measurement. We use specially customized ultra-thick silicon wafers with a resistivity exceeding 10,000 Ω cm, three orders of magnitude higher than that of typical silicon, and a thickness of 6 mm, providing a 4-fold improvement in optical interrogation length. With the as-developed MEMS atomic vapor cell, we configured a high-sensitivity Rydberg-atom electrometry with the minimal detectable microwave field to be 2.8 mV/cm. This combination of miniaturization and sensitivity represents a significant advance in the state-of-the-art field of Rydberg-atom electrometry, paving the way for chip-scale Rydberg-atom electrometry and potentially opening up new applications in a wider variety of fields.
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.
Micro-fabricated vapor cells have applications in a number of emerging quantum technology-based devices including miniaturized atomic magnetometers, atomic clocks, and frequency references for laser systems. Increasing the cell optical path length (OPL) and smallest cell dimension are normally desirable to increase the signal to noise ratio (SNR) and minimize the de-polarization rate due to collisions between atomic or molecular species and the cell walls. This paper presents a fully wafer-level scalable fabrication process to manufacture vapor cells with dimensions approaching those of glass-blown cells. The fabrication process is described, and spectroscopic measurements (optical absorption and magnetic resonance) are reported. A magnetic resonance linewidth of 350 Hz is demonstrated, and this is the smallest linewidth reported to date for a micro-fabricated vapor cell.