Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1303.2737 · Applied Physics Letters

In-plane magnetic field tolerance of a dispersive aluminum nanobridge SQUID magnetometer

N. Antler, Eli M. Levenson-Falk, R. Naik, Y.-D. Sun, A. Narla, R. Vijay, I. Siddiqi

Published Jun 10, 2013• 19 citations
arXivHTMLPDF

Abstract

We characterize the flux sensitivity of a dispersive 3D aluminum nanobridge superconducting quantum interference device (SQUID) magnetometer as a function of applied in-plane magnetic field. In zero field, we observe an effective flux noise of 17 nΦ0/Hz1/2 with 25 MHz of bandwidth at 150 mK. Flux noise increased by less than a factor of three with parallel magnetic fields up to 61 mT. Operation in higher fields may be possible by decreasing the dimensions of the shunt capacitor in the magnetometer circuit. These devices are thus well suited for observing high-speed dynamics in nanoscale magnets, even in the presence of moderate bias magnetic fields.

DOI
10.1063/1.4809782

Related papers

Superconducting Nanobridge SQUID Magnetometers for Spin Sensing

Natania Antler

Author(s): Antler, Natania | Advisor(s): Siddiqi, Irfan | Abstract: As the cutting edge of science and technology pushes towards smaller length scales, sensing technologies with nanoscale precision become increasingly important. In this thesis I will discuss the optimization and application of a 3D nanobridge SQUID magnetometer for studying solid state spin systems, in particular for sensing impurity spins in diamond. Solid state spins have proposed applications in memory and computation for both classical and quantum computing. Isolated spins typically have longer coherence times, making them attractive qubit candidates, but necessitating the development of very sensitive detectors for readout. This 3D nanobridge SQUID combines the exquisite spatial sensitivity of a traditional nanoSQUID with a large non-linearity on par with a tunnel junction SQUID. This allows us to build a highly sensitive magnetometer which can act as both an efficient flux transducer as well as a nearly quantum limited lumped Josephson Parametric Amplifier. We show that the device has a minimum flux noise of 17 ± 0.9 nΦ0/Hz1/2 with only a factor of ∼2.5 increase in flux noise up to 61 mT. A second generation device with a smaller capacitor achieves field tolerance up to 75 mT. The maximal bandwidth values range from 25-40 MHz in the parametric amplification regime to 70 MHz in the linear regime. This combination of large bandwidth, low flux noise, large flux coupling and field tolerance make this sensor a promising candidate for near-single-spin dynamics measurements.In the last part of this thesis we begin to demonstrate the utility of a nanobridge SQUID magnetometer for characterizing spin systems in the solid state. We use the magnetometer to measure the decay characteristics of P1 centers in diamond. We find that the spin-lattice relaxation time varies with temperature, with an order of magnitude decrease in the decay time between 25 mK and 370 mK.

•Jan 1, 2014•0 citations

A dispersive nanoSQUID magnetometer for ultra-low noise, high bandwidth flux detection

Eli M. Levenson-Falk, Rajamani Vijay, Natania Antler +1 more

We describe a dispersive nanoSQUID (nanoscale superconducting quantum interference device) magnetometer comprised of two variable thickness aluminum weak-link Josephson junctions shunted in parallel with an on-chip capacitor. This arrangement forms a nonlinear oscillator with a tunable 4–8 GHz resonant frequency with a quality factor Q = 30 when coupled directly to a 50 Ω transmission line. In the presence of a near-resonant microwave carrier signal, a low frequency flux input generates sidebands that are readily detected using microwave reflectometry. If the carrier excitation is sufficiently strong, then the magnetometer also exhibits parametric gain, resulting in a minimum effective flux noise of 30 n Φ 0 Hz −1/2 with 20 MHz of instantaneous bandwidth. If the magnetometer is followed with a near-quantum-noise-limited Josephson parametric amplifier, we can increase the bandwidth to 60 MHz without compromising sensitivity. This combination of high sensitivity and wide bandwidth with no on-chip dissipation makes this device ideal for local sensing of spin dynamics, both classical and quantum.

arXiv:1301.3184•Superconductor Science and Technology•Apr 4, 2013•41 citations

Dispersive magnetometry with a quantum limited SQUID parametric amplifier

Michael J. Hatridge, Rajamani Vijay, D. H. Slichter +2 more

There is currently fundamental and technological interest in measuring and manipulating nanoscale magnets, particularly in the quantum coherent regime. To observe the dynamics of such systems one requires a magnetometer with not only exceptional sensitivity but also high gain, wide bandwidth, and low backaction. We demonstrate a dispersive magnetometer consisting of a two-junction superconducting quantum interference device (SQUID) in parallel with an integrated, lumped-element capacitor. Input flux signals are encoded as a phase modulation of the microwave drive tone applied to the magnetometer, resulting in a single quadrature voltage signal. For strong drive power, the nonlinearity of the resonator results in quantum limited, phase sensitive parametric amplification of this signal, which improves flux sensitivity at the expense of bandwidth. Depending on the drive parameters, the device performance ranges from an effective flux noise of 0.29 $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}$Hz${}^{\ensuremath{-}1/2}$ and 20 MHz of signal bandwidth to a noise of 0.14 $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}$Hz${}^{\ensuremath{-}1/2}$ and a bandwidth of 0.6 MHz. These results are in excellent agreement with our theoretical model.

arXiv:1003.2466•Physical Review B•Apr 4, 2011•270 citations

A High-Performance Nb Nano-Superconducting Quantum Interference Device with a Three-Dimensional Structure

Lei Chen, Hao Wang, Xiaoyu Liu +2 more

A superconducting quantum interference device (SQUID) miniaturized into the nanoscale is promising in the inductive detection of a single electron spin. A nano-SQUID with a strong spin coupling coefficient, a low flux noise, and a wide working magnetic field range is highly desired in a single spin resonance measurement. Nano-SQUIDs with Dayem bridge junctions excel in a high working field range and in the direct coupling from spins to the bridge. However, the common planar structure of nano-SQUIDs is known for problems such as a shallow flux modulation depth and a troublesome hysteresis in current–voltage curves. Here, we developed a fabrication process for creating three-dimensional (3-D) niobium (Nb) nano-SQUIDs with nanobridge junctions that can be tuned independently. Characterization of the device shows up to 45.9% modulation depth with a reversible current–voltage curve. Owning to the large modulation depth, the measured flux noise is as low as 0.34 μΦ 0 /Hz 1/2 . The working field range of the SQUID is greater than 0.5 T parallel to the SQUID plane. We believe that 3-D Nb nano-SQUIDs provide a promising step toward effective single-spin inductive detection.

arXiv:1612.08149•Nano Letters•Nov 7, 2016•34 citations

Design and Magnetic Field Noise of Magnetometer Using Digital SQUID With Subflux Quantum Feedback

Hiroaki Myoren, Kouhei Takatoku, Masato Naruse +1 more

Digital superconducting quantum interference devices (SQUIDs) based on single-flux quantum (SFQ) logic have attractive characteristics such as wide dynamic ranges and high slew rates. However, the resolution of a typical digital SQUID is limited by SFQ feedback. To realize lower magnetic field noise by magnetometers using digital SQUIDs, we have adopted two feedback combinations: one, utilizing the SFQ input/output for a main loop and the other, using a mutually coupled loop. The main loop receives direct Φ0feedback and subflux quantum feedback Φ0/n, where n is an integer from the mutually coupled loop. The flux resolution for the digital SQUID shows improvement with increasing n and reaches below 40 mΦ0at n = 210; however, the slew rate decreases with increasing n and reaches 1.22 × 106Φ0/s at fc= 1.25 GHz and n = 210. For a magnetometer using a digital SQUID with a pickup loop, we confirmed a magnetic field noise of less than 100 fT/√Hz with a signal bandwidth of 1 MHz for operation frequency fcof 20 GHz.

IEEE Transactions on Applied Superconductivity•May 20, 2016•7 citations

Noise properties of SQUIDs made from nanobridges

S. K. H. Lam

For the fabrication of nanoscale SQUIDs, for example having loop diameters of order 1 µm or smaller, the conventional trilayer window-type Josephson junctions are too large. Instead, we consider the use of nanobridge junctions with dimensions of order 100 nm. The problem of hysteresis in the junctions' current–voltage characteristic (IVC) is avoided by depositing a gold overlayer, which serves as both a thermal and electrical shunt. Noise measurement of dc SQUIDs which incorporate such Nb nanobridges as the Josephson junctions are reported. Devices having different IVCs were fabricated and characterized. The best device has a flux noise of 5 × 10 −6 Φ 0 Hz −1/2 at 4.2 K, and there is no significant increase in the noise level in a static magnetic field up to 2 mT. Techniques for increasing the voltage modulation depth, and hence improving the flux noise performance, are discussed.

Superconductor Science and Technology•Aug 7, 2006•30 citations
We characterize the flux sensitivity of a dispersive 3D aluminum nanobridge superconducting quantum interference device (SQUID) magnetometer as a function of applied in-plane magnetic field. In zero field, we observe an effective flux noise of 17 nΦ0/Hz1/2 with 25 MHz of bandwidth at 150 mK. Flux noise increased by less than a factor of three with parallel magnetic fields up to 61 mT. Operation in higher fields may be possible by decreasing the dimensions of the shunt capacitor in the magnetometer circuit. These devices are thus well suited for observing high-speed dynamics in nanoscale magnets, even in the presence of moderate bias magnetic fields.
Author(s): Antler, Natania | Advisor(s): Siddiqi, Irfan | Abstract: As the cutting edge of science and technology pushes towards smaller length scales, sensing technologies with nanoscale precision become increasingly important. In this thesis I will discuss the optimization and application of a 3D nanobridge SQUID magnetometer for studying solid state spin systems, in particular for sensing impurity spins in diamond. Solid state spins have proposed applications in memory and computation for both classical and quantum computing. Isolated spins typically have longer coherence times, making them attractive qubit candidates, but necessitating the development of very sensitive detectors for readout. This 3D nanobridge SQUID combines the exquisite spatial sensitivity of a traditional nanoSQUID with a large non-linearity on par with a tunnel junction SQUID. This allows us to build a highly sensitive magnetometer which can act as both an efficient flux transducer as well as a nearly quantum limited lumped Josephson Parametric Amplifier. We show that the device has a minimum flux noise of 17 ± 0.9 nΦ0/Hz1/2 with only a factor of ∼2.5 increase in flux noise up to 61 mT. A second generation device with a smaller capacitor achieves field tolerance up to 75 mT. The maximal bandwidth values range from 25-40 MHz in the parametric amplification regime to 70 MHz in the linear regime. This combination of large bandwidth, low flux noise, large flux coupling and field tolerance make this sensor a promising candidate for near-single-spin dynamics measurements.In the last part of this thesis we begin to demonstrate the utility of a nanobridge SQUID magnetometer for characterizing spin systems in the solid state. We use the magnetometer to measure the decay characteristics of P1 centers in diamond. We find that the spin-lattice relaxation time varies with temperature, with an order of magnitude decrease in the decay time between 25 mK and 370 mK.
We describe a dispersive nanoSQUID (nanoscale superconducting quantum interference device) magnetometer comprised of two variable thickness aluminum weak-link Josephson junctions shunted in parallel with an on-chip capacitor. This arrangement forms a nonlinear oscillator with a tunable 4–8 GHz resonant frequency with a quality factor Q = 30 when coupled directly to a 50 Ω transmission line. In the presence of a near-resonant microwave carrier signal, a low frequency flux input generates sidebands that are readily detected using microwave reflectometry. If the carrier excitation is sufficiently strong, then the magnetometer also exhibits parametric gain, resulting in a minimum effective flux noise of 30 n Φ 0 Hz −1/2 with 20 MHz of instantaneous bandwidth. If the magnetometer is followed with a near-quantum-noise-limited Josephson parametric amplifier, we can increase the bandwidth to 60 MHz without compromising sensitivity. This combination of high sensitivity and wide bandwidth with no on-chip dissipation makes this device ideal for local sensing of spin dynamics, both classical and quantum.
There is currently fundamental and technological interest in measuring and manipulating nanoscale magnets, particularly in the quantum coherent regime. To observe the dynamics of such systems one requires a magnetometer with not only exceptional sensitivity but also high gain, wide bandwidth, and low backaction. We demonstrate a dispersive magnetometer consisting of a two-junction superconducting quantum interference device (SQUID) in parallel with an integrated, lumped-element capacitor. Input flux signals are encoded as a phase modulation of the microwave drive tone applied to the magnetometer, resulting in a single quadrature voltage signal. For strong drive power, the nonlinearity of the resonator results in quantum limited, phase sensitive parametric amplification of this signal, which improves flux sensitivity at the expense of bandwidth. Depending on the drive parameters, the device performance ranges from an effective flux noise of 0.29 $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}$Hz${}^{\ensuremath{-}1/2}$ and 20 MHz of signal bandwidth to a noise of 0.14 $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}$Hz${}^{\ensuremath{-}1/2}$ and a bandwidth of 0.6 MHz. These results are in excellent agreement with our theoretical model.
A superconducting quantum interference device (SQUID) miniaturized into the nanoscale is promising in the inductive detection of a single electron spin. A nano-SQUID with a strong spin coupling coefficient, a low flux noise, and a wide working magnetic field range is highly desired in a single spin resonance measurement. Nano-SQUIDs with Dayem bridge junctions excel in a high working field range and in the direct coupling from spins to the bridge. However, the common planar structure of nano-SQUIDs is known for problems such as a shallow flux modulation depth and a troublesome hysteresis in current–voltage curves. Here, we developed a fabrication process for creating three-dimensional (3-D) niobium (Nb) nano-SQUIDs with nanobridge junctions that can be tuned independently. Characterization of the device shows up to 45.9% modulation depth with a reversible current–voltage curve. Owning to the large modulation depth, the measured flux noise is as low as 0.34 μΦ 0 /Hz 1/2 . The working field range of the SQUID is greater than 0.5 T parallel to the SQUID plane. We believe that 3-D Nb nano-SQUIDs provide a promising step toward effective single-spin inductive detection.
Digital superconducting quantum interference devices (SQUIDs) based on single-flux quantum (SFQ) logic have attractive characteristics such as wide dynamic ranges and high slew rates. However, the resolution of a typical digital SQUID is limited by SFQ feedback. To realize lower magnetic field noise by magnetometers using digital SQUIDs, we have adopted two feedback combinations: one, utilizing the SFQ input/output for a main loop and the other, using a mutually coupled loop. The main loop receives direct Φ0feedback and subflux quantum feedback Φ0/n, where n is an integer from the mutually coupled loop. The flux resolution for the digital SQUID shows improvement with increasing n and reaches below 40 mΦ0at n = 210; however, the slew rate decreases with increasing n and reaches 1.22 × 106Φ0/s at fc= 1.25 GHz and n = 210. For a magnetometer using a digital SQUID with a pickup loop, we confirmed a magnetic field noise of less than 100 fT/√Hz with a signal bandwidth of 1 MHz for operation frequency fcof 20 GHz.
For the fabrication of nanoscale SQUIDs, for example having loop diameters of order 1 µm or smaller, the conventional trilayer window-type Josephson junctions are too large. Instead, we consider the use of nanobridge junctions with dimensions of order 100 nm. The problem of hysteresis in the junctions' current–voltage characteristic (IVC) is avoided by depositing a gold overlayer, which serves as both a thermal and electrical shunt. Noise measurement of dc SQUIDs which incorporate such Nb nanobridges as the Josephson junctions are reported. Devices having different IVCs were fabricated and characterized. The best device has a flux noise of 5 × 10 −6 Φ 0 Hz −1/2 at 4.2 K, and there is no significant increase in the noise level in a static magnetic field up to 2 mT. Techniques for increasing the voltage modulation depth, and hence improving the flux noise performance, are discussed.