Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Superconductor Science and Technology

Dispersive nanoSQUID magnetometry

Eli M. Levenson-Falk, Natania Antler, Irfan A. Siddiqi

Published Sep 26, 2016• 19 citations
Publisher

Abstract

Abstract We describe the theory and implementation of a dispersive magnetometer based on an aluminum nanoSQUID. The nanoSQUID consists of a superconducting loop interrupted by two variable-thickness weak-link nanobridge Josephson junctions. When the nanoSQUID is placed in parallel with a lumped-element capacitor, it acts as the inductive element in a resonant tank circuit. By performing microwave reflectometry on the circuit, the SQUID inductance can be measured, providing a sensitive meter of the flux threading the SQUID loop. In this review we provide the theoretical basis for the device, describe design and operation considerations, and present characterization results on several devices.

DOI
10.1088/0953-2048/29/11/113003

Related papers

A dispersive nanoSQUID magnetometer for ultra-low noise, high bandwidth flux detection

Eli M. Levenson-Falk, Rajamani Vijay, Natania Antler +1 more

We describe a dispersive nanoSQUID (nanoscale superconducting quantum interference device) magnetometer comprised of two variable thickness aluminum weak-link Josephson junctions shunted in parallel with an on-chip capacitor. This arrangement forms a nonlinear oscillator with a tunable 4–8 GHz resonant frequency with a quality factor Q = 30 when coupled directly to a 50 Ω transmission line. In the presence of a near-resonant microwave carrier signal, a low frequency flux input generates sidebands that are readily detected using microwave reflectometry. If the carrier excitation is sufficiently strong, then the magnetometer also exhibits parametric gain, resulting in a minimum effective flux noise of 30 n Φ 0 Hz −1/2 with 20 MHz of instantaneous bandwidth. If the magnetometer is followed with a near-quantum-noise-limited Josephson parametric amplifier, we can increase the bandwidth to 60 MHz without compromising sensitivity. This combination of high sensitivity and wide bandwidth with no on-chip dissipation makes this device ideal for local sensing of spin dynamics, both classical and quantum.

arXiv:1301.3184•Superconductor Science and Technology•Apr 4, 2013•41 citations

Static and Microwave Transport Properties of Aluminum Nanobridge Josephson Junctions

Eli M. Levenson-Falk

Josephson junctions are the basis of superconducting qubits, amplifiers, and magnetometers. Historically, tunnel-style junctions have been most common. However, for some applications--those requiring a small, highly transparent, all-superconducting junction--nanobridge weak link junctions may be preferable. This thesis presents extensive characterization of aluminum nanobridge Josephson junctions. The junction behavior is simulated by numerically solving the Usadel equations. These simulations are then tested and confirmed via low- and microwave-frequency transport measurements. The data confirm that nanobridge junctions approach the ideal weak-link Josephson limit.Such a near-ideal junction can be used in a superconducting quantum interference device (SQUID) to form an ultra sensitive magnetometer. This thesis presents the first nanobridge-based dispersive SQUID magnetometer. The devices show near-zero dissipation, with bandwidth and sensitivity on par with the best reported results for any SQUID-based magnetometer. These magnetometers have several flexible modes of operation, allowing for optimization of sensitivity, bandwidth, or backaction. They also provide insight into the internal dynamics of dispersive measurement with nonlinear cavities, as the magnetometer backaction depends on the bias point and can readily be measured.Nanobridge junctions also provide a useful tool for diagnosing sources of decoherence in superconducting qubits. By replacing the usual tunnel junction with a nanobridge, the contribution of the junction to decoherence processes may be probed. In particular, the interaction of nanobridge junctions with quasiparticles provides information both about the junctions themselves and about quasiparticle generation and relaxation mechanisms. This thesis reports measurements of nonequilibrium quasiparticles trapping in phase-biased nanobridge junctions. By probing the quasiparticle-induced changes in resonant frequency of a high-Q nanoSQUID oscillator, one may measure the mean distribution of trapped quasiparticles and study its temperature dependence. These measurements also provide spectroscopy of the junctions' internal Andreev states and the dynamics of quasiparticle excitation and retrapping. The work presented here demonstrates the utility of nanobridge junctions as a tool for quantifying the population and distribution of quasiparticles in a superconducting circuit.

•Jan 1, 2013•1 citation

Dispersive magnetometry with a quantum limited SQUID parametric amplifier

Michael J. Hatridge, Rajamani Vijay, D. H. Slichter +2 more

There is currently fundamental and technological interest in measuring and manipulating nanoscale magnets, particularly in the quantum coherent regime. To observe the dynamics of such systems one requires a magnetometer with not only exceptional sensitivity but also high gain, wide bandwidth, and low backaction. We demonstrate a dispersive magnetometer consisting of a two-junction superconducting quantum interference device (SQUID) in parallel with an integrated, lumped-element capacitor. Input flux signals are encoded as a phase modulation of the microwave drive tone applied to the magnetometer, resulting in a single quadrature voltage signal. For strong drive power, the nonlinearity of the resonator results in quantum limited, phase sensitive parametric amplification of this signal, which improves flux sensitivity at the expense of bandwidth. Depending on the drive parameters, the device performance ranges from an effective flux noise of 0.29 $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}$Hz${}^{\ensuremath{-}1/2}$ and 20 MHz of signal bandwidth to a noise of 0.14 $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}$Hz${}^{\ensuremath{-}1/2}$ and a bandwidth of 0.6 MHz. These results are in excellent agreement with our theoretical model.

arXiv:1003.2466•Physical Review B•Apr 4, 2011•270 citations

Nanobridge superconducting quantum interference devices: Beyond the Josephson limit

Dibyendu Hazra

Nanoscale superconducting quantum interference devices (nano-SQUIDS) where the weak links are made from nanobridges, i.e., nanobridge SQUIDs (NBSs), are one of the most sensitive magnetometers for nanoscale magnetometry. Because of very strong nonlinearity in the nanobridge-electrode joints, the applied magnetic flux (${\mathrm{\ensuremath{\Phi}}}_{a}$)--critical current (${I}_{c}$) characteristics of NBSs differ very significantly from conventional tunnel-junction SQUIDs, especially when the nanobridges are long and/or the screening parameter is large. However, in most of the theoretical descriptions, NBSs have been treated as the conventional tunnel-junction SQUIDs, which are based on the dc Josephson effect. Here, I present a model demonstrating that for long nanobridges and/or large screening parameters the ${I}_{c}({\mathrm{\ensuremath{\Phi}}}_{a})$ of a NBS can be explained by merely considering the fluxoid quantization in the NBS loop and the energy of the NBS; it is not necessary to take the Josephson effect into consideration. I also demonstrate that using the model, one can derive useful expressions such as the modulation depth and transfer function. I discuss the role of the kinetic inductance fraction ($\ensuremath{\kappa}$) in determining ${I}_{c}({\mathrm{\ensuremath{\Phi}}}_{a})$. I compare the predictions of the present model with the experimental data already published by several groups.

arXiv:1809.09510•Physical review. B./Physical review. B•Apr 5, 2019•11 citations

In-plane magnetic field tolerance of a dispersive aluminum nanobridge SQUID magnetometer

N. Antler, Eli M. Levenson-Falk, R. Naik +4 more

We characterize the flux sensitivity of a dispersive 3D aluminum nanobridge superconducting quantum interference device (SQUID) magnetometer as a function of applied in-plane magnetic field. In zero field, we observe an effective flux noise of 17 nΦ0/Hz1/2 with 25 MHz of bandwidth at 150 mK. Flux noise increased by less than a factor of three with parallel magnetic fields up to 61 mT. Operation in higher fields may be possible by decreasing the dimensions of the shunt capacitor in the magnetometer circuit. These devices are thus well suited for observing high-speed dynamics in nanoscale magnets, even in the presence of moderate bias magnetic fields.

arXiv:1303.2737•Applied Physics Letters•Jun 10, 2013•19 citations

NanoSQUIDs for millikelvin magnetometry

A. Blois

Nanoscale Superconducting QUantum Interference Devices (SQUIDs) have spin sensitivities approaching that required to detect the flip of a single spin in close proximity. There is considerable interest in developing them for measuring the properties of small spin populations in magnetic systems. It is desirable that such measurements can be realised at sub-kelvin temperatures thereby allowing the study of magnetic systems that undergo phase changes at such temperatures. However, most nanoscale SQUIDs use nanobridges as the Josephson elements which limits the operating range to temperatures close to the transition temperature of the device. Well below this, the current-phase relation can become non-sinusoidal, and hot spots arising from the large critical current lead to hysteretic I-V characteristics. To extend the temperature range downwards, we have developed a range of nanoSQUIDs fabricated from alternative materials with lower transition temperatures including Ti/Au and Al/Ag bilayers patterned using lift-off and e-beam lithography (EBL). We report on their I-V characteristics, noise performance and behaviour in applied magnetic fields at temperatures down to 60 mK. We discuss theoretical analysis and computer modelling of the heat flow in the nanobridge structure, and consider the effects of bank geometry and kinetic inductance on the overall device performance. Finally, we present measurements of several magnetic systems: control lines, superconducting islands and ground planes and discuss the feasibility of magnetic measurements of novel materials of interest, including the heterointerface between lanthanium aluminate and strontium titanate.

•Apr 28, 2014•0 citations
Abstract We describe the theory and implementation of a dispersive magnetometer based on an aluminum nanoSQUID. The nanoSQUID consists of a superconducting loop interrupted by two variable-thickness weak-link nanobridge Josephson junctions. When the nanoSQUID is placed in parallel with a lumped-element capacitor, it acts as the inductive element in a resonant tank circuit. By performing microwave reflectometry on the circuit, the SQUID inductance can be measured, providing a sensitive meter of the flux threading the SQUID loop. In this review we provide the theoretical basis for the device, describe design and operation considerations, and present characterization results on several devices.
We describe a dispersive nanoSQUID (nanoscale superconducting quantum interference device) magnetometer comprised of two variable thickness aluminum weak-link Josephson junctions shunted in parallel with an on-chip capacitor. This arrangement forms a nonlinear oscillator with a tunable 4–8 GHz resonant frequency with a quality factor Q = 30 when coupled directly to a 50 Ω transmission line. In the presence of a near-resonant microwave carrier signal, a low frequency flux input generates sidebands that are readily detected using microwave reflectometry. If the carrier excitation is sufficiently strong, then the magnetometer also exhibits parametric gain, resulting in a minimum effective flux noise of 30 n Φ 0 Hz −1/2 with 20 MHz of instantaneous bandwidth. If the magnetometer is followed with a near-quantum-noise-limited Josephson parametric amplifier, we can increase the bandwidth to 60 MHz without compromising sensitivity. This combination of high sensitivity and wide bandwidth with no on-chip dissipation makes this device ideal for local sensing of spin dynamics, both classical and quantum.
Josephson junctions are the basis of superconducting qubits, amplifiers, and magnetometers. Historically, tunnel-style junctions have been most common. However, for some applications--those requiring a small, highly transparent, all-superconducting junction--nanobridge weak link junctions may be preferable. This thesis presents extensive characterization of aluminum nanobridge Josephson junctions. The junction behavior is simulated by numerically solving the Usadel equations. These simulations are then tested and confirmed via low- and microwave-frequency transport measurements. The data confirm that nanobridge junctions approach the ideal weak-link Josephson limit.Such a near-ideal junction can be used in a superconducting quantum interference device (SQUID) to form an ultra sensitive magnetometer. This thesis presents the first nanobridge-based dispersive SQUID magnetometer. The devices show near-zero dissipation, with bandwidth and sensitivity on par with the best reported results for any SQUID-based magnetometer. These magnetometers have several flexible modes of operation, allowing for optimization of sensitivity, bandwidth, or backaction. They also provide insight into the internal dynamics of dispersive measurement with nonlinear cavities, as the magnetometer backaction depends on the bias point and can readily be measured.Nanobridge junctions also provide a useful tool for diagnosing sources of decoherence in superconducting qubits. By replacing the usual tunnel junction with a nanobridge, the contribution of the junction to decoherence processes may be probed. In particular, the interaction of nanobridge junctions with quasiparticles provides information both about the junctions themselves and about quasiparticle generation and relaxation mechanisms. This thesis reports measurements of nonequilibrium quasiparticles trapping in phase-biased nanobridge junctions. By probing the quasiparticle-induced changes in resonant frequency of a high-Q nanoSQUID oscillator, one may measure the mean distribution of trapped quasiparticles and study its temperature dependence. These measurements also provide spectroscopy of the junctions' internal Andreev states and the dynamics of quasiparticle excitation and retrapping. The work presented here demonstrates the utility of nanobridge junctions as a tool for quantifying the population and distribution of quasiparticles in a superconducting circuit.
There is currently fundamental and technological interest in measuring and manipulating nanoscale magnets, particularly in the quantum coherent regime. To observe the dynamics of such systems one requires a magnetometer with not only exceptional sensitivity but also high gain, wide bandwidth, and low backaction. We demonstrate a dispersive magnetometer consisting of a two-junction superconducting quantum interference device (SQUID) in parallel with an integrated, lumped-element capacitor. Input flux signals are encoded as a phase modulation of the microwave drive tone applied to the magnetometer, resulting in a single quadrature voltage signal. For strong drive power, the nonlinearity of the resonator results in quantum limited, phase sensitive parametric amplification of this signal, which improves flux sensitivity at the expense of bandwidth. Depending on the drive parameters, the device performance ranges from an effective flux noise of 0.29 $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}$Hz${}^{\ensuremath{-}1/2}$ and 20 MHz of signal bandwidth to a noise of 0.14 $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}$Hz${}^{\ensuremath{-}1/2}$ and a bandwidth of 0.6 MHz. These results are in excellent agreement with our theoretical model.
Nanoscale superconducting quantum interference devices (nano-SQUIDS) where the weak links are made from nanobridges, i.e., nanobridge SQUIDs (NBSs), are one of the most sensitive magnetometers for nanoscale magnetometry. Because of very strong nonlinearity in the nanobridge-electrode joints, the applied magnetic flux (${\mathrm{\ensuremath{\Phi}}}_{a}$)--critical current (Ic{I}_{c}Ic​) characteristics of NBSs differ very significantly from conventional tunnel-junction SQUIDs, especially when the nanobridges are long and/or the screening parameter is large. However, in most of the theoretical descriptions, NBSs have been treated as the conventional tunnel-junction SQUIDs, which are based on the dc Josephson effect. Here, I present a model demonstrating that for long nanobridges and/or large screening parameters the ${I}_{c}({\mathrm{\ensuremath{\Phi}}}_{a})$ of a NBS can be explained by merely considering the fluxoid quantization in the NBS loop and the energy of the NBS; it is not necessary to take the Josephson effect into consideration. I also demonstrate that using the model, one can derive useful expressions such as the modulation depth and transfer function. I discuss the role of the kinetic inductance fraction ($\ensuremath{\kappa}$) in determining ${I}_{c}({\mathrm{\ensuremath{\Phi}}}_{a})$. I compare the predictions of the present model with the experimental data already published by several groups.
We characterize the flux sensitivity of a dispersive 3D aluminum nanobridge superconducting quantum interference device (SQUID) magnetometer as a function of applied in-plane magnetic field. In zero field, we observe an effective flux noise of 17 nΦ0/Hz1/2 with 25 MHz of bandwidth at 150 mK. Flux noise increased by less than a factor of three with parallel magnetic fields up to 61 mT. Operation in higher fields may be possible by decreasing the dimensions of the shunt capacitor in the magnetometer circuit. These devices are thus well suited for observing high-speed dynamics in nanoscale magnets, even in the presence of moderate bias magnetic fields.
Nanoscale Superconducting QUantum Interference Devices (SQUIDs) have spin sensitivities approaching that required to detect the flip of a single spin in close proximity. There is considerable interest in developing them for measuring the properties of small spin populations in magnetic systems. It is desirable that such measurements can be realised at sub-kelvin temperatures thereby allowing the study of magnetic systems that undergo phase changes at such temperatures. However, most nanoscale SQUIDs use nanobridges as the Josephson elements which limits the operating range to temperatures close to the transition temperature of the device. Well below this, the current-phase relation can become non-sinusoidal, and hot spots arising from the large critical current lead to hysteretic I-V characteristics. To extend the temperature range downwards, we have developed a range of nanoSQUIDs fabricated from alternative materials with lower transition temperatures including Ti/Au and Al/Ag bilayers patterned using lift-off and e-beam lithography (EBL). We report on their I-V characteristics, noise performance and behaviour in applied magnetic fields at temperatures down to 60 mK. We discuss theoretical analysis and computer modelling of the heat flow in the nanobridge structure, and consider the effects of bank geometry and kinetic inductance on the overall device performance. Finally, we present measurements of several magnetic systems: control lines, superconducting islands and ground planes and discuss the feasibility of magnetic measurements of novel materials of interest, including the heterointerface between lanthanium aluminate and strontium titanate.