Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard

Giorgio Santarelli, Philippe Laurent, P. Lemonde, Andr  Clairon, Anthony G. Mann, Sheng Chang, Andre Nicholas Luiten, Ch Salomon

Published Jun 7, 1999• 569 citations
Publisher

Abstract

We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms ${N}_{\mathrm{at}}$. For ${N}_{\mathrm{at}}$ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.

DOI
10.1103/physrevlett.82.4619

Related papers

Reaching the quantum limit in a fountain clock using a microwave oscillator phase locked to an ultrastable laser

S. Weyers, B. Lipphardt, H. Schnatz

A cesium fountain clock is operated utilizing a microwave oscillator that derives its frequency stability from a stable laser by means of a fiber-laser femtosecond frequency comb. This oscillator is based on the technology developed for optical clocks and replaces the quartz-based microwave oscillator commonly used in fountain clocks. As a result, a significant decrease in the frequency instability of the fountain clock is obtained, reaching $7.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{[\ensuremath{\tau}\text{ }(\text{s})]}^{\ensuremath{-}1/2}$. We could demonstrate that for a significant range of detected atom numbers the instability is limited by quantum projection noise only, and that for the current status of this fountain clock the microwave source poses no limit on the achievable frequency instability.

arXiv:0901.2788•Physical Review A•Mar 11, 2009•84 citations

Optical Spectrum Analyzer with Quantum-Limited Noise Floor

Michael Bishof, Xiaogang Zhang, Michael J. Martin +1 more

Interactions between atoms and lasers provide the potential for unprecedented control of quantum states. Fulfilling this potential requires detailed knowledge of frequency noise in optical oscillators with state-of-the-art stability. We demonstrate a technique that precisely measures the noise spectrum of an ultrastable laser using optical lattice-trapped 87Sr atoms as a quantum projection noise-limited reference. We determine the laser noise spectrum from near dc to 100 Hz via the measured fluctuations in atomic excitation, guided by a simple and robust theory model. The noise spectrum yields a 26(4) mHz linewidth at a central frequency of 429 THz, corresponding to an optical quality factor of 1.6×10(16). This approach improves upon optical heterodyne beats between two similar laser systems by providing information unique to a single laser and complements the traditionally used Allan deviation which evaluates laser performance at relatively long time scales. We use this technique to verify the reduction of resonant noise in our ultrastable laser via feedback from an optical heterodyne beat. Finally, we show that knowledge of our laser's spectrum allows us to accurately predict the laser-limited stability for optical atomic clocks.

arXiv:1303.6741•Physical Review Letters•Aug 30, 2013•84 citations

Article

Marie-Claude Gagné, J.-S. Boulanger, R.J. Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Jan 1, 1998•1 citation

Loading a fountain clock with an enhanced low-velocity intense source of atoms

G. Dobrev, Vladislav P. Gerginov, S. Weyers

We present experimental work for improved atom loading in the optical molasses of a cesium fountain clock, employing a low-velocity intense source of atoms [Lu et al., Phys. Rev. Lett 77, 3331 (1996)], which we modify by adding a dark-state pump laser. With this modification the atom source has a mean flux of $4\ifmmode\times\else\texttimes\fi{}{10}^{8}$ atoms/s at a mean atom velocity of $8.6$ m/s. Compared to fountain operation using background gas loading, we achieve a significant increase of the loaded and detected atom number by a factor of 40. Operating the fountain clock with a total number of detected atoms ${N}_{\mathrm{at}}=2.9\ifmmode\times\else\texttimes\fi{}{10}^{6}$ in the quantum projection noise-limited regime, a frequency instability ${\ensuremath{\sigma}}_{y}(1s)=2.7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ is demonstrated.

arXiv:1601.04852•Physical Review A•Apr 27, 2016•7 citations

Operating Atomic Fountain Clock Using Robust DBR Laser: Short-Term Stability Analysis

Sangmin Lee, Myoung-Sun Heo, Taeg Yong Kwon +6 more

We report on a robust distributed Bragg reflector (DBR) laser system for an atomic fountain clock. To confirm the performance of a DBR laser, the short-term stability of an atomic fountain clock, KRISS-F1, is measured with both DBR laser and an extended-cavity diode laser (ECDL) as a master laser in the fountain laser system. The short-term stability of the fountain clock due to the laser noise is determined to be σy(τ = Tc) = 1.4×10-14when either the ECDL or the DBR laser is used as a master laser. The total stability of the fountain clock with the DBR laser is limited to 3.5 × 10-14at 1 s of averaging time and at the highest atom number in the experiment, which is limited by quantum projection noise. No additional degradation in fountain performance is observed when an ECDL is replaced by the DBR laser. From these results, we conclude that our fountain clock is made much more robust by adopting a DBR laser, which is immune to acoustic and vibrational shocks as well as environmental temperature variations.

IEEE Transactions on Instrumentation and Measurement•Jan 2, 2017•15 citations

A laser-cooled atomic probe for low variations of static magnetic fields.

S. Ghezali, Andr  Clairon

Neutral atom trapping and laser cooling has opened the way to large prospects for the present generation of atomic frequency standards [1].A cold cesium fountain device has been built for the first time at the Observatoire de Paris and is now operating since 1994.Its frequency stability, 4 10 -14  -1/2 where  is the integration time, has been the best one ever measured for a while.This letter shows how accurate can be the measurement of low static magnetic fields within the fountain device and the variations along the longitudinal and transverse axis.Thus the device is no more operating as a clock but constitutes a very precise magnetometer.

IOSR Journal of Applied Physics•Apr 1, 2016•0 citations
We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms Nat{N}_{\mathrm{at}}Nat​. For Nat{N}_{\mathrm{at}}Nat​ varying from 4\ifmmode×\else\texttimes\fi1044\ifmmode\times\else\texttimes\fi{}{10}^{4}4\ifmmode×\else\texttimes\fi104 to 6\ifmmode×\else\texttimes\fi1056\ifmmode\times\else\texttimes\fi{}{10}^{5}6\ifmmode×\else\texttimes\fi105 the Allan standard deviation of the frequency fluctuations is in excellent agreement with the Nat\ensuremath−1/2{N}_{\mathrm{at}}^{\ensuremath{-}1/2}Nat\ensuremath−1/2​ law of atomic projection noise. With 6\ifmmode×\else\texttimes\fi1056\ifmmode\times\else\texttimes\fi{}{10}^{5}6\ifmmode×\else\texttimes\fi105 atoms, the relative frequency stability is 4\ifmmode×\else\texttimes\fi10\ensuremath−14\ensuremathτ\ensuremath−1/24\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}4\ifmmode×\else\texttimes\fi10\ensuremath−14\ensuremathτ\ensuremath−1/2, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.
A cesium fountain clock is operated utilizing a microwave oscillator that derives its frequency stability from a stable laser by means of a fiber-laser femtosecond frequency comb. This oscillator is based on the technology developed for optical clocks and replaces the quartz-based microwave oscillator commonly used in fountain clocks. As a result, a significant decrease in the frequency instability of the fountain clock is obtained, reaching $7.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{[\ensuremath{\tau}\text{ }(\text{s})]}^{\ensuremath{-}1/2}$. We could demonstrate that for a significant range of detected atom numbers the instability is limited by quantum projection noise only, and that for the current status of this fountain clock the microwave source poses no limit on the achievable frequency instability.
Interactions between atoms and lasers provide the potential for unprecedented control of quantum states. Fulfilling this potential requires detailed knowledge of frequency noise in optical oscillators with state-of-the-art stability. We demonstrate a technique that precisely measures the noise spectrum of an ultrastable laser using optical lattice-trapped 87Sr atoms as a quantum projection noise-limited reference. We determine the laser noise spectrum from near dc to 100 Hz via the measured fluctuations in atomic excitation, guided by a simple and robust theory model. The noise spectrum yields a 26(4) mHz linewidth at a central frequency of 429 THz, corresponding to an optical quality factor of 1.6×10(16). This approach improves upon optical heterodyne beats between two similar laser systems by providing information unique to a single laser and complements the traditionally used Allan deviation which evaluates laser performance at relatively long time scales. We use this technique to verify the reduction of resonant noise in our ultrastable laser via feedback from an optical heterodyne beat. Finally, we show that knowledge of our laser's spectrum allows us to accurately predict the laser-limited stability for optical atomic clocks.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P
We present experimental work for improved atom loading in the optical molasses of a cesium fountain clock, employing a low-velocity intense source of atoms [Lu et al., Phys. Rev. Lett 77, 3331 (1996)], which we modify by adding a dark-state pump laser. With this modification the atom source has a mean flux of $4\ifmmode\times\else\texttimes\fi{}{10}^{8}$ atoms/s at a mean atom velocity of 8.68.68.6 m/s. Compared to fountain operation using background gas loading, we achieve a significant increase of the loaded and detected atom number by a factor of 40. Operating the fountain clock with a total number of detected atoms ${N}_{\mathrm{at}}=2.9\ifmmode\times\else\texttimes\fi{}{10}^{6}$ in the quantum projection noise-limited regime, a frequency instability ${\ensuremath{\sigma}}_{y}(1s)=2.7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ is demonstrated.
We report on a robust distributed Bragg reflector (DBR) laser system for an atomic fountain clock. To confirm the performance of a DBR laser, the short-term stability of an atomic fountain clock, KRISS-F1, is measured with both DBR laser and an extended-cavity diode laser (ECDL) as a master laser in the fountain laser system. The short-term stability of the fountain clock due to the laser noise is determined to be σy(τ = Tc) = 1.4×10-14when either the ECDL or the DBR laser is used as a master laser. The total stability of the fountain clock with the DBR laser is limited to 3.5 × 10-14at 1 s of averaging time and at the highest atom number in the experiment, which is limited by quantum projection noise. No additional degradation in fountain performance is observed when an ECDL is replaced by the DBR laser. From these results, we conclude that our fountain clock is made much more robust by adopting a DBR laser, which is immune to acoustic and vibrational shocks as well as environmental temperature variations.
Neutral atom trapping and laser cooling has opened the way to large prospects for the present generation of atomic frequency standards [1].A cold cesium fountain device has been built for the first time at the Observatoire de Paris and is now operating since 1994.Its frequency stability, 4 10 -14  -1/2 where  is the integration time, has been the best one ever measured for a while.This letter shows how accurate can be the measurement of low static magnetic fields within the fountain device and the variations along the longitudinal and transverse axis.Thus the device is no more operating as a clock but constitutes a very precise magnetometer.