Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2201.13016 · Physical Review A

Fisher information analysis on weak-value-amplification metrology using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

Published Aug 30, 2022• 21 citations
arXivHTMLPDF

Abstract

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.

DOI
10.1103/physreva.106.022619

Related papers

Enhanced weak-value amplification with Schrödinger cat-like states

Krishna Mishra, Gaurav Shukla, Devendra Mishra

Weak-value amplification (WVA) has emerged as an effective technique for detecting extremely small physical parameters by combining weak system–meter interactions with a carefully chosen post-selection strategy. In this paper, we explore how WVA performs when the meter is prepared in a Schrödinger cat-like state (SCS). Using the Fisher information (FI) as the primary figure of merit, we assess the attainable precision in estimating the interaction parameter. We compare the sensitivities of even coherent states (ECSs), odd coherent states (OCSs), and Yurke–Stoler states (YSSs) against coherent states (CS). We demonstrate that ECS and OCS as meters provide higher FI than the CS as a meter in some cases, depending on the measurement strategy. Also, ECS yields the largest conventional FI among the four meter states. Furthermore, we explore the impact of vacuum superposition with the meter on FI. We find that optimizing the vacuum coefficient enhances the FI in some conditions. This study shows that SCSs can be useful as meter states for improving precision in weak-measurement metrology.

Journal of the Optical Society of America B•Oct 8, 2026•0 citations

Transfer of Fisher information in quantum postselection metrology

Zi-Rui Zhong, Ke-Xuan Chen, Xia-Lin Su +4 more

Abstract Postselected weak measurement has shown significant potential for detecting small physical effects due to its unique weak-value-amplification phenomenon. Previous works suggest that Heisenberg-limit precision can be attained using optical coherent states. However, the observed Heisenberg scaling requires a measurement of the distribution of postselection probability, exhibiting no implementation pathway through conventional measurement paradigms. Here, we demonstrate that the output photons can also reach the Heisenberg scale by utilizing the Fisher information transfer effect, while this scenario exhibits enhanced robustness against dephasing noise. In addition, we consider the insertion of a power-recycling cavity and demonstrate its positive impact on the distribution of postselection. Our results enhance the quantum metrological advantages of the postselection strategy and broaden its application scope.

arXiv:2412.04838•Chinese Physics B•Oct 30, 2025•2 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Heisenberg-Limited Metrology via Weak-Value Amplification without Using Entangled Resources

Yosep Kim, Seung-Yeun Yoo, Yoon-Ho Kim

Weak-value amplification (WVA) provides a way for amplified detection of a tiny physical signal at the expense of a lower detection probability. Despite this trade-off, due to its robustness against certain types of noise, WVA has advantages over conventional measurements in precision metrology. Moreover, it has been shown that WVA-based metrology can reach the Heisenberg limit using entangled resources, but preparing macroscopic entangled resources remains challenging. Here, we demonstrate a novel WVA scheme based on iterative interactions, achieving the Heisenberg-limited precision scaling without resorting to entanglement. This indicates that the perceived advantages of the entanglement-assisted WVA are in fact due to iterative interactions between each particle of an entangled system and a meter, rather than coming from the entanglement itself. Our work opens a practical pathway for achieving the Heisenberg-limited WVA without using fragile and experimentally demanding entangled resources.

arXiv:2109.03762•Physical Review Letters•Jan 25, 2022•38 citations

Implementation of weak measurement amplification with the weak coherent light and optomechanical system

Gang Li, Wen Yang

Abstract Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror’s position displacement of one photon. In the weak value amplification (WVA) regime, the weak value of one photon can lie outside the eigenvalue spectrum, proportional to the difference of the mirror’s position displacement between the successful and failed postselection and its successful postselection probability is dependent of the mean photon number of the coherent light and improved by adjusting it accordingly. Outside the WVA regime, the amplification limit can reach the level of the vacuum fluctuations, and when the mean photon number and the optomechanical coupling parameter are selected appropriately, its successful postselection probability becomes higher, which is beneficial to observe the maximum amplification value under the current experimental conditions. This result breaks the constraint that it is difficult to detect outside the WVA regime. This opens up a new regime for the study of a single photon nonlinearity in optomechanical system.

arXiv:2104.03561•Journal of Physics B Atomic Molecular and Optical Physics•Jun 9, 2021•2 citations

Advantage of quantum coherence in postselected metrology

Shao-Jie Xiong, Wei, Peng-Fei, Huang-Qiu-Chen Wang +5 more

In conventional measurement, to reach the greatest accuracy of parameter estimation, all samples must be measured since each independent sample contains the same quantum Fisher information. In postselected metrology, postselection can concentrate the quantum Fisher information of the initial samples into a tiny post-selected sub-ensemble. It has been proven that this quantum advantage can not be realized in any classically commuting theory. In this work, we present that the advantage of postselection in weak value amplification (WVA) can not be achieved without quantum coherence. The quantum coherence of the initial system is closely related to the preparation costs and measurement costs in parameter estimation. With the increase of initial quantum coherence, the joint values of preparation costs and measurement costs can be optimized to smaller. Moreover, we derive an analytical tradeoff relation between the preparation, measurement and the quantum coherence. We further experimentally test the tradeoff relation in a linear optical setup. The experimental and theoretical results are in good agreement and show that the quantum coherence plays a key role in bounding the resource costs in the postselected metrology process.

arXiv:2212.05285•Dec 10, 2022•1 citation
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.
Weak-value amplification (WVA) has emerged as an effective technique for detecting extremely small physical parameters by combining weak system–meter interactions with a carefully chosen post-selection strategy. In this paper, we explore how WVA performs when the meter is prepared in a Schrödinger cat-like state (SCS). Using the Fisher information (FI) as the primary figure of merit, we assess the attainable precision in estimating the interaction parameter. We compare the sensitivities of even coherent states (ECSs), odd coherent states (OCSs), and Yurke–Stoler states (YSSs) against coherent states (CS). We demonstrate that ECS and OCS as meters provide higher FI than the CS as a meter in some cases, depending on the measurement strategy. Also, ECS yields the largest conventional FI among the four meter states. Furthermore, we explore the impact of vacuum superposition with the meter on FI. We find that optimizing the vacuum coefficient enhances the FI in some conditions. This study shows that SCSs can be useful as meter states for improving precision in weak-measurement metrology.
Abstract Postselected weak measurement has shown significant potential for detecting small physical effects due to its unique weak-value-amplification phenomenon. Previous works suggest that Heisenberg-limit precision can be attained using optical coherent states. However, the observed Heisenberg scaling requires a measurement of the distribution of postselection probability, exhibiting no implementation pathway through conventional measurement paradigms. Here, we demonstrate that the output photons can also reach the Heisenberg scale by utilizing the Fisher information transfer effect, while this scenario exhibits enhanced robustness against dephasing noise. In addition, we consider the insertion of a power-recycling cavity and demonstrate its positive impact on the distribution of postselection. Our results enhance the quantum metrological advantages of the postselection strategy and broaden its application scope.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
Weak-value amplification (WVA) provides a way for amplified detection of a tiny physical signal at the expense of a lower detection probability. Despite this trade-off, due to its robustness against certain types of noise, WVA has advantages over conventional measurements in precision metrology. Moreover, it has been shown that WVA-based metrology can reach the Heisenberg limit using entangled resources, but preparing macroscopic entangled resources remains challenging. Here, we demonstrate a novel WVA scheme based on iterative interactions, achieving the Heisenberg-limited precision scaling without resorting to entanglement. This indicates that the perceived advantages of the entanglement-assisted WVA are in fact due to iterative interactions between each particle of an entangled system and a meter, rather than coming from the entanglement itself. Our work opens a practical pathway for achieving the Heisenberg-limited WVA without using fragile and experimentally demanding entangled resources.
Abstract Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror’s position displacement of one photon. In the weak value amplification (WVA) regime, the weak value of one photon can lie outside the eigenvalue spectrum, proportional to the difference of the mirror’s position displacement between the successful and failed postselection and its successful postselection probability is dependent of the mean photon number of the coherent light and improved by adjusting it accordingly. Outside the WVA regime, the amplification limit can reach the level of the vacuum fluctuations, and when the mean photon number and the optomechanical coupling parameter are selected appropriately, its successful postselection probability becomes higher, which is beneficial to observe the maximum amplification value under the current experimental conditions. This result breaks the constraint that it is difficult to detect outside the WVA regime. This opens up a new regime for the study of a single photon nonlinearity in optomechanical system.
In conventional measurement, to reach the greatest accuracy of parameter estimation, all samples must be measured since each independent sample contains the same quantum Fisher information. In postselected metrology, postselection can concentrate the quantum Fisher information of the initial samples into a tiny post-selected sub-ensemble. It has been proven that this quantum advantage can not be realized in any classically commuting theory. In this work, we present that the advantage of postselection in weak value amplification (WVA) can not be achieved without quantum coherence. The quantum coherence of the initial system is closely related to the preparation costs and measurement costs in parameter estimation. With the increase of initial quantum coherence, the joint values of preparation costs and measurement costs can be optimized to smaller. Moreover, we derive an analytical tradeoff relation between the preparation, measurement and the quantum coherence. We further experimentally test the tradeoff relation in a linear optical setup. The experimental and theoretical results are in good agreement and show that the quantum coherence plays a key role in bounding the resource costs in the postselected metrology process.