Microfabricated atomic clocks and magnetometers

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov, Vishal Shah, Li‐Anne Liew, John Moreland, H. G. Robinson, Leo W. Hollberg, John E. Kitching

Published May 31, 2006• 70 citations
Publisher

Abstract

We demonstrate the critical subsystems of a compact atomic clock based on a microfabricated physics package. The clock components have a total volume below 10 cm3, a fractional frequency instability of 6 × 10−10/τ1/2, and consume 200 mW of power. The physics package is easily adapted to function as a magnetometer with sensitivity below 50 pT Hz−1/2 at 10 Hz.

DOI
10.1088/1464-4258/8/7/s04

Related papers

Microfabricated atomic clocks and magnetometers

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +6 more

We demonstrate the critical subsystems of compact atomic clocks and magnetometers based on microfabricated physics packages. The clock components have a volume below 5 cm3, a fractional frequency instability below 6times10-10tau1/2, and consume 200 mW of power. The magnetometer has a sensitivity below 40pT/Hz1/2at 50 Hz

IEEE/LEOS International Conference on Optical MEMS•Oct 11, 2006•2 citations

MICROFABRICATED ATOMIC CLOCKS AND MAGNETOMETERS

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +4 more

We describe recent research at NIST directed towards the development of microfabricated atomic clocks and magnetometers based on coherent population trapping spectroscopy. Clock physics packages based on the D 1 transition in 87 Rb achieve a fractional frequency instability below 4 × 10 -11 /τ 1/2 [Knappe et al., Appl. Phys. Lett. 85, 1460 (2004)], while the sensitivity of the magnetic sensor reached 50 pT Hz -1/2 at 10 Hz [Schwindt et al. Appl. Phys, Lett. 85, 6509 (2004)]. With volumes around 10 mm 3 and power consumptions below 150 mW they display an improvement over the previous state of the art by a factor of 100 in volume and a factor of 10 in power dissipation.

Laser Spectroscopy•Dec 1, 2005•9 citations

Microfabricated Atomic Magnetometer

Peter D. D. Schwindt, Svenja A. Knappe, Vishal Shah +4 more

Using the techniques of microelectromechanical systems, we are developing chip-scale atomic sensors based on laser excitation of alkali atoms. Recently, we demonstrated a magnetometer physics package based on coherent population trapping that had a sensitivity of 50 pT/Hzfrac12at 10 Hz, had a volume of 12 mm3, and used 195 mW of power as presented by Schwindt et al. (2004). To improve the sensitivity and reduce the power consumption of the magnetometer, we are evaluating other methods of interrogating the atoms for use in microfabricated devices. One of these methods uses frequency modulated nonlinear magneto-optical rotation (FM NMOR). We demonstrate that an FM NMOR magnetometer can be made to self-oscillate, offering simple construction and low power consumption

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Mar 22, 2006•1 citation

Compact atomic clock based on coherent populationtrapping

J. Kitching, Leo W. Hollberg, S. Knappe +1 more

A simple, compact, low-power physics package for a vapour-cell atomic clock is described. The device measures 6.6 × 1.6 × 1.3 cm and dissipates less than 30 mW of electrical power without thermal control. The instability is 1.3 × 10-10/√[τ/(s)] for integration times τ below 100 s. Applications for this device include distributed telecommunications systems, advanced global positioning system (GPS) receivers and laboratory instrumentation.

Electronics Letters•Nov 22, 2001•57 citations

The Chip-Scale Atomic Clock - Low-Power Physics Package

Robert Lutwak, Jinyi Deng, William Riley +7 more

We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.

•Dec 1, 2004•63 citations

Microfabricated Atomic Clocks at NIST

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +5 more

This paper presents the latest progress in the development, fabrication, and characterization of microfabricated atomic frequency references at NIST. With volumes below 10 mm3 the physics packages contain the complete integrated assembly for probing the ground-state hyperfine splitting frequency of the alkali atoms by coherent population trapping (CPT). This technique allows for a simple and compact device containing a vertical-cavity surface-emitting laser (VCSEL), optics to shape the laser beam, a vapor cell containing the atoms, and a detector. We present an improved technique for microfabricating the miniature alkali vapor cells. When integrated into a CPT clock, a clear reduction of long-term frequency drifts is observed. This leads to a fractional frequency instability of less than 10-11 at one hour of integration, a more than one order of magnitude improvement over previous results. We identify the remaining sensitivities of the clock frequency to environmental influences and propose ways to reduce them.

•Dec 1, 2004•3 citations
We demonstrate the critical subsystems of a compact atomic clock based on a microfabricated physics package. The clock components have a total volume below 10 cm3, a fractional frequency instability of 6 × 10−10/τ1/2, and consume 200 mW of power. The physics package is easily adapted to function as a magnetometer with sensitivity below 50 pT Hz−1/2 at 10 Hz.
We describe recent research at NIST directed towards the development of microfabricated atomic clocks and magnetometers based on coherent population trapping spectroscopy. Clock physics packages based on the D 1 transition in 87 Rb achieve a fractional frequency instability below 4 × 10 -11 /τ 1/2 [Knappe et al., Appl. Phys. Lett. 85, 1460 (2004)], while the sensitivity of the magnetic sensor reached 50 pT Hz -1/2 at 10 Hz [Schwindt et al. Appl. Phys, Lett. 85, 6509 (2004)]. With volumes around 10 mm 3 and power consumptions below 150 mW they display an improvement over the previous state of the art by a factor of 100 in volume and a factor of 10 in power dissipation.
Using the techniques of microelectromechanical systems, we are developing chip-scale atomic sensors based on laser excitation of alkali atoms. Recently, we demonstrated a magnetometer physics package based on coherent population trapping that had a sensitivity of 50 pT/Hzfrac12at 10 Hz, had a volume of 12 mm3, and used 195 mW of power as presented by Schwindt et al. (2004). To improve the sensitivity and reduce the power consumption of the magnetometer, we are evaluating other methods of interrogating the atoms for use in microfabricated devices. One of these methods uses frequency modulated nonlinear magneto-optical rotation (FM NMOR). We demonstrate that an FM NMOR magnetometer can be made to self-oscillate, offering simple construction and low power consumption
We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.
This paper presents the latest progress in the development, fabrication, and characterization of microfabricated atomic frequency references at NIST. With volumes below 10 mm3 the physics packages contain the complete integrated assembly for probing the ground-state hyperfine splitting frequency of the alkali atoms by coherent population trapping (CPT). This technique allows for a simple and compact device containing a vertical-cavity surface-emitting laser (VCSEL), optics to shape the laser beam, a vapor cell containing the atoms, and a detector. We present an improved technique for microfabricating the miniature alkali vapor cells. When integrated into a CPT clock, a clear reduction of long-term frequency drifts is observed. This leads to a fractional frequency instability of less than 10-11 at one hour of integration, a more than one order of magnitude improvement over previous results. We identify the remaining sensitivities of the clock frequency to environmental influences and propose ways to reduce them.