Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Towards a strontium based stationary optical lattice clock

Qasim Hassan Ubaid

Published Jul 20, 2020• 0 citations
OpenAlex

Abstract

Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.

Related papers

Towards miniaturized strontium optical lattice clock

Wei He

Optical atomic clocks with precisions and accuracies in the \n10\\(^-\\)\\(^1\\)\\(^8\\) level [1] are now the most advanced man-made timekeeping devices. They outperform the microwave cesium atomic clocks that realize the SI definition of the second. Scaling down the size of optical atomic clocks may open the door to a range of industrial and space applications. \n \nIn this thesis, the design and preliminary results of a compact strontium cooling system are presented. In the first cooling stage, the high power 461 nm laser with 300 mW output features a modular design, while smaller laser sources for demonstrating a strontium magneto-optical trap have also been investigated. An innovative design that couples a spectroscopy cell directly into the scientific chamber reduces the overall size and power consumption of the system. Additionally, using strontium oxide as a source of strontium atoms suitable for optical clocks has achieved initial success. For the first time, a single-beam MOT configuration is applied to strontium. In this novel apparatus, the blue MOT and red MOT broadband cooling phases are able to trap 5x10\\(^6\\) and 1000 atoms, respectively. This work shows promising progress towards developing a functional miniaturized strontium optical lattice clock.

•Jul 1, 2017•5 citations

Magneto-optical trapping of strontium for use as a mobile frequency reference

Bjorn Ole Kock

Atomic Caesium clocks have made an astonishing development in the past few decades, with them gaining an order of magnitude in precision every decade. A new generation of atomic optical clocks is now emerging, which is moving to the forefront of timekeeping. By going from microwave to optical frequencies these clocks are now reaching fractional uncertainty levels in the 10\\(^-\\)\\(^1\\)\\(^8\\), opening a whole new range of exciting applications. This thesis presents the design and implementation of an experiment for laser cooling of strontium atoms, focusing on the mobility of the setup, opening a range of new applications as a mobile clock. The experimental apparatus applies a range of new techniques for strontium, such as the use of a two dimensional magneto-optical trap for pre cooling atoms, allowing for a compact and transportable system. A mobile laser system for laser cooling strontium atoms was realized. This includes a frequency doubling system for the main cooling transition. The constructed monolithic frequency doubling cavity has generated 300 mW of blue light and proven to be a stable setup suitable for a mobile system. The 3D-MOT was able to capture 4 * 10\\(^5\\) atoms with a long lifetime of 5.5 s, with further improvements for a significant increase in atom number currently being implemented.

•Dec 1, 2013•6 citations

Development of an Apparatus for a Strontium Optical Lattice Optical Frequency Standard

Ian R. Hill

Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.

•Jun 1, 2012•3 citations

DEVELOPMENT OF AN OPTICAL CLOCK BASED ON NEUTRAL STRONTIUM ATOMS HELD IN A LATTICE TRAP

E. A. Curtis, Yuri B. Ovchinnikov, Ian R. Hill +2 more

At the National Physical Laboratory we are developing a neutral atom optical clock based on strontium atoms held in an optical lattice during the clock frequency measurement. The innovation of lattice-type clocks has greatly reduced velocity-related systematic frequency shifts compared to ballistic expansion neutral atom clocks. However, with predicted fractional uncertainties as low as 10 -18 , many previously unexplored systematic effects become relevant, especially in dealing with shifts due to blackbody radiation. We are designing a compact, diode-laser-based system, with a view to future transportable systems, and which includes a novel permanent-magnet-based Zeeman slower and a blackbody measurement chamber.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Prospect for a compact strontium optical lattice clock

N. Poli, Robert E. Drullinger, G. Ferrari +4 more

We report on our progress toward the realization of a compact optical frequency standard referenced to strontium intercombination lines. Our current setup allows the production of ultracold Sr atoms in hundreds of ms. For high resolution spectroscopy of the 1S0-3P0 doubly forbidden transition we have prepared a 698 nm clock laser stabilized on a high finesse, symmetrically suspended cavity and a high power 813 nm light source for the optical lattice trap at the magic wavelength. Due to their compactness, reliability, and low power consumption, semiconductor laser sources represent the best choice for the development of compact and transportable devices for application both on Earth and in Space. A new Sr trapping and cooling experimental setup is also presented.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•9 citations

Progress towards a strontium optical lattice clock at NPL

Elizabeth M. Bridge, Ian R. Hill, Yuri B. Ovchinnikov +3 more

The1S0-3P0transition at 698 nm in neutral strontium has the potential to be an extremely precise optical frequency standard [1] and is one of several candidates for a future redefinition of the second. Recent measurements of this transition at three national laboratories around the world have fractional frequency uncertainties in the 1015range and agree to within a hertz [2,3,4]. To realise fully the potential accuracy of this frequency standard, in depth studies of systematic effects need to be performed in order to characterise them at the level necessary for a redefinition of the second. At the National Physical Laboratory we are developing a compact, diode laser based optical lattice clock. We intend to study the clock transition in both88Sr and87Sr with focus on the uncertainties in the frequency shifts due to blackbody radiation. The setup incorporates a novel permanent magnet based Zeeman slower [5].

European Frequency and Time Forum•Apr 1, 2010•0 citations
Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.
Optical atomic clocks with precisions and accuracies in the \n10\\(^-\\)\\(^1\\)\\(^8\\) level [1] are now the most advanced man-made timekeeping devices. They outperform the microwave cesium atomic clocks that realize the SI definition of the second. Scaling down the size of optical atomic clocks may open the door to a range of industrial and space applications. \n \nIn this thesis, the design and preliminary results of a compact strontium cooling system are presented. In the first cooling stage, the high power 461 nm laser with 300 mW output features a modular design, while smaller laser sources for demonstrating a strontium magneto-optical trap have also been investigated. An innovative design that couples a spectroscopy cell directly into the scientific chamber reduces the overall size and power consumption of the system. Additionally, using strontium oxide as a source of strontium atoms suitable for optical clocks has achieved initial success. For the first time, a single-beam MOT configuration is applied to strontium. In this novel apparatus, the blue MOT and red MOT broadband cooling phases are able to trap 5x10\\(^6\\) and 1000 atoms, respectively. This work shows promising progress towards developing a functional miniaturized strontium optical lattice clock.
Atomic Caesium clocks have made an astonishing development in the past few decades, with them gaining an order of magnitude in precision every decade. A new generation of atomic optical clocks is now emerging, which is moving to the forefront of timekeeping. By going from microwave to optical frequencies these clocks are now reaching fractional uncertainty levels in the 10\\(^-\\)\\(^1\\)\\(^8\\), opening a whole new range of exciting applications. This thesis presents the design and implementation of an experiment for laser cooling of strontium atoms, focusing on the mobility of the setup, opening a range of new applications as a mobile clock. The experimental apparatus applies a range of new techniques for strontium, such as the use of a two dimensional magneto-optical trap for pre cooling atoms, allowing for a compact and transportable system. A mobile laser system for laser cooling strontium atoms was realized. This includes a frequency doubling system for the main cooling transition. The constructed monolithic frequency doubling cavity has generated 300 mW of blue light and proven to be a stable setup suitable for a mobile system. The 3D-MOT was able to capture 4 * 10\\(^5\\) atoms with a long lifetime of 5.5 s, with further improvements for a significant increase in atom number currently being implemented.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.
At the National Physical Laboratory we are developing a neutral atom optical clock based on strontium atoms held in an optical lattice during the clock frequency measurement. The innovation of lattice-type clocks has greatly reduced velocity-related systematic frequency shifts compared to ballistic expansion neutral atom clocks. However, with predicted fractional uncertainties as low as 10 -18 , many previously unexplored systematic effects become relevant, especially in dealing with shifts due to blackbody radiation. We are designing a compact, diode-laser-based system, with a view to future transportable systems, and which includes a novel permanent-magnet-based Zeeman slower and a blackbody measurement chamber.
We report on our progress toward the realization of a compact optical frequency standard referenced to strontium intercombination lines. Our current setup allows the production of ultracold Sr atoms in hundreds of ms. For high resolution spectroscopy of the 1S0-3P0 doubly forbidden transition we have prepared a 698 nm clock laser stabilized on a high finesse, symmetrically suspended cavity and a high power 813 nm light source for the optical lattice trap at the magic wavelength. Due to their compactness, reliability, and low power consumption, semiconductor laser sources represent the best choice for the development of compact and transportable devices for application both on Earth and in Space. A new Sr trapping and cooling experimental setup is also presented.
The1S0-3P0transition at 698 nm in neutral strontium has the potential to be an extremely precise optical frequency standard [1] and is one of several candidates for a future redefinition of the second. Recent measurements of this transition at three national laboratories around the world have fractional frequency uncertainties in the 1015range and agree to within a hertz [2,3,4]. To realise fully the potential accuracy of this frequency standard, in depth studies of systematic effects need to be performed in order to characterise them at the level necessary for a redefinition of the second. At the National Physical Laboratory we are developing a compact, diode laser based optical lattice clock. We intend to study the clock transition in both88Sr and87Sr with focus on the uncertainties in the frequency shifts due to blackbody radiation. The setup incorporates a novel permanent magnet based Zeeman slower [5].