arXiv:1606.03478 · Physical Review A

Achieving metrological precision limits through postselection

G. B. Alves, Arthur Pimentel, Malena O. Hor-Meyll, Stephen Patrick Walborn, L. Davidovich, R. L. de Matos Filho

Published Jan 6, 2017• 16 citations
arXivHTMLPDF

Abstract

Postselection strategies have been proposed with the aim of amplifying weak signals, which may help to overcome detection thresholds associated with technical noise in high-precision measurements. Here we use an optical setup to experimentally explore two different postselection protocols for the estimation of a small parameter: a weak-value amplification procedure and an alternative method that does not provide amplification but nonetheless is shown to be more robust for the sake of parameter estimation. Each technique leads approximately to the saturation of quantum limits for the estimation precision, expressed by the Cram\'er-Rao bound. For both situations, we show that parameter estimation is improved when the postselection statistics are considered together with the measurement device.

DOI
10.1103/physreva.95.012104

Related papers

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Entanglement-Assisted Weak Value Amplification

Shengshi Pang, Justin Dressel, Todd A. Brun

Large weak values have been used to amplify the sensitivity of a linear response signal for detecting changes in a small parameter, which has also enabled a simple method for precise parameter estimation. However, producing a large weak value requires a low postselection probability for an ancilla degree of freedom, which limits the utility of the technique. We propose an improvement to this method that uses entanglement to increase the efficiency. We show that by entangling and postselecting n ancillas, the postselection probability can be increased by a factor of n while keeping the weak value fixed (compared to n uncorrelated attempts with one ancilla), which is the optimal scaling with n that is expected from quantum metrology. Furthermore, we show the surprising result that the quantum Fisher information about the detected parameter can be almost entirely preserved in the postselected state, which allows the sensitive estimation to approximately saturate the relevant quantum Cramér-Rao bound. To illustrate this protocol we provide simple quantum circuits that can be implemented using current experimental realizations of three entangled qubits.

arXiv:1401.5887•Physical Review Letters•Jul 15, 2014•109 citations

Information amplification via postselection: A parameter-estimation perspective

Saki Tanaka, Naoki Yamamoto

It is known that weak measurement can significantly amplify the mean of measurement results, sometimes out of the range limited in usual quantum measurement. This fact, as actively demonstrated recently in both theory and experiment, implies the possibility to estimate a very small parameter using the weak measurement technique. But does the weak measurement really bring about the increase of ``information'' for parameter estimation? This paper clarifies that, in a general situation, the answer is NO; more precisely, the weak measurement cannot further decrease the lower bound of the estimation error, i.e., the so-called Cram\'er-Rao bound, which is proportional to the inverse of the quantum Fisher information.

arXiv:1306.2409•Physical Review A•Oct 21, 2013•128 citations

Weak Value Amplification is Suboptimal for Estimation and Detection

Christopher Ferrie, Joshua Combes

We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

arXiv:1307.4016•Physical Review Letters•Jan 31, 2014•218 citations

Estimation of an optomechanical parameter via weak-value amplification

Sergio Carrasco, Miguel Orszag

In this article we present an experimental proposal for the estimation of an optomechanical parameter in the presence of noise. The estimation is based on the technique of weak-value amplification which can enlarge the radiation pressure effect of a single photon on a mechanical oscillator. In our setup we show that the weak-value amplification technique is preferable for the estimation over a method that relies on a strong measurement with postselection because the first method does not require a good prior knowledge of the parameter we wish to estimate, while both strategies reach the same level of precision from a Fisher information perspective. In the presence of strongly correlated noise, the weak-value amplification method is preferable, from a Fisher information perspective, than a standard measurement strategy that does not employ postselection and that is affected by the same type of noise.

arXiv:1902.09247•Physical Review A•Apr 11, 2022•8 citations

Quantum sensors based on weak-value amplification cannot overcome decoherence

George C. Knee, G. Andrew D. Briggs, Simon C. Benjamin +1 more

Sensors that harness exclusively quantum phenomena (such as entanglement) can achieve superior performance compared to those employing only classical principles. Recently, a technique based on postselected, weakly performed measurements has emerged as a method of overcoming technical noise in the detection and estimation of small interaction parameters, particularly in optical systems. The question of which other types of noise may be combated remains open. We here analyze whether the effect can overcome decoherence in a typical field-sensing scenario. Benchmarking a weak, postselected measurement strategy against a strong, direct strategy, we conclude that no advantage is achievable, and that even a small amount of decoherence proves catastrophic to the weak-value amplification technique.

arXiv:1211.0261•Physical Review A•Jan 16, 2013•56 citations
Postselection strategies have been proposed with the aim of amplifying weak signals, which may help to overcome detection thresholds associated with technical noise in high-precision measurements. Here we use an optical setup to experimentally explore two different postselection protocols for the estimation of a small parameter: a weak-value amplification procedure and an alternative method that does not provide amplification but nonetheless is shown to be more robust for the sake of parameter estimation. Each technique leads approximately to the saturation of quantum limits for the estimation precision, expressed by the Cram'er-Rao bound. For both situations, we show that parameter estimation is improved when the postselection statistics are considered together with the measurement device.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
Large weak values have been used to amplify the sensitivity of a linear response signal for detecting changes in a small parameter, which has also enabled a simple method for precise parameter estimation. However, producing a large weak value requires a low postselection probability for an ancilla degree of freedom, which limits the utility of the technique. We propose an improvement to this method that uses entanglement to increase the efficiency. We show that by entangling and postselecting n ancillas, the postselection probability can be increased by a factor of n while keeping the weak value fixed (compared to n uncorrelated attempts with one ancilla), which is the optimal scaling with n that is expected from quantum metrology. Furthermore, we show the surprising result that the quantum Fisher information about the detected parameter can be almost entirely preserved in the postselected state, which allows the sensitive estimation to approximately saturate the relevant quantum Cramér-Rao bound. To illustrate this protocol we provide simple quantum circuits that can be implemented using current experimental realizations of three entangled qubits.
It is known that weak measurement can significantly amplify the mean of measurement results, sometimes out of the range limited in usual quantum measurement. This fact, as actively demonstrated recently in both theory and experiment, implies the possibility to estimate a very small parameter using the weak measurement technique. But does the weak measurement really bring about the increase of ``information'' for parameter estimation? This paper clarifies that, in a general situation, the answer is NO; more precisely, the weak measurement cannot further decrease the lower bound of the estimation error, i.e., the so-called Cram\'er-Rao bound, which is proportional to the inverse of the quantum Fisher information.
We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.
In this article we present an experimental proposal for the estimation of an optomechanical parameter in the presence of noise. The estimation is based on the technique of weak-value amplification which can enlarge the radiation pressure effect of a single photon on a mechanical oscillator. In our setup we show that the weak-value amplification technique is preferable for the estimation over a method that relies on a strong measurement with postselection because the first method does not require a good prior knowledge of the parameter we wish to estimate, while both strategies reach the same level of precision from a Fisher information perspective. In the presence of strongly correlated noise, the weak-value amplification method is preferable, from a Fisher information perspective, than a standard measurement strategy that does not employ postselection and that is affected by the same type of noise.
Sensors that harness exclusively quantum phenomena (such as entanglement) can achieve superior performance compared to those employing only classical principles. Recently, a technique based on postselected, weakly performed measurements has emerged as a method of overcoming technical noise in the detection and estimation of small interaction parameters, particularly in optical systems. The question of which other types of noise may be combated remains open. We here analyze whether the effect can overcome decoherence in a typical field-sensing scenario. Benchmarking a weak, postselected measurement strategy against a strong, direct strategy, we conclude that no advantage is achievable, and that even a small amount of decoherence proves catastrophic to the weak-value amplification technique.