Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

URSI Asia-Pacific Radio Science Conference

The Development of the NIM-Yb1 Ion Optical Clock

Shaoyang Dai, Yani Zuo, Chaowei Wang, Shiying Cao, Kun Liu, Weiliang Chen, Fasong Zhen, Wenbo Zhao, Fang Fang

Published Jan 1, 2025• 1 citation
Publisher

Abstract

Optical clocks serve as the benchmark devices for the next-generation definition of the second and have significant applications in testing the theories beyong the standard models, dark matter research, and related fields.The ytterbium ion optical clock, featuring two clock transition lines, is among the most precise optical clocks with the lowest uncertainties.The National Institute of Metrology, China (NIM), initiated research on ytterbium ion optical clocks in 2021.Based on an end-cap ion trap, a vacuum system has been established.A 370 nm thirdharmonic fiber laser, along with 760 nm and 935 nm DFB lasers, ensures a stable operation of the optical system.To date, both the electric quadrupole and electric octupole clock transitions have been observed.A 2.8 Hz linewidth of the electric octupole transition has been achieved, with a stability of 1.7E-15 τ -1/2 after closed-loop locking.The uncertainties due to AC Starks shift from clock laser and second-order Doppler shifts are being evaluated, with an expected total uncertainty below 5E-18.

DOI
10.46620/ursiaprasc25/wugq6568

Related papers

Towards a High-Performance Optical Clock Based on Single 171-Yb Ion

Yani Zuo, Shaoyang Dai, Shiying Cao +5 more

With the development of optical frequency comb and ultra-stable laser techniques, the performance of optical frequency standards has been improved significantly over the past decades. Single charged Yb ions have an alkali-like atomic structure and have ultra-long storage time. And the ytterbium single-ion optical frequency standards have two clock transitions (E2 & E3). In this paper, we will introduce the progress in the development of a highly accurate optical frequency standard based on single ytterbium-171 ion at the National Institute of Metrology (NIM), China.

IEEE Optoelectronics Global Conference (OGC)•Sep 15, 2021•2 citations

Progress toward a single ytterbium ion optical clock

Paul Taylor, Stephen A. Webster, Matthew Roberts +3 more

Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•0 citations

An Yb optical lattice clock: Current status at KRISS

Dai-Hyuk Yu, Chang Yong Park, Won-Kyu Lee +5 more

The current status of an Yb optical lattice clock at the Korea Research Institute of Standards and Science (KRISS) is reported. The systematic uncertainty of the Yb clock in the first accuracy evaluation was 1.5 × 10 −14 [Park et al. , Metrologia 50, 119 (2013)]. The uncertainty was dominated by the large uncertainties in the lattice ac Stark shift and the collisional shift, which were mainly limited by the large linewidth and jitter of the clock laser. Recently, a highly stable clock laser at 578 nm was developed with a short-term linewidth of 3.5 Hz and a frequency jitter of about 25 Hz at 1 s and 10 s measurement times, respectively. The long-term frequency drift showed only a linear dependence on time, confirming that the temperature of the super-cavity was maintained a zero coefficient of thermal expansion. The frequency of the lattice laser at 759 nm was phase locked to the optical frequency comb and could be stabilized at the “absolute” frequency of the “magic wavelength”, to within a 1-MHz uncertainty. This improvement greatly reduced the fractional uncertainty due to the lattice ac Stark shift down to 2 × 10 −16 . The systematic uncertainty of the clock is currently 5.3 × 10 −15 and is dominated by the collisional frequency shift.

Journal of the Korean Physical Society•Aug 1, 2013•12 citations

Yb+ single-ion optical frequency standard with systematic uncertainty at the 10−17 level

Nils Huntemann, B. Lipphardt, Maksim V. Okhapkin +2 more

The171Yb+ion possesses two transitions that are applicable as references for optical frequency standards and several general features make this ion attractive: All relevant radiations for cooling and excitation can be generated from diode lasers. A nuclear spin of 1/2 ensures a simple sublevel structure. Long storage times of Yb+in ion traps are easily obtained. The2S1/2(F = 0) →2D3/2(F = 2, mF= 0) electric quadrupole transition at 436 nm with a natural linewidth of 3.1 Hz provides a quantum noise limited instability of a single-ion frequency standard of about 2 × 10-15in 1 s. The electric octupole transition2S1/2(F = 0)→2F7/2(F = 3, mF= 0) at 467 nm with a natural linewidth in the nHz range will allow to surpass that instability level. It also possesses a lower sensitivity to field-induced frequency shifts. In this system the Fourier-limited interrogation linewidth can be adapted to that of the best available laser sources, which are presently at the level below 1 Hz. Both transitions have been recommended as secondary representations of the SI second.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2013•0 citations

A TRAPPED 171 Yb + ION OPTICAL FREQUENCY STANDARD BASED ON THE S 1/2 - F 7/2 TRANSITION

P. GILL, Stephen A. Webster, G. HUANG +7 more

The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Optical Ion Clock with Engineered Immunity to Motion-Induced Frequency Shifts — E8 Intelligence Research

Andrew Stewart Caldin

Spectroscopic frequency shifts due to residual motion of the probed atoms significantly contribute to the uncertainty budgets of state-of-the-art optical ion clocks. For clock transitions with second-order Doppler and quadratic Stark shifts of opposite signs, it is possible to configure electrodynamic ion confinement such that these two shift effects become anticorrelated causing zero net shift. Here, we introduce a spectroscopic interrogation protocol which leads, for systems with unknown and varying motional energy gain rates, to first-order auto-suppression of corresponding frequency shifts without requiring the opposite-sign configuration. We experimentally demonstrate the proposed method on a new ytterbium ion optical clock probing the 467 nm electric octupole (E3) transition, where the combined fractional uncertainty contribution from motion-induced frequency shifts is reduced from $1.3\times10^{-18}$ to $0.3\times10^{-18}$. An interleaved optical frequency ratio measurement agai Author: Andrew Stewart Caldin, Independent Researcher, UK. Part of the E8 Intelligence Research series. Platform: e8intelligence.com

•Nov 10, 2026•0 citations
Optical clocks serve as the benchmark devices for the next-generation definition of the second and have significant applications in testing the theories beyong the standard models, dark matter research, and related fields.The ytterbium ion optical clock, featuring two clock transition lines, is among the most precise optical clocks with the lowest uncertainties.The National Institute of Metrology, China (NIM), initiated research on ytterbium ion optical clocks in 2021.Based on an end-cap ion trap, a vacuum system has been established.A 370 nm thirdharmonic fiber laser, along with 760 nm and 935 nm DFB lasers, ensures a stable operation of the optical system.To date, both the electric quadrupole and electric octupole clock transitions have been observed.A 2.8 Hz linewidth of the electric octupole transition has been achieved, with a stability of 1.7E-15 τ -1/2 after closed-loop locking.The uncertainties due to AC Starks shift from clock laser and second-order Doppler shifts are being evaluated, with an expected total uncertainty below 5E-18.
With the development of optical frequency comb and ultra-stable laser techniques, the performance of optical frequency standards has been improved significantly over the past decades. Single charged Yb ions have an alkali-like atomic structure and have ultra-long storage time. And the ytterbium single-ion optical frequency standards have two clock transitions (E2 & E3). In this paper, we will introduce the progress in the development of a highly accurate optical frequency standard based on single ytterbium-171 ion at the National Institute of Metrology (NIM), China.
Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.
The current status of an Yb optical lattice clock at the Korea Research Institute of Standards and Science (KRISS) is reported. The systematic uncertainty of the Yb clock in the first accuracy evaluation was 1.5 × 10 −14 [Park et al. , Metrologia 50, 119 (2013)]. The uncertainty was dominated by the large uncertainties in the lattice ac Stark shift and the collisional shift, which were mainly limited by the large linewidth and jitter of the clock laser. Recently, a highly stable clock laser at 578 nm was developed with a short-term linewidth of 3.5 Hz and a frequency jitter of about 25 Hz at 1 s and 10 s measurement times, respectively. The long-term frequency drift showed only a linear dependence on time, confirming that the temperature of the super-cavity was maintained a zero coefficient of thermal expansion. The frequency of the lattice laser at 759 nm was phase locked to the optical frequency comb and could be stabilized at the “absolute” frequency of the “magic wavelength”, to within a 1-MHz uncertainty. This improvement greatly reduced the fractional uncertainty due to the lattice ac Stark shift down to 2 × 10 −16 . The systematic uncertainty of the clock is currently 5.3 × 10 −15 and is dominated by the collisional frequency shift.
The171Yb+ion possesses two transitions that are applicable as references for optical frequency standards and several general features make this ion attractive: All relevant radiations for cooling and excitation can be generated from diode lasers. A nuclear spin of 1/2 ensures a simple sublevel structure. Long storage times of Yb+in ion traps are easily obtained. The2S1/2(F = 0) →2D3/2(F = 2, mF= 0) electric quadrupole transition at 436 nm with a natural linewidth of 3.1 Hz provides a quantum noise limited instability of a single-ion frequency standard of about 2 × 10-15in 1 s. The electric octupole transition2S1/2(F = 0)→2F7/2(F = 3, mF= 0) at 467 nm with a natural linewidth in the nHz range will allow to surpass that instability level. It also possesses a lower sensitivity to field-induced frequency shifts. In this system the Fourier-limited interrogation linewidth can be adapted to that of the best available laser sources, which are presently at the level below 1 Hz. Both transitions have been recommended as secondary representations of the SI second.
The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.
Spectroscopic frequency shifts due to residual motion of the probed atoms significantly contribute to the uncertainty budgets of state-of-the-art optical ion clocks. For clock transitions with second-order Doppler and quadratic Stark shifts of opposite signs, it is possible to configure electrodynamic ion confinement such that these two shift effects become anticorrelated causing zero net shift. Here, we introduce a spectroscopic interrogation protocol which leads, for systems with unknown and varying motional energy gain rates, to first-order auto-suppression of corresponding frequency shifts without requiring the opposite-sign configuration. We experimentally demonstrate the proposed method on a new ytterbium ion optical clock probing the 467 nm electric octupole (E3) transition, where the combined fractional uncertainty contribution from motion-induced frequency shifts is reduced from 1.3×10−181.3\times10^{-18}1.3×10−18 to 0.3×10−180.3\times10^{-18}0.3×10−18. An interleaved optical frequency ratio measurement agai Author: Andrew Stewart Caldin, Independent Researcher, UK. Part of the E8 Intelligence Research series. Platform: e8intelligence.com