Conference on Lasers and Electro-Optics

A Compact Physics Package of a Chip-Scale Atomic Clock with a Built-in Magnetic Shield

Hyun-Gue Hong, Jongcheol Park, Tae Hyun Kim, Hee Yeoun Kim, Sang‐Eon Park, Sang-Bum Lee, Myoung-Sun Heo, Taeg Yong Kwon

Published May 5, 2019• 2 citations
Publisher

Abstract

We demonstrate a physics package for chip-scale atomic clocks in which the supporting frame itself serves as a primitive magnetic shield (∼20x attenuation). It measures 4.9×4.9×4.5 mm3 with its frequency instability ∼ 10−10 at 1 s.
DOI
10.23919/cleo.2019.8749652

Related papers

A Compact Physics Package of a Chip-scale Atomic Clock with a Built-in Magnetic Shield

Hyun-Gue Hong, Jongcheol Park, Tae Hyun Kim +5 more

We demonstrate a physics package for chip-scale atomic clocks in which the supporting frame itself serves as a primitive magnetic shield (~20× attenuation). It measures 4.9×4.9×4.5 mm3 with its frequency instability ~10−10 at 1 s.

Conference on Lasers and Electro-Optics•Jan 1, 2019•2 citations

Magnetic shield integration for a chip-scale atomic clock

Hyun-Gue Hong, Jongcheol Park, Tae Hyun Kim +5 more

We introduce a miniaturized magnetic shield integrated into the physics package of a chip-scale atomic clock. The primary shield, which is formed by a stack of precision-machined high-permeability plates, compactly sits inside the package as it is designed to be the internal supporting frame. Further improved by a Kovar lid, the best frequency sensitivity to a longitudinal external field is 1.1(3) × 10 −11 / μ T, which is consistent with the measured shielding factor, while the transverse sensitivity is well below 10 −12 / μ T. The sealed unit on a chip carrier alone allows stable clock operation with a frequency instability of 4.8(2) × 10 −12 at 1000 s.

Applied Physics Express•Sep 8, 2020•12 citations

Microfabricated atomic clocks and magnetometers

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +6 more

We demonstrate the critical subsystems of a compact atomic clock based on a microfabricated physics package. The clock components have a total volume below 10 cm3, a fractional frequency instability of 6 × 10−10/τ1/2, and consume 200 mW of power. The physics package is easily adapted to function as a magnetometer with sensitivity below 50 pT Hz−1/2 at 10 Hz.

Journal of Optics A Pure and Applied Optics•May 31, 2006•70 citations

Microfabricated atomic clocks and magnetometers

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +6 more

We demonstrate the critical subsystems of compact atomic clocks and magnetometers based on microfabricated physics packages. The clock components have a volume below 5 cm3, a fractional frequency instability below 6times10-10tau1/2, and consume 200 mW of power. The magnetometer has a sensitivity below 40pT/Hz1/2at 50 Hz

IEEE/LEOS International Conference on Optical MEMS•Oct 11, 2006•2 citations

Compact atomic clock based on coherent populationtrapping

J. Kitching, Leo W. Hollberg, S. Knappe +1 more

A simple, compact, low-power physics package for a vapour-cell atomic clock is described. The device measures 6.6 × 1.6 × 1.3 cm and dissipates less than 30 mW of electrical power without thermal control. The instability is 1.3 × 10-10/√[τ/(s)] for integration times τ below 100 s. Applications for this device include distributed telecommunications systems, advanced global positioning system (GPS) receivers and laboratory instrumentation.

Electronics Letters•Nov 22, 2001•57 citations

Long-term stability of NIST chip-scale atomic clock physics packages

Svenja A. Knappe, Vladislav P. Gerginov, Vishal Shah +3 more

We discuss the long-term stability of the NIST chip-scale atomic clock (CSAC) physics packages. We identify the major factors that currently limit the frequency stability of our CSAC packages after 100 s. The requirements for the stability of the vapor cell and laser temperature, local magnetic field, and local oscillator output power are evaluated. Due to the small size of CSAC physics package assemblies, advances MEMS packaging techniques for vacuum sealing and thermal isolation can be used to achieve the temperature stability goals. We discuss various ideas on how to aid temperature control solutions over wide variations in ambient temperature by implementing atom-based stabilization schemes. Control of environment-related frequency instabilities will be critical for successful insertion of CSACs into portable instruments in the areas of navigation and communication.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 20, 2007•10 citations
We introduce a miniaturized magnetic shield integrated into the physics package of a chip-scale atomic clock. The primary shield, which is formed by a stack of precision-machined high-permeability plates, compactly sits inside the package as it is designed to be the internal supporting frame. Further improved by a Kovar lid, the best frequency sensitivity to a longitudinal external field is 1.1(3) × 10 −11 / μ T, which is consistent with the measured shielding factor, while the transverse sensitivity is well below 10 −12 / μ T. The sealed unit on a chip carrier alone allows stable clock operation with a frequency instability of 4.8(2) × 10 −12 at 1000 s.
We discuss the long-term stability of the NIST chip-scale atomic clock (CSAC) physics packages. We identify the major factors that currently limit the frequency stability of our CSAC packages after 100 s. The requirements for the stability of the vapor cell and laser temperature, local magnetic field, and local oscillator output power are evaluated. Due to the small size of CSAC physics package assemblies, advances MEMS packaging techniques for vacuum sealing and thermal isolation can be used to achieve the temperature stability goals. We discuss various ideas on how to aid temperature control solutions over wide variations in ambient temperature by implementing atom-based stabilization schemes. Control of environment-related frequency instabilities will be critical for successful insertion of CSACs into portable instruments in the areas of navigation and communication.