Design and implementation of A 06 GHz - 09 GHz RF-SQUID Read-out system and investigation of rf-SQUID signal characteristics

Taylan Eker

Published Jan 1, 2005• 0 citations
OpenAlex

Abstract

Design and implementation of a transceiver system for rf-SQUID (Superconducting Quantum Interference Device) operation is investigated in this work. Besides, experiments to characterize the rf-SQUID have been performed using the implemented system. The steps in system design and implementation are presented. The difficulties and drawbacks of the system are reported and alternative techniques required to overcome these problems are determined. Also, for the operation of the rf-SQUID at much higher frequencies, different transceiver architecture is proposed and possible drawbacks are stated. Using implemented system, several experiments were performed on two high Tc rfSQUID gradiometers with a tank-circuit resonating at 720 MHz. In these experiments, the frequency and amplitude of the applied rf signal were swept and output flux to voltage transfer signal (modulation added by rf-SQUID), Vspp, and incoming rf signal spectrum are reported and analyzed.

Related papers

Radio‐Frequency (rf) SQUID

Yi Zhang, Hui Dong, Hans‐Joachim Krause +2 more

To read out radio frequency (rf) superconducting quantum interference device (SQUID) signals, an rf resonance tank circuit is usually needed. Similar to dc SQUID systems, an rf SQUID system also detects a flux signal that can change slowly over time. In fact, rf SQUID readout electronics exhibit potential advantages over dc SQUID electronics in the direct readout scheme. A merit of rf SQUID systems is the need for just one coaxial cable to connect the readout electronics to the two-terminal element. In a complete magnetometric SQUID system, an input coil connects to a receiver loop (flux antenna) to pick up the measured signals and couples it to the SQUID via a mutual inductance. This chapter discusses the main differences between rf SQUIDs and dc SQUIDs. The significant difference between rf and DC SQUIDs is the occurrence of higher harmonic components in the flux-to-voltage characteristics.

Wiley eBooks•May 29, 2020•0 citations

High-TC rf superconducting quantum interference device readout with a cryogenic preamplifier

Dongfeng He, M. Tachiki, Hideo Itozaki

A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.

Review of Scientific Instruments•Jun 1, 2006•0 citations

A readout system for 3-GHz rf-SQUIDs

Michael Mück

The layout and construction of a readout electronics for rf superconducting quantum interference devices (SQUIDs) with bias frequencies of 3 GHz are described. The electronics uses standard electronic components and can be aligned using a spectrum analyzer. Differences between a conventional 20-MHz electronics and this microwave readout are explained. Each individual circuit block is described and circuit diagrams as well as information for pc-board layout is given. A brief description of thin-film rf-SQUIDs used for experiments with this readout electronics is also included.

Review of Scientific Instruments•Apr 1, 1992•14 citations

Experimental study of amplitude–frequency characteristics of high-transition-temperature radio frequency superconducting quantum interference devices

Xian-Lin Zeng, Y. Zhang, Boris Chesca +3 more

We measured the amplitude–frequency characteristics of radio frequency superconducting quantum interference devices (rf SQUIDs) over a temperature range between 65 and 79 K. Using the expressions derived from the recently developed rf SQUID theory, valid also at large thermal fluctuations, we determined from these data the basic parameters of high-transition-temperature superconductor (HTS) rf SQUIDs. These parameters were: (a) the high-frequency coupling coefficient between the rf SQUID and the tank circuit resonator, k, (b) the SQUIDs hysteretic parameter, β, (c) the critical current of the Josephson junction, Ic, (d) its normal resistance, Rn, and (e) its noise parameter, Γ. We found a good agreement with the values of β(Ic) and Rn determined directly after destructively opening the SQUID loop. In accordance with the theoretical predictions, our experimental results show that at large thermal fluctuation levels (T≅77 K), rf SQUIDs with large loop inductance operate in nonhysteretic mode up to β values exceeding 3. Furthermore, we have shown that the optimal energy sensitivity is attained in the nonhysteretic mode at a value of β distinctly higher than 1. A quantitative comparison of white noise predicted by the theory with that obtained from the experiment showed a reasonable agreement. We also discussed the contribution of the phase information to the SQUID’s signal and noise at optimum operation conditions, when a mixer was used as a signal detector.

Journal of Applied Physics•Dec 1, 2000•14 citations

Use of super Schottky diodes in a cryogenic radio frequency superconducting quantum interference device readout

Michael Mück, Th. Becker, Christoph Heiden

We describe the fabrication and characterization of super Schottky diodes which are used in the cryogenic part of a 3 GHz radio frequency superconducting quantum interference device (rf SQUID) readout electronics. The diodes were prepared on silicon wafers with an n-doping level of 5×1024 m−3. They exhibited sensitivities of 1500 V−1 at 4.2 K, and a noise equivalent power of 2×10−15 W/√Hz was measured at 2.1 GHz. Using planar niobium 3 GHz rf SQUIDs and a cooled rf amplifier, experiments have been performed to investigate the feasibility of these super Schottky diodes for demodulation of the SQUID rf signal voltage. A simple cryogenic rf SQUID readout, employing two transistors and one super Schottky diode is described and investigated. Flux noise measurements in an open loop have been performed using this readout.

Applied Physics Letters•Jan 16, 1995•2 citations

Radio frequency pumped superconducting quantum interference devices with two quantization loops

G.S. Krivoy, H. Koch

Conventional rf SQUIDs (superconducting quantum interference devices) consist of a superconducting loop interrupted by one weak link, and when read out via a tank circuit they produce output signals in the order of a few tens of microvolts. When the single weak link is replaced by a dc SQUID (a superconducting loop with two junctions) a so-called double quantization loop SQUID is formed. In this paper it is shown theoretically, and supported experimentally with thin-film devices of three different designs, that the general behaviour can be explained by a simplified picture of the fixed critical current of the single junction of the rf SQUID being replaced by an effective critical current of a dc SQUID loop that is varied by the applied magnetic flux (i.e., we have a rf SQUID with a variable β parameter). A more detailed analysis of the experimental data and the theory of this novel device reveals its interesting nonlinear character and shows the deviations from this simple picture. It is demonstrated experimentally that output signals in the order of ≥1 mV can be obtained with a suitable read-out mode for the tank circuit, a clear advantage when compared to conventional rf SQUIDs. With respect to dc SQUIDs, the coupling to integrated planar input coils will be unproblematic since no microwave resonances should occur in the structures.

Journal of Applied Physics•Aug 15, 1993•16 citations
Design and implementation of a transceiver system for rf-SQUID (Superconducting Quantum Interference Device) operation is investigated in this work. Besides, experiments to characterize the rf-SQUID have been performed using the implemented system. The steps in system design and implementation are presented. The difficulties and drawbacks of the system are reported and alternative techniques required to overcome these problems are determined. Also, for the operation of the rf-SQUID at much higher frequencies, different transceiver architecture is proposed and possible drawbacks are stated. Using implemented system, several experiments were performed on two high Tc rfSQUID gradiometers with a tank-circuit resonating at 720 MHz. In these experiments, the frequency and amplitude of the applied rf signal were swept and output flux to voltage transfer signal (modulation added by rf-SQUID), Vspp, and incoming rf signal spectrum are reported and analyzed.
To read out radio frequency (rf) superconducting quantum interference device (SQUID) signals, an rf resonance tank circuit is usually needed. Similar to dc SQUID systems, an rf SQUID system also detects a flux signal that can change slowly over time. In fact, rf SQUID readout electronics exhibit potential advantages over dc SQUID electronics in the direct readout scheme. A merit of rf SQUID systems is the need for just one coaxial cable to connect the readout electronics to the two-terminal element. In a complete magnetometric SQUID system, an input coil connects to a receiver loop (flux antenna) to pick up the measured signals and couples it to the SQUID via a mutual inductance. This chapter discusses the main differences between rf SQUIDs and dc SQUIDs. The significant difference between rf and DC SQUIDs is the occurrence of higher harmonic components in the flux-to-voltage characteristics.
A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.
The layout and construction of a readout electronics for rf superconducting quantum interference devices (SQUIDs) with bias frequencies of 3 GHz are described. The electronics uses standard electronic components and can be aligned using a spectrum analyzer. Differences between a conventional 20-MHz electronics and this microwave readout are explained. Each individual circuit block is described and circuit diagrams as well as information for pc-board layout is given. A brief description of thin-film rf-SQUIDs used for experiments with this readout electronics is also included.
We measured the amplitude–frequency characteristics of radio frequency superconducting quantum interference devices (rf SQUIDs) over a temperature range between 65 and 79 K. Using the expressions derived from the recently developed rf SQUID theory, valid also at large thermal fluctuations, we determined from these data the basic parameters of high-transition-temperature superconductor (HTS) rf SQUIDs. These parameters were: (a) the high-frequency coupling coefficient between the rf SQUID and the tank circuit resonator, k, (b) the SQUIDs hysteretic parameter, β, (c) the critical current of the Josephson junction, Ic, (d) its normal resistance, Rn, and (e) its noise parameter, Γ. We found a good agreement with the values of β(Ic) and Rn determined directly after destructively opening the SQUID loop. In accordance with the theoretical predictions, our experimental results show that at large thermal fluctuation levels (T≅77 K), rf SQUIDs with large loop inductance operate in nonhysteretic mode up to β values exceeding 3. Furthermore, we have shown that the optimal energy sensitivity is attained in the nonhysteretic mode at a value of β distinctly higher than 1. A quantitative comparison of white noise predicted by the theory with that obtained from the experiment showed a reasonable agreement. We also discussed the contribution of the phase information to the SQUID’s signal and noise at optimum operation conditions, when a mixer was used as a signal detector.
We describe the fabrication and characterization of super Schottky diodes which are used in the cryogenic part of a 3 GHz radio frequency superconducting quantum interference device (rf SQUID) readout electronics. The diodes were prepared on silicon wafers with an n-doping level of 5×1024 m−3. They exhibited sensitivities of 1500 V−1 at 4.2 K, and a noise equivalent power of 2×10−15 W/√Hz was measured at 2.1 GHz. Using planar niobium 3 GHz rf SQUIDs and a cooled rf amplifier, experiments have been performed to investigate the feasibility of these super Schottky diodes for demodulation of the SQUID rf signal voltage. A simple cryogenic rf SQUID readout, employing two transistors and one super Schottky diode is described and investigated. Flux noise measurements in an open loop have been performed using this readout.
Conventional rf SQUIDs (superconducting quantum interference devices) consist of a superconducting loop interrupted by one weak link, and when read out via a tank circuit they produce output signals in the order of a few tens of microvolts. When the single weak link is replaced by a dc SQUID (a superconducting loop with two junctions) a so-called double quantization loop SQUID is formed. In this paper it is shown theoretically, and supported experimentally with thin-film devices of three different designs, that the general behaviour can be explained by a simplified picture of the fixed critical current of the single junction of the rf SQUID being replaced by an effective critical current of a dc SQUID loop that is varied by the applied magnetic flux (i.e., we have a rf SQUID with a variable β parameter). A more detailed analysis of the experimental data and the theory of this novel device reveals its interesting nonlinear character and shows the deviations from this simple picture. It is demonstrated experimentally that output signals in the order of ≥1 mV can be obtained with a suitable read-out mode for the tank circuit, a clear advantage when compared to conventional rf SQUIDs. With respect to dc SQUIDs, the coupling to integrated planar input coils will be unproblematic since no microwave resonances should occur in the structures.