Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

High-TC rf superconducting quantum interference device readout with a cryogenic preamplifier

Dongfeng He, M. Tachiki, Hideo Itozaki

Published Jun 1, 2006• 0 citations
Publisher

Abstract

A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.

DOI
10.1063/1.2216852

Related papers

Cryogenic direct current superconducting quantum interference device readout circuit

Michael Mück, Matthias Korn, Chas Mugford +1 more

We have designed and tested a superconducting quantum interference device (SQUID) readout circuit, which can be operated at liquid helium temperatures. Although room-temperature SQUID electronics perform well, it is sometimes desirable to keep the wires between SQUID, readout electronics, and feedback coil as short as possible to minimize phase shifts and time delays. Cooling the readout circuit to low temperatures can also decrease its thermal noise. Our readout circuit uses conventional ac-flux modulation, which significantly reduces low frequency excess noise and drift in the preamplifier. In this case, simple complementary metal–oxide–semiconductor circuits with low power dissipation can be used as amplifier, phase-sensitive detector and integrator. The power dissipation of the complete readout is less than 15mW at 5V supply voltage.

Review of Scientific Instruments•Jun 27, 2005•4 citations

1/f noise in radio frequency SQUIDs made of niobium thin films

Michael Mueck, John L. Clarke, Christoph Heiden

Applications of Superconducting Quantum Interference Devices (SQUIDs) usually require high sensitivity at relatively low frequencies, often down to 1 Hz or lower. Excess noise, typically with a spectral density scaling inversely as the frequency, can substantially reduce the sensitivity of SQUIDs at low frequencies. We have studied 1/f noise in niobium rf-SQUIDs in some detail. To reduce any noise contribution of the readout electronics, a cryogenic preamplifier was used. When one measures the signal voltage of the SQUID directly, a pronounced 1/f noise was observed in all samples, and was nearly independent of the bias frequency used. The crossover between 1/f and white noise moved towards higher frequencies as the bias frequency was increased, because of a lower white noise contribution. The 1/f noise scaled approximately as the inductance of the SQUID. When operated in a flux locked loop, however, no 1/f noise could be observed above 0.5 Hz. Operating a rf SQUID in a flux locked loop can thus substantially reduce 1/f noise in rf SQUIDs.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 2, 1994•0 citations

Operation of high-temperature rf SQUID magnetometers using dielectric SrTiO3 resonators

Y. Zhang, M. Gottschlich, Helmut Soltner +4 more

The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.

Applied Physics Letters•Nov 20, 1995•16 citations

Investigation of silicon field-effect transistors in cryogenic amplifiers for radio frequency superconducting quantum interference devices

T. Becker, Michael Mück, Christoph Heiden

We have prepared n-channel silicon field-effect transistors, which are capable of working at liquid helium temperatures (4.2 K) and used them in cooled preamplifiers for rf superconducting quantum interference device (SQUID) readout electronics. All metallizations of these transistors were made of niobium, to study the possibility of a further integration of a SQUID and FET on the same chip. Using the FETs in a cooled preamplifier together with a rf SQUID gradiometer, the flux noise of the system could be reduced by a factor of 3 compared to a room temperature low noise preamplifier. We have also performed calculations of a possible increase of the substrate temperature due to the power dissipation of the FET and have measured the cross talk between FET and SQUID.

Review of Scientific Instruments•May 1, 1995•0 citations

Two-stage amplifier based on a double relaxation oscillation superconducting quantum interference device

M. Podt, Michiel J. van Duuren, A.W. Hamster +2 more

A low-noise single-chip two-stage superconducting quantum interference device (SQUID) system with a double relaxation oscillation SQUID as the second stage has been realized. The system was operated in a direct voltage readout mode, with a closed loop bandwidth up to 1 MHz. Operated at 4.2 K, the white flux noise measured in flux locked loop was 1.3 μΦ0/√Hz, corresponding to an energy sensitivity of ε≈27h. Owing to the large flux-to-voltage transfer of up to 3.6 mV/Φ0, the room-temperature preamplifier noise did not dominate the overall flux noise.

Applied Physics Letters•Oct 11, 1999•25 citations

Improved sensitivity of planar microwave based RF-SQUIDs using a cryogenic HEMT preamplifier

Giorgio Fontana, R. Mezzena, Stefano Vitale +4 more

The design and performance of a planar microwave RF-SQUID (superconducting quantum interference device) read out by a cryogenic high-electron-mobility-transistor (HEMT) preamplifier are described. The SQUID sensor consists of a planar half-wavelength microstrip resonator, into which the SQUID loop is integrated. The SQUID is operated at a pump frequency of 1.7 GHz. The cryogenic preamplifier uses a microwave HEMT, located close to the SQUID sensor. Measurements of the flux noise and the fractional step rise parameter were carried out in the temperature range between 4.2 K and 1.5 K. In an open loop, a flux noise of 2*10/sup -6/ Phi /sub 0// square root Hz was measured at 4.2 K, resulting in an energy resolution of about 100 h. The design of a 3-GHz magnetometer is also described, and the preliminary results of the measurements are reported.>

IEEE Transactions on Applied Superconductivity•Mar 1, 1993•5 citations
A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.
We have designed and tested a superconducting quantum interference device (SQUID) readout circuit, which can be operated at liquid helium temperatures. Although room-temperature SQUID electronics perform well, it is sometimes desirable to keep the wires between SQUID, readout electronics, and feedback coil as short as possible to minimize phase shifts and time delays. Cooling the readout circuit to low temperatures can also decrease its thermal noise. Our readout circuit uses conventional ac-flux modulation, which significantly reduces low frequency excess noise and drift in the preamplifier. In this case, simple complementary metal–oxide–semiconductor circuits with low power dissipation can be used as amplifier, phase-sensitive detector and integrator. The power dissipation of the complete readout is less than 15mW at 5V supply voltage.
Applications of Superconducting Quantum Interference Devices (SQUIDs) usually require high sensitivity at relatively low frequencies, often down to 1 Hz or lower. Excess noise, typically with a spectral density scaling inversely as the frequency, can substantially reduce the sensitivity of SQUIDs at low frequencies. We have studied 1/f noise in niobium rf-SQUIDs in some detail. To reduce any noise contribution of the readout electronics, a cryogenic preamplifier was used. When one measures the signal voltage of the SQUID directly, a pronounced 1/f noise was observed in all samples, and was nearly independent of the bias frequency used. The crossover between 1/f and white noise moved towards higher frequencies as the bias frequency was increased, because of a lower white noise contribution. The 1/f noise scaled approximately as the inductance of the SQUID. When operated in a flux locked loop, however, no 1/f noise could be observed above 0.5 Hz. Operating a rf SQUID in a flux locked loop can thus substantially reduce 1/f noise in rf SQUIDs.
The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.
We have prepared n-channel silicon field-effect transistors, which are capable of working at liquid helium temperatures (4.2 K) and used them in cooled preamplifiers for rf superconducting quantum interference device (SQUID) readout electronics. All metallizations of these transistors were made of niobium, to study the possibility of a further integration of a SQUID and FET on the same chip. Using the FETs in a cooled preamplifier together with a rf SQUID gradiometer, the flux noise of the system could be reduced by a factor of 3 compared to a room temperature low noise preamplifier. We have also performed calculations of a possible increase of the substrate temperature due to the power dissipation of the FET and have measured the cross talk between FET and SQUID.
A low-noise single-chip two-stage superconducting quantum interference device (SQUID) system with a double relaxation oscillation SQUID as the second stage has been realized. The system was operated in a direct voltage readout mode, with a closed loop bandwidth up to 1 MHz. Operated at 4.2 K, the white flux noise measured in flux locked loop was 1.3 μΦ0/√Hz, corresponding to an energy sensitivity of ε≈27h. Owing to the large flux-to-voltage transfer of up to 3.6 mV/Φ0, the room-temperature preamplifier noise did not dominate the overall flux noise.
The design and performance of a planar microwave RF-SQUID (superconducting quantum interference device) read out by a cryogenic high-electron-mobility-transistor (HEMT) preamplifier are described. The SQUID sensor consists of a planar half-wavelength microstrip resonator, into which the SQUID loop is integrated. The SQUID is operated at a pump frequency of 1.7 GHz. The cryogenic preamplifier uses a microwave HEMT, located close to the SQUID sensor. Measurements of the flux noise and the fractional step rise parameter were carried out in the temperature range between 4.2 K and 1.5 K. In an open loop, a flux noise of 2*10/sup -6/ Phi /sub 0// square root Hz was measured at 4.2 K, resulting in an energy resolution of about 100 h. The design of a 3-GHz magnetometer is also described, and the preliminary results of the measurements are reported.>