Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Improving the frequency stability of atomic frequency standard basing on the noise asynchromism correction

Qian Wang, Rong Wei, Richang Dong, Jinda Lin, Wenli Wang, Yuzhu Wang

Published Jul 1, 2017• 0 citations
Publisher

Abstract

We propose an improvement for increasing the performance of locked periodic atomic frequency standards(AFS), based on correcting the noise of the asynchronism of phase-detecting and feedback process. Theoretical analysis and numerical simulation show that the method can optimize the stability AFS which is related with d. And is the duty of phase-discriminating of AFS. If in-loop noise possesses white frequency noise characteristics, the stability will decrease following the coefficient of √(1 − d). Specially, when d approaches to 1, the stability will reach the limit of quantum project noise. Here we demonstrate three schemes to realize the idea in experiments and overlap-feedback is the most easily implemented one. Considering Dick effect in our method, the stability of our atomic fountain will be better than 1 × 10−14τ−1/2at d>0.93.

DOI
10.1109/fcs.2017.8088864

Related papers

Analytically exploiting noise correlations inside the feedback loop to improve locked-oscillator performance

Jarrah Sastrawan, C. Jones, Imraan Akhalwaya +2 more

We introduce concepts from optimal estimation to the stabilization of precision frequency standards limited by noisy local oscillators. We develop a theoretical framework casting various measures for frequency standard variance in terms of frequency-domain transfer functions, capturing the effects of feedback stabilization via a time series of Ramsey measurements. Using this framework, we introduce an optimized hybrid predictive feedforward measurement protocol that employs results from multiple past measurements and transfer-function-based calculations of measurement covariance to improve the accuracy of corrections within the feedback loop. In the presence of common non-Markovian noise processes these measurements will be correlated in a calculable manner, providing a means to capture the stochastic evolution of the local oscillator frequency during the measurement cycle. We present analytic calculations and numerical simulations of oscillator performance under competing feedback schemes and demonstrate benefits in both correction accuracy and long-term oscillator stability using hybrid feedforward. Simulations verify that in the presence of uncompensated dead time and noise with significant spectral weight near the inverse cycle time predictive feedforward outperforms traditional feedback, providing a path towards developing a class of stabilization software routines for frequency standards limited by noisy local oscillators.

arXiv:1407.3902•Physical review. E•Aug 8, 2016•7 citations

Dick effect in a pulsed atomic clock using coherent population trapping

Jean-Marie Danet, M. Lours, Stéphane Guérandel +1 more

The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here, we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Because of its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally, this study permitted the choice of an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2 x 10-13at 1 s.

arXiv:1406.6673•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Apr 1, 2014•66 citations

Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard

Giorgio Santarelli, Philippe Laurent, P. Lemonde +5 more

We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms ${N}_{\mathrm{at}}$. For ${N}_{\mathrm{at}}$ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.

Physical Review Letters•Jun 7, 1999•569 citations

Overcoming the quantum projection noise (QPN) limit without preparation of the spin-squeezed state

Nobuyasu Shiga, Makoto Takeuchi

Atomic clocks have reached the Quantum Projection Noise (QPN) limit of stability and it has been proposed to use the entangled atomic ensemble in order to overcome the QPN limit. We have proposed a new method to lock the phase of the Local Oscillator (LO) to the atomic phase and call, "atomic phase lock (APL)." This APL could possibly overcome the QPN limit without need of preparing the entangled atomic ensemble. Traditional Ramsey method destroys the coherence of the atomic spin due to the projection measurement at each cycle. This destruction and initialization of the phase at each cycle introduce additional noise and the performance of the atomic clock is limited at the white frequency noise level. APL employs dispersion measurements, i.e. Faraday rotation, in order to measure the phase difference without destroying the atomic phase. By repeating the measurement cycle with sufficiently small dead time, one can suppress the LO noise down to white phase noise level, achieving the τ-1 dependence of the Allan variance that can eventually overcome the QPN limit in long term. We are preparing a proof-of-principle experiment using the ensemble of trapped 171Yb+ ions with hyperfine splitting (12.6 GHz) as a clock transition and report the current status of the experiment as well.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•0 citations

The Dick effect for an optical frequency standard

Audrey Quessada, Richard P. Kovacich, I. Courtillot +3 more

We present an analysis of the frequency stability degradation of an optical atomic frequency standard which is operated sequentially, and that is caused by the frequency noise of the laser used to interrogate the clock transition. This is an extension to optical frequencies of the 'Dick effect' already studied in atomic microwave frequency standards. It is shown that the simple concept of laser linewidth is not the relevant parameter to estimate the frequency stability degradation. Rather, the details of the laser frequency noise spectral density must be accounted for together with the parameters of the interrogation method. We compute the optical Dick effect in the case of a four pulse Ramsey–Bordé interferometer. We show that it may be minimized by optimizing the time sequence so that only the Fourier frequencies with minimum laser noise are sampled. Finally, we evaluate the degradation which would be obtained with one of our lasers used as an interrogation oscillator. This laser reaches a white noise floor S ν ( f ) = 10 −2 Hz 2 /Hz at a Fourier frequency of 100 Hz. We show that with this particular laser, a relative frequency stability of the order of 10 −16 in a 1 s averaging time can be reached using realistic experimental parameters.

Journal of Optics B Quantum and Semiclassical Optics•Apr 1, 2003•107 citations

Leveraging correlated laser noise to improve optical frequency comparisons

Ethan Clements, M. Bohman, May E. Kim +14 more

Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations
We propose an improvement for increasing the performance of locked periodic atomic frequency standards(AFS), based on correcting the noise of the asynchronism of phase-detecting and feedback process. Theoretical analysis and numerical simulation show that the method can optimize the stability AFS which is related with d. And is the duty of phase-discriminating of AFS. If in-loop noise possesses white frequency noise characteristics, the stability will decrease following the coefficient of √(1 − d). Specially, when d approaches to 1, the stability will reach the limit of quantum project noise. Here we demonstrate three schemes to realize the idea in experiments and overlap-feedback is the most easily implemented one. Considering Dick effect in our method, the stability of our atomic fountain will be better than 1 × 10−14τ−1/2at d>0.93.
We introduce concepts from optimal estimation to the stabilization of precision frequency standards limited by noisy local oscillators. We develop a theoretical framework casting various measures for frequency standard variance in terms of frequency-domain transfer functions, capturing the effects of feedback stabilization via a time series of Ramsey measurements. Using this framework, we introduce an optimized hybrid predictive feedforward measurement protocol that employs results from multiple past measurements and transfer-function-based calculations of measurement covariance to improve the accuracy of corrections within the feedback loop. In the presence of common non-Markovian noise processes these measurements will be correlated in a calculable manner, providing a means to capture the stochastic evolution of the local oscillator frequency during the measurement cycle. We present analytic calculations and numerical simulations of oscillator performance under competing feedback schemes and demonstrate benefits in both correction accuracy and long-term oscillator stability using hybrid feedforward. Simulations verify that in the presence of uncompensated dead time and noise with significant spectral weight near the inverse cycle time predictive feedforward outperforms traditional feedback, providing a path towards developing a class of stabilization software routines for frequency standards limited by noisy local oscillators.
The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here, we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Because of its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally, this study permitted the choice of an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2 x 10-13at 1 s.
We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms Nat{N}_{\mathrm{at}}Nat​. For Nat{N}_{\mathrm{at}}Nat​ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.
Atomic clocks have reached the Quantum Projection Noise (QPN) limit of stability and it has been proposed to use the entangled atomic ensemble in order to overcome the QPN limit. We have proposed a new method to lock the phase of the Local Oscillator (LO) to the atomic phase and call, "atomic phase lock (APL)." This APL could possibly overcome the QPN limit without need of preparing the entangled atomic ensemble. Traditional Ramsey method destroys the coherence of the atomic spin due to the projection measurement at each cycle. This destruction and initialization of the phase at each cycle introduce additional noise and the performance of the atomic clock is limited at the white frequency noise level. APL employs dispersion measurements, i.e. Faraday rotation, in order to measure the phase difference without destroying the atomic phase. By repeating the measurement cycle with sufficiently small dead time, one can suppress the LO noise down to white phase noise level, achieving the τ-1 dependence of the Allan variance that can eventually overcome the QPN limit in long term. We are preparing a proof-of-principle experiment using the ensemble of trapped 171Yb+ ions with hyperfine splitting (12.6 GHz) as a clock transition and report the current status of the experiment as well.
We present an analysis of the frequency stability degradation of an optical atomic frequency standard which is operated sequentially, and that is caused by the frequency noise of the laser used to interrogate the clock transition. This is an extension to optical frequencies of the 'Dick effect' already studied in atomic microwave frequency standards. It is shown that the simple concept of laser linewidth is not the relevant parameter to estimate the frequency stability degradation. Rather, the details of the laser frequency noise spectral density must be accounted for together with the parameters of the interrogation method. We compute the optical Dick effect in the case of a four pulse Ramsey–Bordé interferometer. We show that it may be minimized by optimizing the time sequence so that only the Fourier frequencies with minimum laser noise are sampled. Finally, we evaluate the degradation which would be obtained with one of our lasers used as an interrogation oscillator. This laser reaches a white noise floor S ν ( f ) = 10 −2 Hz 2 /Hz at a Fourier frequency of 100 Hz. We show that with this particular laser, a relative frequency stability of the order of 10 −16 in a 1 s averaging time can be reached using realistic experimental parameters.
Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.