Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement Science and Technology

Static bias magnetic field assisted optical modulation triaxial SERF atomic magnetometer

Xiaoyu Li, Bangcheng Han, Shushan Gao, Ziao Liu, Zhongyu Wang, Jianwei Sheng, Jixi Lu

Published Nov 7, 2025• 2 citations
Publisher

Abstract

Abstract High-sensitivity triaxial magnetic field measurements are crucial in various scientific and industrial applications, with spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) standing out for their exceptional sensitivity. However, conventional methods for achieving triaxial measurements in SERF magnetometers typically involve multiple modulated magnetic fields, which introduce crosstalk challenges in array-based configurations. We propose a static bias magnetic field assisted optical modulation triaxial AM to address this limitation. In this configuration, the detuned circularly polarized light is utilized to achieve synchronous modulation of the fictitious magnetic field and pumping rate while incorporating a static bias magnetic field to generate a transverse projection component. We develop a comprehensive triaxial response model that fully considers the effects of the longitudinal spin polarization deflection. Building upon this model, we derive the relationship between the transverse spin component and the triaxial magnetic field and introduce parameter optimization methods to obtain optimal parameters, thus enabling triaxial measurements of 12 fT Hz −1/2 , 10 fT Hz −1/2 , and 15 fT Hz −1/2 along the x-, y -, and z -axes. Our approach offers significant advantages over existing methods, particularly in minimizing crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Moreover, the effective detection of simulated magnetocardiography signals highlights the practical applicability and reliability of the proposed method in real-world scenarios.

DOI
10.1088/1361-6501/ae1cda

Related papers

Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer

Shushan Gao, Xiaoyu Li, Jianwei Sheng +5 more

The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz${}^{\text {1/2}}$for the$x$- and$y$-axes, and a longitudinal sensitivity of 70 fT/Hz${}^{\text {1/2}}$for the$z$-axis in a$4\times 4\times 4$mm${}^{\text {3 87}}$Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Oct 24, 2022•23 citations

Detuned square-wave optical modulation zero-field atomic magnetometer

Xiaoyu Li, Bangcheng Han, Jixi Lu +2 more

In recent years, arrayed atomic magnetometers have been continuously applied in biomagnetic scenarios. However, the crosstalk between adjacent sensors introduced by the modulated magnetic fields significantly compromises the imaging accuracy of arrayed atomic magnetometers. To solve this problem, a detuned square-wave optical modulation zero-field atomic magnetometer configuration is developed and we provide an analytical solution of this method. In this scheme, the circularly polarized pump light is used to polarize alkali metal atoms longitudinally, and a beam of detuned square-wave modulated circularly polarized light is applied transversely to generate a light-shift modulation instead of the coil-generated modulated magnetic field. Then the transverse magnetic field is measured by the optical absorption method of longitudinally circularly polarized pump light. This scheme maintains the inherent advantage of high sensitivity in spinexchange relaxation-free (SERF) atomic magnetometers. Additionally, the all-optical configuration eliminates the need for additional modulated magnetic fields or radio frequency (RF) fields, thereby mitigating crosstalk issues associated with modulated magnetic fields in array applications. Consequently, this scheme exhibits great potential for arraying and is expected to be employed in magnetocardiography (MCG) and magnetoencephalography (MEG).

Optics Young Scientist Summit (OYSS)•Dec 29, 2023•0 citations

Fast In-Situ Triaxial Remanent Magnetic Field Measurement for Single-Beam SERF Atomic Magnetometer Based on Trisection Algorithm

Tengyue Long, Bangcheng Han, Xinda Song +3 more

Abstract We demonstrate a method for quickly and automatically detecting all three components of a remanent magnetic field around a shielded spin-exchange relaxation-free (SERF) atomic magnetometer (AM) using the trisection algorithm (TSA) for zero-field resonance (ZFR). To satisfy the measurement of AMs, a resonance light of the 87 Rb D1 line with a spectral width of less than 1MHz is converted to circular polarization by a linear polarizer and a quarter-wave plate. After the light beam has passed through the alkali metal vapor cell, the residual magnetic field can be measured by searching for triaxial ZFR optical peaks. The TSA stably reduces the measurement time to 2.41 s on average and improves the measurement accuracy, significantly outpacing existing methods. The weighted averages of all measurements with corresponding uncertainties are (−15.437 ± 0.022)nT, (6.062 ± 0.021)nT, and (−14.158 ± 0.052)nT on the x -, y -, and z -axes, respectively. These improvements could facilitate more extremely weak magnetic studies in real time, such as magnetoencephalography (MEG) and magnetocardiography (MCG) measurements.

Photonic Sensors•Jan 1, 2022•28 citations

A Triaxial Dual‐Beam Magnetic Measurement Method Based on Dressed‐Atom Dynamic Evolution Behavior for Miniaturized SERF Atomic Magnetometer

Zhen Li, Xiangyang Zhou, Zihao Lyu +4 more

ABSTRACT Miniaturized spin‐exchange relaxation‐free (SERF) atomic magnetometers have become core sensors for detecting biomagnetic fields, including MEG and MCG, due to their ultra‐high sensitivity and high spatiotemporal resolution. Compared to single‐axis magnetometers, triaxial atomic magnetometers are more attractive which can measure comprehensive three‐dimensional magnetic field information. However, traditional triaxial single‐beam or dual‐beam configurations are constrained by limited longitudinal sensitivity or complex optical architectures unsuitable for miniaturized sensors. In this paper, a triaxial dual‐beam magnetic measurement method based on the dynamic evolution of dressed atoms is proposed. The proposed method employs an overlapping pump–probe configuration to simplify the optical sensing architecture while maintaining high magnetic field sensitivity. By utilizing multi‐frequency signal modulation and parallel demodulation, triaxial magnetic vector components are measured simultaneously. Modulation parameters are experimentally optimized based on a systematic analysis of atomic spin dynamics under dual radio‐frequency (RF) fields. Triaxial couplings under various bias magnetic fields are quantitatively analyzed. Experimental validation using a 4 mm vapor cell demonstrates simultaneous triaxial magnetic field measurements, achieving sensitivities of 84.4, 73.2, and 190.7 fT/Hz 1/2 and corresponding bandwidths of 65, 76, and 78 Hz along the x ‐, y ‐, and z ‐axes, respectively.

Advanced Quantum Technologies•Nov 1, 2026•0 citations

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•3 citations
Abstract High-sensitivity triaxial magnetic field measurements are crucial in various scientific and industrial applications, with spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) standing out for their exceptional sensitivity. However, conventional methods for achieving triaxial measurements in SERF magnetometers typically involve multiple modulated magnetic fields, which introduce crosstalk challenges in array-based configurations. We propose a static bias magnetic field assisted optical modulation triaxial AM to address this limitation. In this configuration, the detuned circularly polarized light is utilized to achieve synchronous modulation of the fictitious magnetic field and pumping rate while incorporating a static bias magnetic field to generate a transverse projection component. We develop a comprehensive triaxial response model that fully considers the effects of the longitudinal spin polarization deflection. Building upon this model, we derive the relationship between the transverse spin component and the triaxial magnetic field and introduce parameter optimization methods to obtain optimal parameters, thus enabling triaxial measurements of 12 fT Hz −1/2 , 10 fT Hz −1/2 , and 15 fT Hz −1/2 along the x-, y -, and z -axes. Our approach offers significant advantages over existing methods, particularly in minimizing crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Moreover, the effective detection of simulated magnetocardiography signals highlights the practical applicability and reliability of the proposed method in real-world scenarios.
The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz1/2{}^{\text {1/2}}1/2for thexxx- andyyy-axes, and a longitudinal sensitivity of 70 fT/Hz1/2{}^{\text {1/2}}1/2for thezzz-axis in a4×4×44\times 4\times 44×4×4mm3 87{}^{\text {3 87}}3 87Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.
Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
In recent years, arrayed atomic magnetometers have been continuously applied in biomagnetic scenarios. However, the crosstalk between adjacent sensors introduced by the modulated magnetic fields significantly compromises the imaging accuracy of arrayed atomic magnetometers. To solve this problem, a detuned square-wave optical modulation zero-field atomic magnetometer configuration is developed and we provide an analytical solution of this method. In this scheme, the circularly polarized pump light is used to polarize alkali metal atoms longitudinally, and a beam of detuned square-wave modulated circularly polarized light is applied transversely to generate a light-shift modulation instead of the coil-generated modulated magnetic field. Then the transverse magnetic field is measured by the optical absorption method of longitudinally circularly polarized pump light. This scheme maintains the inherent advantage of high sensitivity in spinexchange relaxation-free (SERF) atomic magnetometers. Additionally, the all-optical configuration eliminates the need for additional modulated magnetic fields or radio frequency (RF) fields, thereby mitigating crosstalk issues associated with modulated magnetic fields in array applications. Consequently, this scheme exhibits great potential for arraying and is expected to be employed in magnetocardiography (MCG) and magnetoencephalography (MEG).
Abstract We demonstrate a method for quickly and automatically detecting all three components of a remanent magnetic field around a shielded spin-exchange relaxation-free (SERF) atomic magnetometer (AM) using the trisection algorithm (TSA) for zero-field resonance (ZFR). To satisfy the measurement of AMs, a resonance light of the 87 Rb D1 line with a spectral width of less than 1MHz is converted to circular polarization by a linear polarizer and a quarter-wave plate. After the light beam has passed through the alkali metal vapor cell, the residual magnetic field can be measured by searching for triaxial ZFR optical peaks. The TSA stably reduces the measurement time to 2.41 s on average and improves the measurement accuracy, significantly outpacing existing methods. The weighted averages of all measurements with corresponding uncertainties are (−15.437 ± 0.022)nT, (6.062 ± 0.021)nT, and (−14.158 ± 0.052)nT on the x -, y -, and z -axes, respectively. These improvements could facilitate more extremely weak magnetic studies in real time, such as magnetoencephalography (MEG) and magnetocardiography (MCG) measurements.
ABSTRACT Miniaturized spin‐exchange relaxation‐free (SERF) atomic magnetometers have become core sensors for detecting biomagnetic fields, including MEG and MCG, due to their ultra‐high sensitivity and high spatiotemporal resolution. Compared to single‐axis magnetometers, triaxial atomic magnetometers are more attractive which can measure comprehensive three‐dimensional magnetic field information. However, traditional triaxial single‐beam or dual‐beam configurations are constrained by limited longitudinal sensitivity or complex optical architectures unsuitable for miniaturized sensors. In this paper, a triaxial dual‐beam magnetic measurement method based on the dynamic evolution of dressed atoms is proposed. The proposed method employs an overlapping pump–probe configuration to simplify the optical sensing architecture while maintaining high magnetic field sensitivity. By utilizing multi‐frequency signal modulation and parallel demodulation, triaxial magnetic vector components are measured simultaneously. Modulation parameters are experimentally optimized based on a systematic analysis of atomic spin dynamics under dual radio‐frequency (RF) fields. Triaxial couplings under various bias magnetic fields are quantitatively analyzed. Experimental validation using a 4 mm vapor cell demonstrates simultaneous triaxial magnetic field measurements, achieving sensitivities of 84.4, 73.2, and 190.7 fT/Hz 1/2 and corresponding bandwidths of 65, 76, and 78 Hz along the x ‐, y ‐, and z ‐axes, respectively.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.