Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Advancing Optical Lattice Clocks: Accurate Measurements on a Bosonic System and Development of a Hybrid Cavity-Lattice Clock

Juan Pablo Salvatierra

Published May 27, 2026• 0 citations
OpenAlex

Abstract

This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .

Related papers

Status and Perspectives of INRIM Sr Cavity-Enhanced Optical Clock

Matteo Barbiero, Gianluca Bertaina, Davide Calonico +3 more

We report on the status of the strontium optical lattice clock at INRIM and its development towards a cavity-enhanced optical frequency standard exploiting quantum techniques. We have recently developed a novel method to perform high-fidelity spectral purity transfer based on serrodyne optical frequency shifting. We estimated the phase noise induced by the modulation setup by developing a novel composite self-heterodyne interferometer. The consequent short-term stability of our clock is presented, showing collision-limited interaction time in the bosonic88Sr clock. We also outline the progress towards a cavity-enhanced optical lattice clock. We present a numerical study on collective spin-squeezed states produced by QND continuous measurement of a lossy cavity and its relevance for a Sr optical lattice clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations

Development of an Apparatus for a Strontium Optical Lattice Optical Frequency Standard

Ian R. Hill

Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.

•Jun 1, 2012•3 citations

Spectroscopy schemes for improved optical clock stability

Filip Butuc-Mayer

Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.

•Jan 1, 2026•0 citations

Understanding atomic interactions in an optical lattice clock and using them to study many-body physics

Michael Bishof

Strontium optical lattice clocks at JILA recently demonstrated record-high accuracy and stability. These advances were enabled by an ultrastable laser with fractional frequency stability of 1x10-16 at 1 second. This laser allows us to study systematic shifts of the 1S0 to 3P0 clock transition with unprecedented precision. Density-dependent frequency shifts represent an unavoidable perturbation for clocks based on many atoms. Our studies of atomic interactions in an optical lattice clock system uncover the nature of these interactions and reveal important many-body atomic correlation effects in this open quantum system. By extending our measurements to all ten nuclear-spin sublevels of the clock states, we observe the first direct evidence of SU(N) symmetric interactions in alkaline earth(-like) atoms. Using the techniques we developed in these studies, we also demonstrate a novel technique for measuring the frequency noise spectrum of an ultrastable laser. We discuss designs for the future direction of our experiment which will place 87Sr atoms within a high finesse cavity that is resonant on the 1S0 to 3P1 transition. We will use this system to study collective effects in cavity quantum electrodynamics. Most notably, strong atom-cavity coupling can enhance the spectroscopic sensitivity of our clock by creating spin-squeezed states via quantum non-demolition measurements. As a precursor to future work studying cavity-mediated collective behavior, we use the unique atomic structure of 88Sr to investigate free-space retarded dipolar coupling in an optically thick sample of atoms.

•Jan 1, 2014•0 citations

An optical lattice clock with neutral strontium

Richard Hobson

Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.

•Jan 1, 2016•9 citations

A high-performance bosonic optical lattice clock

Stefano Origlia

Optical clocks are being developed worldwide and are at the forefront of frequency metrology. Today they outperform microwave clocks instability and inaccuracy by two orders of magnitude, raising discussion about the redefinition of the SI second. Their outstanding performances are paving the way to applications in different fields apart from metrology. Optical clocks can be used for geodetic measurements, such as chronometric levelling, and fundamental physics experiments. These applications require transportable, and even space-born optical clocks that are in development. Space optical clocks will serve as a high accurate references for intercontinental clock comparisons, and will also provide a unique test bench for fundamental physics theories, such as Einstein’s prediction of time dilation and equivalence principle. This work presents the development and characterization of a transportable strontium optical lattice clock, realised in the framework of the ESA I-SOC (Space Optical Clock on the ISS) mission. The aim of the project is to investigate new technologies and techniques, in order to develop a robust apparatus as demonstrator for space applications. Special effort has been made to reduce the size and weight of the clock, so as to meet the stringent requirements of a space mission. The system reported here is one of the most compact optical clock to date, with a total volume of only 1 m3, excluding electronics. The clock is operated with the strontium bosonic isotope 88Sr: this is preferable to the fermionic counterpart 87Sr, commonly used in optical lattice clocks, if simplicity and reliability are required. However, in terms of accuracy, bosonic clocks present some disadvantages compared with the fermionic ones, which have significantly slowed down their development for metrological applications. We characterised the relevant operating parameters and their effect on the clock accuracy and instability. Exploiting a clock laser offering an outstanding stability, we were able to demonstrate a clock fractional instability of 3×10-18 , and an inaccuracy of 2×10-17: both values represent a factor of 30 improvement compared with previous works on bosonic optical clocks. These results suggest that, in the near future, bosonic clocks may become competitive to their fermionic counterparts. This is of interest for applications such as time scale realization, transportable clocks, or for test of fundamental physics. As an example, we measured the 88Sr-87Sr isotope shift, with an uncertainty of 12 mHz.

•Jan 1, 2018•1 citation
This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .
We report on the status of the strontium optical lattice clock at INRIM and its development towards a cavity-enhanced optical frequency standard exploiting quantum techniques. We have recently developed a novel method to perform high-fidelity spectral purity transfer based on serrodyne optical frequency shifting. We estimated the phase noise induced by the modulation setup by developing a novel composite self-heterodyne interferometer. The consequent short-term stability of our clock is presented, showing collision-limited interaction time in the bosonic88Sr clock. We also outline the progress towards a cavity-enhanced optical lattice clock. We present a numerical study on collective spin-squeezed states produced by QND continuous measurement of a lossy cavity and its relevance for a Sr optical lattice clock.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.
Strontium optical lattice clocks at JILA recently demonstrated record-high accuracy and stability. These advances were enabled by an ultrastable laser with fractional frequency stability of 1x10-16 at 1 second. This laser allows us to study systematic shifts of the 1S0 to 3P0 clock transition with unprecedented precision. Density-dependent frequency shifts represent an unavoidable perturbation for clocks based on many atoms. Our studies of atomic interactions in an optical lattice clock system uncover the nature of these interactions and reveal important many-body atomic correlation effects in this open quantum system. By extending our measurements to all ten nuclear-spin sublevels of the clock states, we observe the first direct evidence of SU(N) symmetric interactions in alkaline earth(-like) atoms. Using the techniques we developed in these studies, we also demonstrate a novel technique for measuring the frequency noise spectrum of an ultrastable laser. We discuss designs for the future direction of our experiment which will place 87Sr atoms within a high finesse cavity that is resonant on the 1S0 to 3P1 transition. We will use this system to study collective effects in cavity quantum electrodynamics. Most notably, strong atom-cavity coupling can enhance the spectroscopic sensitivity of our clock by creating spin-squeezed states via quantum non-demolition measurements. As a precursor to future work studying cavity-mediated collective behavior, we use the unique atomic structure of 88Sr to investigate free-space retarded dipolar coupling in an optically thick sample of atoms.
Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.
Optical clocks are being developed worldwide and are at the forefront of frequency metrology. Today they outperform microwave clocks instability and inaccuracy by two orders of magnitude, raising discussion about the redefinition of the SI second. Their outstanding performances are paving the way to applications in different fields apart from metrology. Optical clocks can be used for geodetic measurements, such as chronometric levelling, and fundamental physics experiments. These applications require transportable, and even space-born optical clocks that are in development. Space optical clocks will serve as a high accurate references for intercontinental clock comparisons, and will also provide a unique test bench for fundamental physics theories, such as Einstein’s prediction of time dilation and equivalence principle. This work presents the development and characterization of a transportable strontium optical lattice clock, realised in the framework of the ESA I-SOC (Space Optical Clock on the ISS) mission. The aim of the project is to investigate new technologies and techniques, in order to develop a robust apparatus as demonstrator for space applications. Special effort has been made to reduce the size and weight of the clock, so as to meet the stringent requirements of a space mission. The system reported here is one of the most compact optical clock to date, with a total volume of only 1 m3, excluding electronics. The clock is operated with the strontium bosonic isotope 88Sr: this is preferable to the fermionic counterpart 87Sr, commonly used in optical lattice clocks, if simplicity and reliability are required. However, in terms of accuracy, bosonic clocks present some disadvantages compared with the fermionic ones, which have significantly slowed down their development for metrological applications. We characterised the relevant operating parameters and their effect on the clock accuracy and instability. Exploiting a clock laser offering an outstanding stability, we were able to demonstrate a clock fractional instability of 3×10-18 , and an inaccuracy of 2×10-17: both values represent a factor of 30 improvement compared with previous works on bosonic optical clocks. These results suggest that, in the near future, bosonic clocks may become competitive to their fermionic counterparts. This is of interest for applications such as time scale realization, transportable clocks, or for test of fundamental physics. As an example, we measured the 88Sr-87Sr isotope shift, with an uncertainty of 12 mHz.