Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

PREPARING A VACUUM CHAMBER TO TRAP ATOMS, AND THE PRINCIPLES OF A MAGNETO-OPTICAL TRAP

G H Rayner

Published Jan 1, 2010• 1 citation
OpenAlex

Related papers

A PORTABLE MAGNETO-OPTICAL TRAP

Raymond Newell

•Jan 1, 1998•0 citations

A method for loading magneto-optical trap in an ultrahigh vacuum environment

Kavish Bhardwaj, Sourabh Sarkar, Surjya Prakash Ram +2 more

We have developed a method that enables loading a magneto-optical trap (MOT) in an ultrahigh vacuum environment. Nearly 1.0 × 108 atoms of 87Rb are trapped in the MOT at ∼2.0×10−10 Torr base pressure in the chamber. After the MOT loading, we have successfully demonstrated the working of a quadrupole magnetic trap in this chamber with a lifetime of ∼15 s.

arXiv:2206.13271•AIP Advances•Jan 1, 2023•7 citations

Investigations on Individual Atoms in Magneto-Optical and Magnetic Traps

S. aus-der-Wiesche, B. Ueberholz, Frank Strauch +2 more

European Quantum Electronics Conference (EQEC)•Jan 1, 1996•0 citations

Compact magneto-optical trap with a quartz vacuum chamber for miniature gravimeters

Kanxing Weng, Bin Wu, Jiahong Lin +3 more

The realization of a compact magneto-optical trap (MOT) with a quartz vacuum chamber via ultra-low power of a cooling laser is reported. The dependence of the properties of the MOT on key experimental parameters is investigated. The efficiency of capturing atoms of the novel MOT is compared with that of the metal vacuum chamber. The compact quartz vacuum chamber can achieve a maximum rubidium ( 87 R b ) atomic loading rate of about 8 × 10 9 / s with less than 60 mW of the total power of cooling lasers, while the metal chamber obtains the maximum atomic loading rate of about 3 × 10 9 / s with more than 240 mW of the total power of cooling lasers. The compact apparatus avoids undesired effects found in a metal chamber, such as high power consumption and the magnetic-field eddy current effect. This compact MOT is helpful in the design of miniature atomic gravimeters.

Journal of the Optical Society of America B•Apr 8, 2020•10 citations

A Review of Optical Cavities in a Magneto-Optical Trap

Jangra, Jagdish

•Jan 1, 2025•0 citations

Pulsed loading of a magneto-optical trap on an atom chip with fast recovery of ultrahigh vacuum

Vivek Singh, Vibhuti Bhushan Tiwari, A Chaudhary +2 more

Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.

arXiv:2403.11458•Laser Physics Letters•Dec 19, 2024•1 citation
The realization of a compact magneto-optical trap (MOT) with a quartz vacuum chamber via ultra-low power of a cooling laser is reported. The dependence of the properties of the MOT on key experimental parameters is investigated. The efficiency of capturing atoms of the novel MOT is compared with that of the metal vacuum chamber. The compact quartz vacuum chamber can achieve a maximum rubidium ( 87 R b ) atomic loading rate of about 8 × 10 9 / s with less than 60 mW of the total power of cooling lasers, while the metal chamber obtains the maximum atomic loading rate of about 3 × 10 9 / s with more than 240 mW of the total power of cooling lasers. The compact apparatus avoids undesired effects found in a metal chamber, such as high power consumption and the magnetic-field eddy current effect. This compact MOT is helpful in the design of miniature atomic gravimeters.
Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.