Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Long-term stability of NIST chip-scale atomic clock physics packages

Svenja A. Knappe, Vladislav P. Gerginov, Vishal Shah, Alan S. Brannon, Leo W. Hollberg, John E. Kitching

Published Jan 20, 2007• 10 citations
Publisher

Abstract

We discuss the long-term stability of the NIST chip-scale atomic clock (CSAC) physics packages. We identify the major factors that currently limit the frequency stability of our CSAC packages after 100 s. The requirements for the stability of the vapor cell and laser temperature, local magnetic field, and local oscillator output power are evaluated. Due to the small size of CSAC physics package assemblies, advances MEMS packaging techniques for vacuum sealing and thermal isolation can be used to achieve the temperature stability goals. We discuss various ideas on how to aid temperature control solutions over wide variations in ambient temperature by implementing atom-based stabilization schemes. Control of environment-related frequency instabilities will be critical for successful insertion of CSACs into portable instruments in the areas of navigation and communication.

DOI
10.1117/12.701591

Related papers

Long-Term Stability of NIST Chip-Scale Atomic Clock Physics Packages

Svenja A. Knappe, Vishal Shah, Vladislav P. Gerginov +3 more

We present measurements regarding the long-term frequency stability of NIST chip-scale atomic clock (CSAC) physics packages. Changes of the clock frequency are caused mainly through time-dependent light shifts by the frequency-modulated VCSEL and properties of the vapor cell. We suggest advanced CPT interrogation schemes to relax the requirements on the temperature stability of the VCSEL as well as the power of the local oscillator. Finally, we discuss the advantages and limitations of these techniques when implemented into a small package.

•Dec 9, 2006•4 citations

Integrated physics package of a chip-scale atomic clock

Shao-Liang Li, Jing Chao Xu, Zhiqiang Zhang +3 more

The physics package of a chip-scale atomic clock (CSAC) has been successfully realized by integrating vertical cavity surface emitting laser (VCSEL), neutral density (ND) filter, λ/4 wave plate, 87 Rb vapor cell, photodiode (PD), and magnetic coil into a cuboid metal package with a volume of about 2.8 cm 3 . In this physics package, the critical component, 87 Rb vapor cell, is batch-fabricated based on MEMS technology and in-situ chemical reaction method. Pt heater and thermistors are integrated in the physics package. A PTFE pillar is used to support the optical elements in the physics package, in order to reduce the power dissipation. The optical absorption spectrum of 87 Rb D1 line and the microwave frequency correction signal are successfully observed while connecting the package with the servo circuit system. Using the above mentioned packaging solution, a CSAC with short-term frequency stability of about 7 × 10 −10 τ −1/2 has been successfully achieved, which demonstrates that this physics package would become one promising solution for the CSAC.

Chinese Physics B•Jul 1, 2014•14 citations

The Chip-Scale Atomic Clock - Recent Development Progress

Robert Lutwak, Donald A. Emmons, Thomas C. English +1 more

We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.

•Sep 1, 2004•55 citations

CSAC – THE CHIP-SCALE ATOMIC CLOCK

Robert Lutwak, Ahmed Nabih Zaki Rashed, Mathew K. Varghese +6 more

The authors have developed a Chip-Scale Atomic Clock (CSAC) of sufficiently low power and small size to enable atomic timing in portable battery-powered devices. The collaboration of diverse research teams in clock technology, micro-electromechanical systems (MEMS), and optoelectronic devices has resulted in size and power reduction of atomic clock technology by more than two orders of magnitude. In 2007, we completed a pre-production build and evaluation of ten identical CSACs, with power <125 mW and short-term stability of σ y (τ) < 2 × 10 -10 τ -1/2 1 . This paper reviews the physics and engineering considerations which underlie CSAC technology, describes in detail our CSAC implementation, and presents the results from the pre-production build.

Symposium on Frequency Standards and Metrology•May 1, 2009•10 citations

The Chip-Scale Atomic Clock - Low-Power Physics Package

Robert Lutwak, Jinyi Deng, William Riley +7 more

We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.

•Dec 1, 2004•63 citations

Advances of Chip-Scale Atomic Clock in Peking University in 2019

Jianye Zhao, Ping Guo, Lin Dan +1 more

Ever since the idea of the chip-scale atomic clock (CSAC) based on coherent population trapping (CPT) transition theory was proposed, the CSAC has been used widely in many various fields because of its characteristics of low power consumption, small size and good performance. It can be used in micro-positioning navigation and timing system, geophysical prospecting of the ocean bottom, and 5G communication system. Researchers work on reducing its volume and power consumption to make it more widely used. In the meantime, we all made great effort to improve its long-term stability. In this paper, we report our progress toward chip-scale atomic clock based on the87Rb CPT transition during 2019. We reduced the volume of the CSAC from 20 cm3to 12 cm3. For the physical part, we optimized the structure of the physical package to make sure it is possible for mass production. For the electrical part, we redesigned and rearranged the circuit, optimized the temperature control algorithm, employed a disciplining method. Finally, the frequency stability of CSAC was obtained to be 3.66×10-11, 6.39×10-12and 3.42 ×10-13at the interrogation time of 1 s, 103s and 104s respectively.

Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)•Jul 1, 2020•3 citations
We discuss the long-term stability of the NIST chip-scale atomic clock (CSAC) physics packages. We identify the major factors that currently limit the frequency stability of our CSAC packages after 100 s. The requirements for the stability of the vapor cell and laser temperature, local magnetic field, and local oscillator output power are evaluated. Due to the small size of CSAC physics package assemblies, advances MEMS packaging techniques for vacuum sealing and thermal isolation can be used to achieve the temperature stability goals. We discuss various ideas on how to aid temperature control solutions over wide variations in ambient temperature by implementing atom-based stabilization schemes. Control of environment-related frequency instabilities will be critical for successful insertion of CSACs into portable instruments in the areas of navigation and communication.
We present measurements regarding the long-term frequency stability of NIST chip-scale atomic clock (CSAC) physics packages. Changes of the clock frequency are caused mainly through time-dependent light shifts by the frequency-modulated VCSEL and properties of the vapor cell. We suggest advanced CPT interrogation schemes to relax the requirements on the temperature stability of the VCSEL as well as the power of the local oscillator. Finally, we discuss the advantages and limitations of these techniques when implemented into a small package.
The physics package of a chip-scale atomic clock (CSAC) has been successfully realized by integrating vertical cavity surface emitting laser (VCSEL), neutral density (ND) filter, λ/4 wave plate, 87 Rb vapor cell, photodiode (PD), and magnetic coil into a cuboid metal package with a volume of about 2.8 cm 3 . In this physics package, the critical component, 87 Rb vapor cell, is batch-fabricated based on MEMS technology and in-situ chemical reaction method. Pt heater and thermistors are integrated in the physics package. A PTFE pillar is used to support the optical elements in the physics package, in order to reduce the power dissipation. The optical absorption spectrum of 87 Rb D1 line and the microwave frequency correction signal are successfully observed while connecting the package with the servo circuit system. Using the above mentioned packaging solution, a CSAC with short-term frequency stability of about 7 × 10 −10 τ −1/2 has been successfully achieved, which demonstrates that this physics package would become one promising solution for the CSAC.
We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.
The authors have developed a Chip-Scale Atomic Clock (CSAC) of sufficiently low power and small size to enable atomic timing in portable battery-powered devices. The collaboration of diverse research teams in clock technology, micro-electromechanical systems (MEMS), and optoelectronic devices has resulted in size and power reduction of atomic clock technology by more than two orders of magnitude. In 2007, we completed a pre-production build and evaluation of ten identical CSACs, with power <125 mW and short-term stability of σ y (τ) < 2 × 10 -10 τ -1/2 1 . This paper reviews the physics and engineering considerations which underlie CSAC technology, describes in detail our CSAC implementation, and presents the results from the pre-production build.
We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.
Ever since the idea of the chip-scale atomic clock (CSAC) based on coherent population trapping (CPT) transition theory was proposed, the CSAC has been used widely in many various fields because of its characteristics of low power consumption, small size and good performance. It can be used in micro-positioning navigation and timing system, geophysical prospecting of the ocean bottom, and 5G communication system. Researchers work on reducing its volume and power consumption to make it more widely used. In the meantime, we all made great effort to improve its long-term stability. In this paper, we report our progress toward chip-scale atomic clock based on the87Rb CPT transition during 2019. We reduced the volume of the CSAC from 20 cm3to 12 cm3. For the physical part, we optimized the structure of the physical package to make sure it is possible for mass production. For the electrical part, we redesigned and rearranged the circuit, optimized the temperature control algorithm, employed a disciplining method. Finally, the frequency stability of CSAC was obtained to be 3.66×10-11, 6.39×10-12and 3.42 ×10-13at the interrogation time of 1 s, 103s and 104s respectively.