Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Published Jan 1, 2017• 0 citations
OpenAlex

Abstract

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

Related papers

Approaching Quantum-Limited Metrology with Imperfect Detectors by Using Weak-Value Amplification

Liang Xu, Zexuan Liu, Animesh Datta +4 more

Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.

arXiv:2005.03629•Physical Review Letters•Aug 17, 2020•98 citations

Achieving metrological precision limits through postselection

G. B. Alves, Arthur Pimentel, Malena O. Hor-Meyll +3 more

Postselection strategies have been proposed with the aim of amplifying weak signals, which may help to overcome detection thresholds associated with technical noise in high-precision measurements. Here we use an optical setup to experimentally explore two different postselection protocols for the estimation of a small parameter: a weak-value amplification procedure and an alternative method that does not provide amplification but nonetheless is shown to be more robust for the sake of parameter estimation. Each technique leads approximately to the saturation of quantum limits for the estimation precision, expressed by the Cram\'er-Rao bound. For both situations, we show that parameter estimation is improved when the postselection statistics are considered together with the measurement device.

arXiv:1606.03478•Physical Review A•Jan 6, 2017•16 citations

Weak values considered harmful

Christopher Ferrie, Joshua Combes

We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

•Jul 15, 2013•4 citations

Practical advantages of almost-balanced-weak-value metrological techniques

Julián Martínez-Rincón, Zekai Chen, John C. Howell

Precision measurements of ultrasmall linear velocities of one of the mirrors in a Michelson interferometer are performed using two different weak-value techniques. We show that the technique of almost-balanced weak values (ABWV) offers practical advantages over the technique of weak-value amplification, resulting in larger signal-to-noise ratios and the possibility of longer integration times due to robustness to slow drifts. As an example of the performance of the ABWV protocol we report a velocity sensitivity of 60 fm/s after 40 h of integration time. The sensitivity of the Doppler shift due to the moving mirror is 150 nHz.

arXiv:1703.01632•Physical Review A•Jun 5, 2017•18 citations

Fisher information analysis on weak-value-amplification metrology using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.

arXiv:2201.13016•Physical Review A•Aug 30, 2022•21 citations

Autocorrelative weak-value amplification and simulating the protocol under strong Gaussian noise

Jing-Hui Huang, Xiangyun Hu, Adetunmise C. Dada +4 more

By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.

arXiv:2203.15231•Physical Review A•Nov 3, 2022•9 citations
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.
Postselection strategies have been proposed with the aim of amplifying weak signals, which may help to overcome detection thresholds associated with technical noise in high-precision measurements. Here we use an optical setup to experimentally explore two different postselection protocols for the estimation of a small parameter: a weak-value amplification procedure and an alternative method that does not provide amplification but nonetheless is shown to be more robust for the sake of parameter estimation. Each technique leads approximately to the saturation of quantum limits for the estimation precision, expressed by the Cram\'er-Rao bound. For both situations, we show that parameter estimation is improved when the postselection statistics are considered together with the measurement device.
We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.
Precision measurements of ultrasmall linear velocities of one of the mirrors in a Michelson interferometer are performed using two different weak-value techniques. We show that the technique of almost-balanced weak values (ABWV) offers practical advantages over the technique of weak-value amplification, resulting in larger signal-to-noise ratios and the possibility of longer integration times due to robustness to slow drifts. As an example of the performance of the ABWV protocol we report a velocity sensitivity of 60 fm/s after 40 h of integration time. The sensitivity of the Doppler shift due to the moving mirror is 150 nHz.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.