Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2005.03629 · Physical Review Letters

Approaching Quantum-Limited Metrology with Imperfect Detectors by Using Weak-Value Amplification

Liang Xu, Zexuan Liu, Animesh Datta, George C. Knee, Jeff S. Lundeen, Yanqing Lu, Lijian Zhang

Published Aug 17, 2020• 98 citations
arXivHTMLPDF

Abstract

Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.

DOI
10.1103/physrevlett.125.080501

Related papers

Heisenberg-Limited Metrology via Weak-Value Amplification without Using Entangled Resources

Yosep Kim, Seung-Yeun Yoo, Yoon-Ho Kim

Weak-value amplification (WVA) provides a way for amplified detection of a tiny physical signal at the expense of a lower detection probability. Despite this trade-off, due to its robustness against certain types of noise, WVA has advantages over conventional measurements in precision metrology. Moreover, it has been shown that WVA-based metrology can reach the Heisenberg limit using entangled resources, but preparing macroscopic entangled resources remains challenging. Here, we demonstrate a novel WVA scheme based on iterative interactions, achieving the Heisenberg-limited precision scaling without resorting to entanglement. This indicates that the perceived advantages of the entanglement-assisted WVA are in fact due to iterative interactions between each particle of an entangled system and a meter, rather than coming from the entanglement itself. Our work opens a practical pathway for achieving the Heisenberg-limited WVA without using fragile and experimentally demanding entangled resources.

arXiv:2109.03762•Physical Review Letters•Jan 25, 2022•38 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•13 citations

Weak-Value Amplification for Longitudinal Phase Measurements Approaching the Shot-Noise Limit Characterized by Allan Variance

Jing-Hui Huang, Xiang-Yun Hu

We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of $T$ = $0.01-0.1$ s, representing two orders of magnitude variance reduction compared to the $T=300$ s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number $1/N_r$, confirming shot-noise-limited operation with WVA. Furthermore, this $1/N_r$ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime ($>10$ Hz).

quant-pharXiv:2602.17035•Physical Review A•Feb 20, 2026•2 citations

Mitigating source and detection noises in autocorrelative weak-value amplification

Xiangyun Hu, Jing-Hui Huang, Feifan He +2 more

Weak-value amplification (WVA), a postselection-based technique that amplifies weak physical signals by preparing nearly orthogonal pre- and postselected quantum states, is intrinsically limited by various kinds of technical noise, which distorts amplified weak values, especially when discarding photons in postselection. While prior work established the efficacy of autocorrelative weak-value amplification (AWVA) under Gaussian noise, practical implementations face challenges from band-limited laser-source noise and detection noise (including shot noise and electrical noise). Here, we demonstrate that the AWVA protocol robustly suppresses both laser-power fluctuations and detection noise. Numerical experiments in Simulink further reveal AWVA's dual advantage: under high-power conditions, the noise-reduction superiority of AWVA over WVA becomes in- creasingly pronounced as input laser power increases, whereas in detection-limited regimes AWVA achieves an order-of-magnitude lower uncertainty, closely approaching the Cram\'er-Rao bound. Crucially, this work demonstrates that AWVA improves precision in both high-power (laser-noise-dominated) and photon-starved (detector-noise-dominated) regimes, thereby bridging these operating extremes and advancing precision in applications from gravitational-wave detection to hybrid quantum systems.

arXiv:2209.12732•Physical Review A•Oct 2, 2025•1 citation

Roadmap on Weak Measurements in Optics

Ritwik Dhara, Niladri Modak, Shyamal Guchhait +1 more

Abstract Even though weak measurements and weak value amplification (WVA) are founded on the principles of quantum mechanics and quantum measurements, these have found widespread applications in optics due to their inherent origin in wave interference. Besides their use in addressing foundational questions of quantum mechanics or for resolving quantum paradoxes, weak measurements and WVA have thus been used for numerous metrological applications, e.g., quantification of small optical beam displacement, tiny angular rotation, determination of extremely small phase shifts, spectral shifts, unraveling weak fundamental optical effects, improved optical imaging, amplifying weak signal and extracting small physical parameters and so forth. In this review, after providing the mathematical foundation of weak measurement and WVA, some of the metrological applications of weak measurements in the classical optics domain are briefly summarized, and the controversies and debates on the potential advantages of WVA in the estimation and detection of weak signal are discussed, and the interferometric philosophy of WVA is elucidated. The experimental weak measurement and WVA schemes in the domain of quantum optics are also discussed and highlighted the new perspectives and emerging trends of weak measurements in both the classical and quantum optics domain and their prospects in the development of next‐generation ultra‐sensitive optical devices.

Advanced Physics Research•Dec 19, 2024•7 citations
Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.
Weak-value amplification (WVA) provides a way for amplified detection of a tiny physical signal at the expense of a lower detection probability. Despite this trade-off, due to its robustness against certain types of noise, WVA has advantages over conventional measurements in precision metrology. Moreover, it has been shown that WVA-based metrology can reach the Heisenberg limit using entangled resources, but preparing macroscopic entangled resources remains challenging. Here, we demonstrate a novel WVA scheme based on iterative interactions, achieving the Heisenberg-limited precision scaling without resorting to entanglement. This indicates that the perceived advantages of the entanglement-assisted WVA are in fact due to iterative interactions between each particle of an entangled system and a meter, rather than coming from the entanglement itself. Our work opens a practical pathway for achieving the Heisenberg-limited WVA without using fragile and experimentally demanding entangled resources.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of TTT = 0.01−0.10.01-0.10.01−0.1 s, representing two orders of magnitude variance reduction compared to the T=300T=300T=300 s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number 1/Nr1/N_r1/Nr​, confirming shot-noise-limited operation with WVA. Furthermore, this 1/Nr1/N_r1/Nr​ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime (>10>10>10 Hz).
Weak-value amplification (WVA), a postselection-based technique that amplifies weak physical signals by preparing nearly orthogonal pre- and postselected quantum states, is intrinsically limited by various kinds of technical noise, which distorts amplified weak values, especially when discarding photons in postselection. While prior work established the efficacy of autocorrelative weak-value amplification (AWVA) under Gaussian noise, practical implementations face challenges from band-limited laser-source noise and detection noise (including shot noise and electrical noise). Here, we demonstrate that the AWVA protocol robustly suppresses both laser-power fluctuations and detection noise. Numerical experiments in Simulink further reveal AWVA's dual advantage: under high-power conditions, the noise-reduction superiority of AWVA over WVA becomes in- creasingly pronounced as input laser power increases, whereas in detection-limited regimes AWVA achieves an order-of-magnitude lower uncertainty, closely approaching the Cram\'er-Rao bound. Crucially, this work demonstrates that AWVA improves precision in both high-power (laser-noise-dominated) and photon-starved (detector-noise-dominated) regimes, thereby bridging these operating extremes and advancing precision in applications from gravitational-wave detection to hybrid quantum systems.
Abstract Even though weak measurements and weak value amplification (WVA) are founded on the principles of quantum mechanics and quantum measurements, these have found widespread applications in optics due to their inherent origin in wave interference. Besides their use in addressing foundational questions of quantum mechanics or for resolving quantum paradoxes, weak measurements and WVA have thus been used for numerous metrological applications, e.g., quantification of small optical beam displacement, tiny angular rotation, determination of extremely small phase shifts, spectral shifts, unraveling weak fundamental optical effects, improved optical imaging, amplifying weak signal and extracting small physical parameters and so forth. In this review, after providing the mathematical foundation of weak measurement and WVA, some of the metrological applications of weak measurements in the classical optics domain are briefly summarized, and the controversies and debates on the potential advantages of WVA in the estimation and detection of weak signal are discussed, and the interferometric philosophy of WVA is elucidated. The experimental weak measurement and WVA schemes in the domain of quantum optics are also discussed and highlighted the new perspectives and emerging trends of weak measurements in both the classical and quantum optics domain and their prospects in the development of next‐generation ultra‐sensitive optical devices.