Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2403.11458 · Laser Physics Letters

Pulsed loading of a magneto-optical trap on an atom chip with fast recovery of ultrahigh vacuum

Vivek Singh, Vibhuti Bhushan Tiwari, A Chaudhary, S Sarkar, Satya Ram Mishra

Published Dec 19, 2024• 1 citation
arXivHTMLPDF

Abstract

Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.

DOI
10.1088/1612-202x/ad9d1f

Related papers

On the continuous loading of a U-magneto-optical trap on an atom-chip in an ultra high vacuum

Vivek Singh, Vibhuti Bhushan Tiwari, Satya Ram Mishra

Abstract Here, we report our studies on the continuous loading of a U-magneto-optical trap (U-MOT) on an atom-chip with a rubidium-(Rb)-vapor-generated background using a dispenser source in an ultra high vacuum environment. Using the U-MOT loading curves, the partial pressure due to the Rb vapor and the pressure due to the background gas have been estimated near the MOT cloud position. The estimated pressure due to the Rb vapor increased from ∼ Torr to Torr as the Rb-dispenser current was increased from 2.8 to 3.4 A. The increase in dispenser current also resulted in a decrease in loading time as well as the lifetime of the MOT cloud. This study will be useful for magnetic trapping experiments where accurate information of the pressure in a chamber is important for the lifetime of the magnetic trap.

arXiv:1912.07934•Laser Physics Letters•Jan 28, 2020•10 citations

Ultrahigh vacuum pressure measurement using magneto-optical trap on atom chip

S. Supakar, Vivek Singh, Vibhuti Bhushan Tiwari +1 more

In this work, the UHV background pressure as low as 1.1×10−10 Torr has been measured using the loss rate characteristics of a vapor-loaded magneto-optical trap (MOT) formed on an atom chip in a UHV chamber. The loss rate due to non-rubidium (Rb) gases in the background in the chamber has been estimated by operating the MOT in low cooling beam intensities and low Rb pressure regimes simultaneously. Using this approach, we minimized the contributions of the intra-trap collisions as well as background MOT species collisions to the measured trap loss rate in our setup. These results can be useful for development of cold-atom based UHV pressure standards.

arXiv:2302.14305•Journal of Applied Physics•Jul 10, 2023•6 citations

Improved transfer efficiency with pulsed atom transfer between two magneto-optical traps

Surjya Prakash Ram, Tiwari, S K, Satya Ram Mishra

In our double magneto-optical trap (MOT) setup containing a vapor chamber MOT (VC-MOT) and an ultra high vacuum MOT (UHV-MOT) for $^{87}$Rb atoms, we find that transfer of atoms from VC-MOT to UHV-MOT can be enhanced by employing a pulsed VC-MOT loading followed by a pulsed push beam, as compared to that obtained by focusing a continuous wave (CW) push beam on a continuously loaded VC-MOT. By choosing appropriately the VC-MOT duration and push beam duration, the number of atoms in UHV-MOT was $\sim$3-times the number obtained with a continuous VC-MOT and a CW push beam of optimized power. The processes affecting the pulsed transfer have been studied.

arXiv:1003.5519•Mar 29, 2010•1 citation

Collimated, single-pass atom source from a pulsed alkali metal dispenser for laser-cooling experiments

Kevin L. Moore, Thomas Purdy, Kater W. Murch +3 more

We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.

arXiv:physics/0409011•Review of Scientific Instruments•Jan 7, 2005•23 citations

Magnetic transport of trapped cold atoms over a large distance

Markus Greiner, Immanuel Bloch, Theodor W. Hänsch +1 more

We report the transport of magnetically trapped cold atoms over a large distance. Atoms are captured in a magneto-optical trap (MOT) and loaded into a magnetic quadrupole trap. The quadrupole potential is then moved over a distance of 33 cm into an ultra-high-vacuum (UHV) chamber using a chain of quadrupole coils. By running suitable currents through the quadrupole coil pairs the trapping geometry of the potential is maintained during the transport process, thus minimizing heating of the trapped atom cloud. Magnetically trapped ${}^{87}\mathrm{Rb}$ atoms at an initial temperature of $T=125 \ensuremath{\mu}\mathrm{K}$ were heated by less than $20 \ensuremath{\mu}\mathrm{K}$ during the transport process, and up to ${10}^{9}$ atoms were transferred into the UHV chamber. Due to the spatial separation of the final magnetic trap and the MOT we have been able to capture atoms in the MOT, while storing magnetically trapped atoms in the UHV chamber.

Physical Review A•Feb 9, 2001•180 citations

An atomic beam source for fast loading of a magneto-optical trap under high vacuum

Peter D. McDowall, Tzahi Grünzweig, Andrew J. Hilliard +1 more

We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.

Review of Scientific Instruments•May 1, 2012•10 citations
Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.
Abstract Here, we report our studies on the continuous loading of a U-magneto-optical trap (U-MOT) on an atom-chip with a rubidium-(Rb)-vapor-generated background using a dispenser source in an ultra high vacuum environment. Using the U-MOT loading curves, the partial pressure due to the Rb vapor and the pressure due to the background gas have been estimated near the MOT cloud position. The estimated pressure due to the Rb vapor increased from ∼ Torr to Torr as the Rb-dispenser current was increased from 2.8 to 3.4 A. The increase in dispenser current also resulted in a decrease in loading time as well as the lifetime of the MOT cloud. This study will be useful for magnetic trapping experiments where accurate information of the pressure in a chamber is important for the lifetime of the magnetic trap.
In this work, the UHV background pressure as low as 1.1×10−10 Torr has been measured using the loss rate characteristics of a vapor-loaded magneto-optical trap (MOT) formed on an atom chip in a UHV chamber. The loss rate due to non-rubidium (Rb) gases in the background in the chamber has been estimated by operating the MOT in low cooling beam intensities and low Rb pressure regimes simultaneously. Using this approach, we minimized the contributions of the intra-trap collisions as well as background MOT species collisions to the measured trap loss rate in our setup. These results can be useful for development of cold-atom based UHV pressure standards.
In our double magneto-optical trap (MOT) setup containing a vapor chamber MOT (VC-MOT) and an ultra high vacuum MOT (UHV-MOT) for 87^{87}87Rb atoms, we find that transfer of atoms from VC-MOT to UHV-MOT can be enhanced by employing a pulsed VC-MOT loading followed by a pulsed push beam, as compared to that obtained by focusing a continuous wave (CW) push beam on a continuously loaded VC-MOT. By choosing appropriately the VC-MOT duration and push beam duration, the number of atoms in UHV-MOT was $\sim$3-times the number obtained with a continuous VC-MOT and a CW push beam of optimized power. The processes affecting the pulsed transfer have been studied.
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.
We report the transport of magnetically trapped cold atoms over a large distance. Atoms are captured in a magneto-optical trap (MOT) and loaded into a magnetic quadrupole trap. The quadrupole potential is then moved over a distance of 33 cm into an ultra-high-vacuum (UHV) chamber using a chain of quadrupole coils. By running suitable currents through the quadrupole coil pairs the trapping geometry of the potential is maintained during the transport process, thus minimizing heating of the trapped atom cloud. Magnetically trapped 87Rb{}^{87}\mathrm{Rb}87Rb atoms at an initial temperature of $T=125 \ensuremath{\mu}\mathrm{K}$ were heated by less than $20 \ensuremath{\mu}\mathrm{K}$ during the transport process, and up to 109{10}^{9}109 atoms were transferred into the UHV chamber. Due to the spatial separation of the final magnetic trap and the MOT we have been able to capture atoms in the MOT, while storing magnetically trapped atoms in the UHV chamber.
We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.