Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1406.6673 · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control

Dick effect in a pulsed atomic clock using coherent population trapping

Jean-Marie Danet, M. Lours, Stéphane Guérandel, Emeric de Clercq

Published Apr 1, 2014• 66 citations
arXivHTMLPDF

Abstract

The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here, we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Because of its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally, this study permitted the choice of an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2 x 10-13at 1 s.

DOI
10.1109/tuffc.2014.2945

Related papers

Reduction of dick effect in a pulsed CPT vapor cell clock by interleaving lock

Xiaolin Sun, Pengfei Cheng, Yani Zuo +3 more

The Dick effect is one of the main limits for a passive atomic frequency standard to reach its frequency instability limit due to quantum projection noise. In this paper, we report on the reduction of Dick effect of a Ramsey-CPT vapor cell clock using interleaving lock. Three parameters are investigated in the process of optimizing sensitivity function in details. By optimizing the sensitivity function, the Dick effect induced Allan deviation (DEAD) can be reduced to the level of 10-14.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

Ramsey-CPT spectroscopy for a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly +3 more

We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks

•Jul 7, 2021•0 citations

Two-step pulse observation for Raman–Ramsey coherent population trapping atomic clocks

Yuichiro Yano, Shigeyoshi Goka, Masatoshi Kajita

We propose a two-step pulse observation method to enhance the frequency stability of coherent population trapping (CPT) atomic clocks. The proposed method is a Raman–Ramsey scheme with low light intensity at resonance observation and provides a Ramsey-CPT resonance with both reduced frequency sensitivity to the light intensity and a high signal-to-noise ratio by reducing the repumping into a steady dark state. The resonance characteristics were calculated using density matrix analysis of a Λ-type three-level system that was modeled on the 133 Cs D 1 line, and the characteristics were also measured using a vertical-cavity surface-emitting laser and a Cs vapor cell.

arXiv:1411.3779•Applied Physics Express•Dec 11, 2014•9 citations

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•89 citations

Frequency biases in a cold-atom coherent population trapping clock

Elizabeth A. Donley, E. Blanshan, François-Xavier Esnault +1 more

A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•2 citations

Exploring the Use of Ramsey-CPT Spectroscopy for a Microcell-Based Atomic Clock

Clément Carlé, Michael Petersen, Nicolas Passilly +3 more

We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and$450~\mu \text{s}$, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of$450~\mu \text{s}$, a clock fractional frequency stability of$3.8 \times 10^{-12}$at 104s is obtained, in comparison with the level of$8\times 10^{-11}$obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jun 2, 2021•18 citations
The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here, we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Because of its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally, this study permitted the choice of an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2 x 10-13at 1 s.
We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks
We propose a two-step pulse observation method to enhance the frequency stability of coherent population trapping (CPT) atomic clocks. The proposed method is a Raman–Ramsey scheme with low light intensity at resonance observation and provides a Ramsey-CPT resonance with both reduced frequency sensitivity to the light intensity and a high signal-to-noise ratio by reducing the repumping into a steady dark state. The resonance characteristics were calculated using density matrix analysis of a Λ-type three-level system that was modeled on the 133 Cs D 1 line, and the characteristics were also measured using a vertical-cavity surface-emitting laser and a Cs vapor cell.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.
We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and450 μs450~\mu \text{s}450 μs, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of450 μs450~\mu \text{s}450 μs, a clock fractional frequency stability of3.8×10−123.8 \times 10^{-12}3.8×10−12at 104s is obtained, in comparison with the level of8×10−118\times 10^{-11}8×10−11obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.