Chinese Physics Letters

Improved Evaluation of BBR and Collisional Frequency Shifts of NIM-Sr2 with 7.2 × 10−18 Total Uncertainty

Bing-Kun Lu, Zhen Guo Sun, Tao Yang, Yige Lin, Qiang Wang, Ye Li, Fei Meng, Bai-Ke Lin, Tianchu Li, Zhanjun Fang

Published Jul 1, 2022• 28 citations
Publisher

Abstract

NIM-Sr2 optical lattice clock has been developed on the Changping campus of National Institute of Metrology (NIM). Considering the limitations in NIM-Sr1, several improved parts have been designed including a differential pumping stage in the vacuum system, a permanent magnet Zeeman slower, water-cooled anti-Helmholtz coils, an extended viewport for Zeeman slower, etc. A clock laser with a short-time stability better than 3 × 10−16 is realized based on a self-designed 30-cm-long ultra-low expansion cavity. The systematic frequency shift has been evaluated to an uncertainty of 7.2 × 10−18, with the uncertainty of BBR shift and the collisional frequency shift being an order of magnitude lower than the last evaluation of NIM-Sr1.

DOI
10.1088/0256-307x/39/8/080601

Related papers

DEVELOPMENT OF AN OPTICAL CLOCK BASED ON NEUTRAL STRONTIUM ATOMS HELD IN A LATTICE TRAP

E. A. Curtis, Yuri B. Ovchinnikov, Ian R. Hill +2 more

At the National Physical Laboratory we are developing a neutral atom optical clock based on strontium atoms held in an optical lattice during the clock frequency measurement. The innovation of lattice-type clocks has greatly reduced velocity-related systematic frequency shifts compared to ballistic expansion neutral atom clocks. However, with predicted fractional uncertainties as low as 10 -18 , many previously unexplored systematic effects become relevant, especially in dealing with shifts due to blackbody radiation. We are designing a compact, diode-laser-based system, with a view to future transportable systems, and which includes a novel permanent-magnet-based Zeeman slower and a blackbody measurement chamber.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

An Yb optical lattice clock: Current status at KRISS

Dai-Hyuk Yu, Chang Yong Park, Won-Kyu Lee +5 more

The current status of an Yb optical lattice clock at the Korea Research Institute of Standards and Science (KRISS) is reported. The systematic uncertainty of the Yb clock in the first accuracy evaluation was 1.5 × 10 −14 [Park et al. , Metrologia 50, 119 (2013)]. The uncertainty was dominated by the large uncertainties in the lattice ac Stark shift and the collisional shift, which were mainly limited by the large linewidth and jitter of the clock laser. Recently, a highly stable clock laser at 578 nm was developed with a short-term linewidth of 3.5 Hz and a frequency jitter of about 25 Hz at 1 s and 10 s measurement times, respectively. The long-term frequency drift showed only a linear dependence on time, confirming that the temperature of the super-cavity was maintained a zero coefficient of thermal expansion. The frequency of the lattice laser at 759 nm was phase locked to the optical frequency comb and could be stabilized at the “absolute” frequency of the “magic wavelength”, to within a 1-MHz uncertainty. This improvement greatly reduced the fractional uncertainty due to the lattice ac Stark shift down to 2 × 10 −16 . The systematic uncertainty of the clock is currently 5.3 × 10 −15 and is dominated by the collisional frequency shift.

Journal of the Korean Physical Society•Aug 1, 2013•12 citations

An improved strontium lattice clock with 10?16 level laser frequency stabilization

Ye Li, Yige Lin, Qiang Wang +4 more

A clock laser based on a 30-cm-long ultrahigh finesse optical cavity was developed to improve the frequency stability of the Sr optical lattice clock at the National Institute of Metrology. Using this clock laser to probe the spin-polarized Sr87 atoms, a Rabi transition linewidth of 1.8 Hz was obtained with 500 ms interrogation time. Two independent digital servos are used to alternatively lock the clock laser to the S01 (mF=+9/2)→P03 (mF=+9/2) transition. The Allan deviation shows that the short-term frequency stability is better than 3.2×10−16 and averages down followed by 1.8×10−15/τ.

Chinese Optics Letters•Jan 1, 2018•22 citations

Advancing Optical Lattice Clocks: Accurate Measurements on a Bosonic System and Development of a Hybrid Cavity-Lattice Clock

Juan Pablo Salvatierra

This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .

•May 27, 2026•0 citations

Towards a strontium based stationary optical lattice clock

Qasim Hassan Ubaid

Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.

•Jul 20, 2020•0 citations

The Development of the NIM-Yb1 Ion Optical Clock

Shaoyang Dai, Yani Zuo, Chaowei Wang +6 more

Optical clocks serve as the benchmark devices for the next-generation definition of the second and have significant applications in testing the theories beyong the standard models, dark matter research, and related fields.The ytterbium ion optical clock, featuring two clock transition lines, is among the most precise optical clocks with the lowest uncertainties.The National Institute of Metrology, China (NIM), initiated research on ytterbium ion optical clocks in 2021.Based on an end-cap ion trap, a vacuum system has been established.A 370 nm thirdharmonic fiber laser, along with 760 nm and 935 nm DFB lasers, ensures a stable operation of the optical system.To date, both the electric quadrupole and electric octupole clock transitions have been observed.A 2.8 Hz linewidth of the electric octupole transition has been achieved, with a stability of 1.7E-15 τ -1/2 after closed-loop locking.The uncertainties due to AC Starks shift from clock laser and second-order Doppler shifts are being evaluated, with an expected total uncertainty below 5E-18.

URSI Asia-Pacific Radio Science Conference•Jan 1, 2025•1 citation
NIM-Sr2 optical lattice clock has been developed on the Changping campus of National Institute of Metrology (NIM). Considering the limitations in NIM-Sr1, several improved parts have been designed including a differential pumping stage in the vacuum system, a permanent magnet Zeeman slower, water-cooled anti-Helmholtz coils, an extended viewport for Zeeman slower, etc. A clock laser with a short-time stability better than 3 × 10−16 is realized based on a self-designed 30-cm-long ultra-low expansion cavity. The systematic frequency shift has been evaluated to an uncertainty of 7.2 × 10−18, with the uncertainty of BBR shift and the collisional frequency shift being an order of magnitude lower than the last evaluation of NIM-Sr1.
At the National Physical Laboratory we are developing a neutral atom optical clock based on strontium atoms held in an optical lattice during the clock frequency measurement. The innovation of lattice-type clocks has greatly reduced velocity-related systematic frequency shifts compared to ballistic expansion neutral atom clocks. However, with predicted fractional uncertainties as low as 10 -18 , many previously unexplored systematic effects become relevant, especially in dealing with shifts due to blackbody radiation. We are designing a compact, diode-laser-based system, with a view to future transportable systems, and which includes a novel permanent-magnet-based Zeeman slower and a blackbody measurement chamber.
The current status of an Yb optical lattice clock at the Korea Research Institute of Standards and Science (KRISS) is reported. The systematic uncertainty of the Yb clock in the first accuracy evaluation was 1.5 × 10 −14 [Park et al. , Metrologia 50, 119 (2013)]. The uncertainty was dominated by the large uncertainties in the lattice ac Stark shift and the collisional shift, which were mainly limited by the large linewidth and jitter of the clock laser. Recently, a highly stable clock laser at 578 nm was developed with a short-term linewidth of 3.5 Hz and a frequency jitter of about 25 Hz at 1 s and 10 s measurement times, respectively. The long-term frequency drift showed only a linear dependence on time, confirming that the temperature of the super-cavity was maintained a zero coefficient of thermal expansion. The frequency of the lattice laser at 759 nm was phase locked to the optical frequency comb and could be stabilized at the “absolute” frequency of the “magic wavelength”, to within a 1-MHz uncertainty. This improvement greatly reduced the fractional uncertainty due to the lattice ac Stark shift down to 2 × 10 −16 . The systematic uncertainty of the clock is currently 5.3 × 10 −15 and is dominated by the collisional frequency shift.
A clock laser based on a 30-cm-long ultrahigh finesse optical cavity was developed to improve the frequency stability of the Sr optical lattice clock at the National Institute of Metrology. Using this clock laser to probe the spin-polarized Sr87 atoms, a Rabi transition linewidth of 1.8 Hz was obtained with 500 ms interrogation time. Two independent digital servos are used to alternatively lock the clock laser to the S01 (mF=+9/2)→P03 (mF=+9/2) transition. The Allan deviation shows that the short-term frequency stability is better than 3.2×10−16 and averages down followed by 1.8×10−15/τ.
This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .
Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.
Optical clocks serve as the benchmark devices for the next-generation definition of the second and have significant applications in testing the theories beyong the standard models, dark matter research, and related fields.The ytterbium ion optical clock, featuring two clock transition lines, is among the most precise optical clocks with the lowest uncertainties.The National Institute of Metrology, China (NIM), initiated research on ytterbium ion optical clocks in 2021.Based on an end-cap ion trap, a vacuum system has been established.A 370 nm thirdharmonic fiber laser, along with 760 nm and 935 nm DFB lasers, ensures a stable operation of the optical system.To date, both the electric quadrupole and electric octupole clock transitions have been observed.A 2.8 Hz linewidth of the electric octupole transition has been achieved, with a stability of 1.7E-15 τ -1/2 after closed-loop locking.The uncertainties due to AC Starks shift from clock laser and second-order Doppler shifts are being evaluated, with an expected total uncertainty below 5E-18.