Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Compact magneto-optical trap with a quartz vacuum chamber for miniature gravimeters

Kanxing Weng, Bin Wu, Jiahong Lin, Yin Zhou, Bing Cheng, Qiang Lin

Published Apr 8, 2020• 10 citations
Publisher

Abstract

The realization of a compact magneto-optical trap (MOT) with a quartz vacuum chamber via ultra-low power of a cooling laser is reported. The dependence of the properties of the MOT on key experimental parameters is investigated. The efficiency of capturing atoms of the novel MOT is compared with that of the metal vacuum chamber. The compact quartz vacuum chamber can achieve a maximum rubidium ( 87 R b ) atomic loading rate of about 8 × 10 9 / s with less than 60 mW of the total power of cooling lasers, while the metal chamber obtains the maximum atomic loading rate of about 3 × 10 9 / s with more than 240 mW of the total power of cooling lasers. The compact apparatus avoids undesired effects found in a metal chamber, such as high power consumption and the magnetic-field eddy current effect. This compact MOT is helpful in the design of miniature atomic gravimeters.

DOI
10.1364/josab.390512

Related papers

Realization of the Compact Magneto-Optical Trap Based on Single Laser with Frequency Modulation

Shuning Bao, Bin Wu, Pengfei Cao +9 more

In cold atom physics, the complexity of traditional magneto-optical trap system limits the use of their associated instruments for field applications in atomic physics, such as gravity mapping, space navigation and deep space exploration. This study introduces a novel compact MOT design that addresses these issues by simplifying the structure and reducing the size. The height of the unit is 0.7 m, the volume is 6.3×10−2m3 and the mass is 11.32 kg. The new design utilizes a single laser to generate the two different frequencies needed for laser cooling by internally splitting the beam, shifting the frequency and then combining them, effectively controlling both the cooling and repumping beams. The compact vacuum chamber optical path, in conjunction with the magnetic field, facilitates the capture of 87Rb atoms in an ultra-high vacuum environment. Experimental results demonstrate an atom loading rate of up to 1.79×10787Rb atoms per second, confirming the system’s effectiveness in capturing and cooling 87Rb atoms. This design provides a flexible and portable solution, offering valuable insights for the advancement of compact MOT and its applications in cold atom physics.

Photonics•Jan 23, 2025•0 citations

Miniaturization of physics system in Sr optical clock

Zhao Fang-Jing, Gao Feng, 韩建新 HAN Jian-xin +6 more

The compactness and robustness of the vacuum setup are the major limitations to develop transportable and space-borne optical clocks. The first step in the engineering challenge is to reduce volume and weight with respect to a stationary system. In this paper, we present the realization of a miniaturized vacuum system by building two anti-Helmholtz coils inside the vacuum magneto-optical-trap (MOT) chamber. The built-in coils are specially designed to minimize the distance between the coils, and in this way it is possible to reduce the current needed to realize a typical magnetic gradient of 40 Gs/cm required for blue MOT. When the MOT coil current is 2 A, an axial magnetic field gradient of 43 Gs/cm is obtained in the center of the MOT, which is enough for the first stage Doppler cooling. This novel design allows us to reduce size, weight and power consumption with respect to a traditional laser cooling apparatus, and simultaneously avoid complicating the water cooling equipment. Our vacuum system has a size of 60 cm×20 cm×15 cm, about 1/10 of the original system in the laboratory. In addition, the circularly polarized Zeeman slowing laser is sent to counter propagating atomic beam, and atoms at a few hundred meters per second are now routinely slowed down to velocities of tens of meters per second. As a result, about 16.4% of the atoms are actually trapped into the blue MOT. The final temperature of the blue MOT is approximately 10.6 mK, and the internal diameter is 1.5 mm by observing the expansion of the atoms from the MOT. The populations of cold atoms finally trapped in the MOT are 1.6×106 of 88Sr and 1.5×105 of 87Sr. The 1S0 → 1P1 transition used for the blue MOT is not perfectly closed due to the decay channel of the 5p1P1 → 4d1D2, and a part of atoms are stored in the 3P2 and 3P0 states. To prevent the atoms from losing, 707 and 679 nm repumping lasers are employed to recycle these atoms in the 3P1 state, and then the atoms decay to the ground state 1S0. Now the typical number of loaded atoms dramatically increases by 5 times compared with before. The slowing efficiency of Zeeman slower is also optimized for the operation with deceleration related to the parameter of magnet length, which uses more effectively available magnetic field distribution, in contrast to the usual constant deceleration mode. Our future work will focus on constructing a Zeeman slower combined with permanent magnets or an electric magnet for better tuning of the magnetic field.

Acta Physica Sinica•Jan 1, 2018•4 citations

Multistage two-dimensional magneto-optical trap as a compact cold atom beam source

Jaime Ramirez-Serrano, Nan Yu, James M. Kohel +2 more

A compact cold atom beam source based on a multistage two-dimensional magneto-optical trap (MOT) has been demonstrated and characterized. The multiple-stage design greatly reduces the overall size of the source apparatus while providing a high flux of atoms. The cold atom beam was used to load a separate MOT in ultrahigh vacuum, and we obtained an actual trap loading rate of 1.5 x 109 atoms/s while using only 20 mW of total laser power for the source. The entire source apparatus, including optics, can fit into a 4 cm x 4 cm x 13 cm volume.

Optics Letters•Mar 15, 2006•21 citations

Miniaturized vacuum package for magneto-optical trapping of strontium

Julian Pick, Eric Henker, Florian Löwinger +17 more

Quantum sensors, like optical lattice clocks, undergo a continuous development from lab-based towards mobile systems. A key aspect in the miniaturization of the experimental setups is the development of compact atom sources. Conventional atom sources for alkaline-earth-like elements consist of a high-power oven and a six-beam magneto-optical trap (MOT) inside of vacuum chamber with extensive flanges, viewports and electrical feedthroughs. Here we present a highly compact vacuum package utilizing key technologies for future quantum sensor systems: A chip-based low-power atomic oven, a planar grating MOT chip, and a miniaturized vacuum pump all held inside an additively manufactured titanium vacuum chamber, featuring custom-sized vacuum flanges. In this miniaturized setup, spanning a volume of only 750 ml, we trap up to $10^5$ Sr atoms in a MOT, requiring an oven heating power below 1 W.

arXiv:2609.09846•Sep 9, 2026•0 citations

Compact magneto-optical trap of thulium atoms for a transportable optical clock

Artem A. Golovizin, Dmitry O. Tregubov, D. Mishin +2 more

We have developed a compact vacuum system for laser cooling and spectroscopy of neutral thulium atoms. Compactness is achieved by obviating a classical Zeeman slower section and placing an atomic oven close to a magneto-optical trap (MOT), specifically at the distance of 11 cm. In this configuration, we significantly gained in solid angle of an atomic beam, which is affected by MOT laser beams, and reached 1 million atoms loaded directly in the MOT with only 15 mW of MOT cooling beams net power. By exploiting Zeeman-like deceleration of atoms with an additional laser beam and tailoring the MOT magnetic field gradient with a small magnetic coil, we demonstrated trapping of up to 13 million atoms. These results show great perspective of the developed setup for realizing a compact high-performance optical atomic clock based on thulium atoms.

arXiv:2105.02145•Optics Express•Sep 3, 2021•20 citations

Loading and Compression of a Large Number of Rubidium Atoms Using a Semi-Dark Type Magneto-Optical Trap

Lan‐Sheng Yang, Bai-Tzeng Han, De-Sheng Hong +2 more

We have built an apparatus for setting up a double magneto-optical trap (double MOT) which allows more than 10 Rb atoms to be loaded in 15 seconds. This compact system consists mainly of a stainless steel chamber and a homemade glass cell. The two chambers are spatially separated by a small diameter transfer tube for differential pumping. The stainless steel chamber is maintained at a pressure of 10 Torr, enabling fast capturing of background Rb atoms. The optically cooled atomic clouds are pushed by a laser beam towards the glass cell which is in a much higher vacuum. Under this condition, the glass cell provides a rather long life time for holding the atoms. After the atoms are loaded in the temporarily bright MOT, a semi-dark type MOT compression is employed to reach a spatial density of 1×10 atoms/cm. The compressed atom clouds are further cooled by polarization gradient cooling to a temperature of 30 μK. The high phase space density cloud is suitable for experiments related to ultracold atoms.

Chinese Journal of Physics•Dec 1, 2007•3 citations
The realization of a compact magneto-optical trap (MOT) with a quartz vacuum chamber via ultra-low power of a cooling laser is reported. The dependence of the properties of the MOT on key experimental parameters is investigated. The efficiency of capturing atoms of the novel MOT is compared with that of the metal vacuum chamber. The compact quartz vacuum chamber can achieve a maximum rubidium ( 87 R b ) atomic loading rate of about 8 × 10 9 / s with less than 60 mW of the total power of cooling lasers, while the metal chamber obtains the maximum atomic loading rate of about 3 × 10 9 / s with more than 240 mW of the total power of cooling lasers. The compact apparatus avoids undesired effects found in a metal chamber, such as high power consumption and the magnetic-field eddy current effect. This compact MOT is helpful in the design of miniature atomic gravimeters.
In cold atom physics, the complexity of traditional magneto-optical trap system limits the use of their associated instruments for field applications in atomic physics, such as gravity mapping, space navigation and deep space exploration. This study introduces a novel compact MOT design that addresses these issues by simplifying the structure and reducing the size. The height of the unit is 0.7 m, the volume is 6.3×10−2m3 and the mass is 11.32 kg. The new design utilizes a single laser to generate the two different frequencies needed for laser cooling by internally splitting the beam, shifting the frequency and then combining them, effectively controlling both the cooling and repumping beams. The compact vacuum chamber optical path, in conjunction with the magnetic field, facilitates the capture of 87Rb atoms in an ultra-high vacuum environment. Experimental results demonstrate an atom loading rate of up to 1.79×10787Rb atoms per second, confirming the system’s effectiveness in capturing and cooling 87Rb atoms. This design provides a flexible and portable solution, offering valuable insights for the advancement of compact MOT and its applications in cold atom physics.
The compactness and robustness of the vacuum setup are the major limitations to develop transportable and space-borne optical clocks. The first step in the engineering challenge is to reduce volume and weight with respect to a stationary system. In this paper, we present the realization of a miniaturized vacuum system by building two anti-Helmholtz coils inside the vacuum magneto-optical-trap (MOT) chamber. The built-in coils are specially designed to minimize the distance between the coils, and in this way it is possible to reduce the current needed to realize a typical magnetic gradient of 40 Gs/cm required for blue MOT. When the MOT coil current is 2 A, an axial magnetic field gradient of 43 Gs/cm is obtained in the center of the MOT, which is enough for the first stage Doppler cooling. This novel design allows us to reduce size, weight and power consumption with respect to a traditional laser cooling apparatus, and simultaneously avoid complicating the water cooling equipment. Our vacuum system has a size of 60 cm×20 cm×15 cm, about 1/10 of the original system in the laboratory. In addition, the circularly polarized Zeeman slowing laser is sent to counter propagating atomic beam, and atoms at a few hundred meters per second are now routinely slowed down to velocities of tens of meters per second. As a result, about 16.4% of the atoms are actually trapped into the blue MOT. The final temperature of the blue MOT is approximately 10.6 mK, and the internal diameter is 1.5 mm by observing the expansion of the atoms from the MOT. The populations of cold atoms finally trapped in the MOT are 1.6×106 of 88Sr and 1.5×105 of 87Sr. The 1S0 → 1P1 transition used for the blue MOT is not perfectly closed due to the decay channel of the 5p1P1 → 4d1D2, and a part of atoms are stored in the 3P2 and 3P0 states. To prevent the atoms from losing, 707 and 679 nm repumping lasers are employed to recycle these atoms in the 3P1 state, and then the atoms decay to the ground state 1S0. Now the typical number of loaded atoms dramatically increases by 5 times compared with before. The slowing efficiency of Zeeman slower is also optimized for the operation with deceleration related to the parameter of magnet length, which uses more effectively available magnetic field distribution, in contrast to the usual constant deceleration mode. Our future work will focus on constructing a Zeeman slower combined with permanent magnets or an electric magnet for better tuning of the magnetic field.
A compact cold atom beam source based on a multistage two-dimensional magneto-optical trap (MOT) has been demonstrated and characterized. The multiple-stage design greatly reduces the overall size of the source apparatus while providing a high flux of atoms. The cold atom beam was used to load a separate MOT in ultrahigh vacuum, and we obtained an actual trap loading rate of 1.5 x 109 atoms/s while using only 20 mW of total laser power for the source. The entire source apparatus, including optics, can fit into a 4 cm x 4 cm x 13 cm volume.
Quantum sensors, like optical lattice clocks, undergo a continuous development from lab-based towards mobile systems. A key aspect in the miniaturization of the experimental setups is the development of compact atom sources. Conventional atom sources for alkaline-earth-like elements consist of a high-power oven and a six-beam magneto-optical trap (MOT) inside of vacuum chamber with extensive flanges, viewports and electrical feedthroughs. Here we present a highly compact vacuum package utilizing key technologies for future quantum sensor systems: A chip-based low-power atomic oven, a planar grating MOT chip, and a miniaturized vacuum pump all held inside an additively manufactured titanium vacuum chamber, featuring custom-sized vacuum flanges. In this miniaturized setup, spanning a volume of only 750 ml, we trap up to 10510^5105 Sr atoms in a MOT, requiring an oven heating power below 1 W.
We have developed a compact vacuum system for laser cooling and spectroscopy of neutral thulium atoms. Compactness is achieved by obviating a classical Zeeman slower section and placing an atomic oven close to a magneto-optical trap (MOT), specifically at the distance of 11 cm. In this configuration, we significantly gained in solid angle of an atomic beam, which is affected by MOT laser beams, and reached 1 million atoms loaded directly in the MOT with only 15 mW of MOT cooling beams net power. By exploiting Zeeman-like deceleration of atoms with an additional laser beam and tailoring the MOT magnetic field gradient with a small magnetic coil, we demonstrated trapping of up to 13 million atoms. These results show great perspective of the developed setup for realizing a compact high-performance optical atomic clock based on thulium atoms.
We have built an apparatus for setting up a double magneto-optical trap (double MOT) which allows more than 10 Rb atoms to be loaded in 15 seconds. This compact system consists mainly of a stainless steel chamber and a homemade glass cell. The two chambers are spatially separated by a small diameter transfer tube for differential pumping. The stainless steel chamber is maintained at a pressure of 10 Torr, enabling fast capturing of background Rb atoms. The optically cooled atomic clouds are pushed by a laser beam towards the glass cell which is in a much higher vacuum. Under this condition, the glass cell provides a rather long life time for holding the atoms. After the atoms are loaded in the temporarily bright MOT, a semi-dark type MOT compression is employed to reach a spatial density of 1×10 atoms/cm. The compressed atom clouds are further cooled by polarization gradient cooling to a temperature of 30 μK. The high phase space density cloud is suitable for experiments related to ultracold atoms.