Wiley eBooks

Analyses of the “Series Feedback Coil (Circuit)” ( SFC )

Yi Zhang, Hui Dong, Hans‐Joachim Krause, Guofeng Zhang, Xiaoming Xie

Published May 29, 2020• 0 citations
Publisher

Abstract

This chapter thoroughly analyzes the effects of Series Feedback Coil (Circuit) (SFC). In current bias mode, the chapter begins with a model of “two voltages in series” to understand the principle of the SFC. In voltage bias mode, the SFC increases the apparent flux-to-current transfer coefficient of a Superconducting QUantum Interference Device (SQUID), thus reducing noise contribution of the preamplifier. For both bias modes, the SFC reduces the apparent dynamic resistance. In current bias mode, the readout quantity is the voltage signal of the SQUID. In practice, the choice between parallel feedback circuit (PFC) and SFC depends not only on the preamplifier but also on the SQUID parameters. The combination of PFC and SFC in voltage bias mode can be abbreviated as PSFC, which was also called SQUID bootstrap circuit. The chapter demonstrates the PSFC in voltage bias mode and observes different behavior of PSFC at different working points.

DOI
10.1002/9783527816514.ch9

Related papers

Flux Feedback Concepts and Parallel Feedback Circuit

Yi Zhang, Hui Dong, Hans‐Joachim Krause +2 more

This chapter highlights the direct readout scheme with feedback circuits in the “head stage” at cryogenic temperature. Generally, there are two typical kinds of feedback circuits, i.e. the parallel feedback circuit (PFC) and series feedback coil (circuit) (SFC). In a sense, the modified SQUID's “head stage” with PFC (or SFC) can be regarded as a new device with apparent parameters. The chapter discusses the apparent parameters of the SQUID with PFC, e.g. the change in the SQUID's transfer coefficient at the working point. It qualitatively analyzes the PFC in current bias mode, namely, the additional positive feedback scheme. The chapter also focuses on the flux noise contribution of the preamplifier and discusses the flux noise contribution from the Johnson voltage noise. Indeed, for a stable low-noise SQUID readout technique, operating a SQUID with a PFC in range, or possibly in the transition range is recommended.

Wiley eBooks•May 29, 2020•0 citations

An approach to optimization of the superconducting quantum interference device bootstrap circuit

Guofeng Zhang, Yi Zhang, Hui Dong +5 more

Recently, we demonstrated and analysed the superconducting quantum interference device (SQUID) bootstrap circuit (SBC). It is a direct readout scheme for dc SQUID in the voltage bias mode, permitting one to suppress the preamplifier noise. The SBC enables us to control the two key parameters of a voltage-biased SQUID: the flux-to-current transfer coefficient and the dynamic resistance. The flux-to-current, I-Phi, characteristics of SBC are made asymmetric by introducing the additional current feedback. Depending upon the choice of the working point, this feedback can be positive (working point W-2 on the steeper I-Phi slope) or negative (W-1 on the less steep slope). The dynamic resistance is controlled by the additional voltage feedback. In our publications to date we presented only the SBC operation at W-2, while in this paper we demonstrate operation at W-1 and show that also in this regime the preamplifier noise suppression is possible. We used a liquid-helium-cooled Nb SQUID with a loop inductance of 350 pH and attained white flux noise of 2.5 mu Phi(0) Hz(-1/2) both at W-2 and at W-1. In the latter case, the linear flux range exceeded one half-flux quantum Phi(0). This large linear range should lead to a significantly improved stability and slew rate of the system and also make the tolerable spread in circuit parameters much wider than in all SQUID direct readout schemes known to date. Consequently, operation in this regime opens a new path to possible SBC optimization.

Superconductor Science and Technology•Apr 21, 2011•11 citations

An insight into voltage-biased superconducting quantum interference devices

Chao Liu, Yi Zhang, Michael Mück +5 more

We experimentally studied two important parameters of helium-cooled superconducting quantum interference devices (SQUIDs) in the voltage bias mode: the dynamic resistance Rd and the flux-to-current transfer coefficient ∂i/∂Φ, with different junction shunt resistors RJ. We investigated a voltage-biased SQUID using the direct readout current-to-voltage converter scheme involving an operational amplifier. At higher RJ, the flux-to-voltage conversion coefficient ∂V/∂Φ becomes sufficiently large to effectively suppress the room-temperature amplifier's noise without any need for additional feedback circuits. The McCumber parameter limits the rise of ∂V/∂Φ. We discuss the performance of voltage-biased SQUIDs at different effective McCumber parameters.

Applied Physics Letters•Nov 26, 2012•20 citations

Flux Modulation Scheme ( FMS )

Yi Zhang, Hui Dong, Hans-Joachim Krause +2 more

This chapter introduces the “mixed bias mode” and discusses the flux modulation scheme (FMS). It revisits the FMS by analyzing the bias mode and the transfer characteristics of a step-up transformer. The readout schemes share the common idea of modifying the Superconducting QUantum Interference Device (SQUID) input circuit to enhance the SQUID's apparent transfer coefficient at the input terminals of the preamplifier. The SQUID is matched to a preamplifier via a four-terminal step-up transformer. The “head stage” of the FMS is essentially an AC circuit and is calibrated by the amplitude- and phase-to-frequency transfer characteristics of the transformer. The two imperfections for SQUID operation in FMS, one is the shunt effect of primary winding and the other is nonlinear transformation from primary winding to secondary winding, to reduce benefit of the transformer.

Wiley eBooks•May 29, 2020•0 citations

Superconducting quantum interference device readout circuit with tunable feedback polarity

Xinyu Wu, Jianshe Liu, Wei Chen

Feedback circuits, which act as functional units in superconducting quantum interference device (SQUID) readout circuits, such as positive feedback circuits for suppressing the preamplifier noise contribution or negative feedback circuits for increasing the linear flux range of SQUID, enable SQUIDs to achieve high performance in practical applications. Integrating feedback circuits with different functions into a single SQUID chip contributes to the construction of highly compact SQUID electronics. Here, we propose a SQUID readout circuit with tunable feedback polarity (TFP). The switching of the feedback polarity is easily realized by applying a control current to the superconducting switches integrated into the SQUID chip. The enhancement of the flux-to-voltage transfer coefficient or the linear flux range depends on the choice of feedback polarity. In addition, we introduce a two-stage scheme to address the degraded noise performance induced by negative feedback. This work attempts to develop a compact and versatile architecture of SQUID readout by using a set of compatible superconducting technologies.

Review of Scientific Instruments•Sep 1, 2023•1 citation

Bias Reversal Technique in SQUID Bootstrap Circuit (SBC) Scheme

Liangliang Rong, Yi Zhang, Guofeng Zhang +5 more

Recently, a SQUID direct readout scheme called voltage-biased SQUID Bootstrap Circuit (SBC) is introduced to reduce preamplifier noise contribution. In this paper, we describe a concept of SBC with bias reversal technique which can suppress SQUID intrinsic 1/f noise. When applying a symmetrically rectangular voltage across SBC, two I-Φ characteristics appear at the amplifier output. In order to return to one I - Φ curve, a demodulation technique is required. Because of the asymmetry of typical SBC I-Φ curve, the demodulation method is realized by using a flux compensation of one half Φ0 flux shift. The output signal is then filtered and returned to one I-Φ curve for ordinary FLL readout. It was found, the reversal frequency fR can be dramatically enhanced when using a preamplifier consisting of two operational amplifiers. A planar Nb SQUID magnetometer with a loop-inductance of 350 pH, fR =50 kHz and a second order low pass filter with 10 kHz cut off frequency was employed in our experiment. Results prove the feasibility of SBC bias reversal method. Comparative experiment on noise performance will be carried out in further studies.

Physics Procedia•Jan 1, 2012•1 citation
This chapter thoroughly analyzes the effects of Series Feedback Coil (Circuit) (SFC). In current bias mode, the chapter begins with a model of “two voltages in series” to understand the principle of the SFC. In voltage bias mode, the SFC increases the apparent flux-to-current transfer coefficient of a Superconducting QUantum Interference Device (SQUID), thus reducing noise contribution of the preamplifier. For both bias modes, the SFC reduces the apparent dynamic resistance. In current bias mode, the readout quantity is the voltage signal of the SQUID. In practice, the choice between parallel feedback circuit (PFC) and SFC depends not only on the preamplifier but also on the SQUID parameters. The combination of PFC and SFC in voltage bias mode can be abbreviated as PSFC, which was also called SQUID bootstrap circuit. The chapter demonstrates the PSFC in voltage bias mode and observes different behavior of PSFC at different working points.
This chapter highlights the direct readout scheme with feedback circuits in the “head stage” at cryogenic temperature. Generally, there are two typical kinds of feedback circuits, i.e. the parallel feedback circuit (PFC) and series feedback coil (circuit) (SFC). In a sense, the modified SQUID's “head stage” with PFC (or SFC) can be regarded as a new device with apparent parameters. The chapter discusses the apparent parameters of the SQUID with PFC, e.g. the change in the SQUID's transfer coefficient at the working point. It qualitatively analyzes the PFC in current bias mode, namely, the additional positive feedback scheme. The chapter also focuses on the flux noise contribution of the preamplifier and discusses the flux noise contribution from the Johnson voltage noise. Indeed, for a stable low-noise SQUID readout technique, operating a SQUID with a PFC in range, or possibly in the transition range is recommended.
Recently, we demonstrated and analysed the superconducting quantum interference device (SQUID) bootstrap circuit (SBC). It is a direct readout scheme for dc SQUID in the voltage bias mode, permitting one to suppress the preamplifier noise. The SBC enables us to control the two key parameters of a voltage-biased SQUID: the flux-to-current transfer coefficient and the dynamic resistance. The flux-to-current, I-Phi, characteristics of SBC are made asymmetric by introducing the additional current feedback. Depending upon the choice of the working point, this feedback can be positive (working point W-2 on the steeper I-Phi slope) or negative (W-1 on the less steep slope). The dynamic resistance is controlled by the additional voltage feedback. In our publications to date we presented only the SBC operation at W-2, while in this paper we demonstrate operation at W-1 and show that also in this regime the preamplifier noise suppression is possible. We used a liquid-helium-cooled Nb SQUID with a loop inductance of 350 pH and attained white flux noise of 2.5 mu Phi(0) Hz(-1/2) both at W-2 and at W-1. In the latter case, the linear flux range exceeded one half-flux quantum Phi(0). This large linear range should lead to a significantly improved stability and slew rate of the system and also make the tolerable spread in circuit parameters much wider than in all SQUID direct readout schemes known to date. Consequently, operation in this regime opens a new path to possible SBC optimization.
We experimentally studied two important parameters of helium-cooled superconducting quantum interference devices (SQUIDs) in the voltage bias mode: the dynamic resistance Rd and the flux-to-current transfer coefficient ∂i/∂Φ, with different junction shunt resistors RJ. We investigated a voltage-biased SQUID using the direct readout current-to-voltage converter scheme involving an operational amplifier. At higher RJ, the flux-to-voltage conversion coefficient ∂V/∂Φ becomes sufficiently large to effectively suppress the room-temperature amplifier's noise without any need for additional feedback circuits. The McCumber parameter limits the rise of ∂V/∂Φ. We discuss the performance of voltage-biased SQUIDs at different effective McCumber parameters.
This chapter introduces the “mixed bias mode” and discusses the flux modulation scheme (FMS). It revisits the FMS by analyzing the bias mode and the transfer characteristics of a step-up transformer. The readout schemes share the common idea of modifying the Superconducting QUantum Interference Device (SQUID) input circuit to enhance the SQUID's apparent transfer coefficient at the input terminals of the preamplifier. The SQUID is matched to a preamplifier via a four-terminal step-up transformer. The “head stage” of the FMS is essentially an AC circuit and is calibrated by the amplitude- and phase-to-frequency transfer characteristics of the transformer. The two imperfections for SQUID operation in FMS, one is the shunt effect of primary winding and the other is nonlinear transformation from primary winding to secondary winding, to reduce benefit of the transformer.
Feedback circuits, which act as functional units in superconducting quantum interference device (SQUID) readout circuits, such as positive feedback circuits for suppressing the preamplifier noise contribution or negative feedback circuits for increasing the linear flux range of SQUID, enable SQUIDs to achieve high performance in practical applications. Integrating feedback circuits with different functions into a single SQUID chip contributes to the construction of highly compact SQUID electronics. Here, we propose a SQUID readout circuit with tunable feedback polarity (TFP). The switching of the feedback polarity is easily realized by applying a control current to the superconducting switches integrated into the SQUID chip. The enhancement of the flux-to-voltage transfer coefficient or the linear flux range depends on the choice of feedback polarity. In addition, we introduce a two-stage scheme to address the degraded noise performance induced by negative feedback. This work attempts to develop a compact and versatile architecture of SQUID readout by using a set of compatible superconducting technologies.
Recently, a SQUID direct readout scheme called voltage-biased SQUID Bootstrap Circuit (SBC) is introduced to reduce preamplifier noise contribution. In this paper, we describe a concept of SBC with bias reversal technique which can suppress SQUID intrinsic 1/f noise. When applying a symmetrically rectangular voltage across SBC, two I-Φ characteristics appear at the amplifier output. In order to return to one I - Φ curve, a demodulation technique is required. Because of the asymmetry of typical SBC I-Φ curve, the demodulation method is realized by using a flux compensation of one half Φ0 flux shift. The output signal is then filtered and returned to one I-Φ curve for ordinary FLL readout. It was found, the reversal frequency fR can be dramatically enhanced when using a preamplifier consisting of two operational amplifiers. A planar Nb SQUID magnetometer with a loop-inductance of 350 pH, fR =50 kHz and a second order low pass filter with 10 kHz cut off frequency was employed in our experiment. Results prove the feasibility of SBC bias reversal method. Comparative experiment on noise performance will be carried out in further studies.