Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annales de Physique

Measurement of the refraction index for atom waves

Marion Jacquey, M Büchner, G. Trénec, J. Vigué

Published Jan 1, 2007• 0 citations
Publisher

Abstract

We have developed a Mach-Zehnder atom interferometer which uses elastic diffraction of lithium atom on laser standing waves for the coherent manipulation of the atom wave. The interference signal is of sufficient quality to achieve a phase sensitivity near 10 milliradians/. With this apparatus, we have recently measured the index of refraction of several gases for lithium waves. The interference signals give access to the real and imaginary parts of () and we have tested the linear dependence of these two quantities with gas density. The measured values of () are in good agreement with calculations and they exhibit glory oscillations, as predicted by theory.

DOI
10.1051/anphys:2008038

Related papers

First Measurements of the Index of Refraction of Gases for Lithium Atomic Waves

Marion Jacquey, M Büchner, G. Trénec +1 more

We report the first measurements of the index of refraction of gases for lithium waves. Using an atom interferometer, we have measured the real and imaginary parts of the index of refraction n for argon, krypton, and xenon as a function of the gas density for several velocities of the lithium beam. The linear dependence of (n-1) with the gas density is well verified. The total collision cross section deduced from the imaginary part of (n-1) is in very good agreement with traditional measurements of this quantity. Finally, the real and imaginary parts of (n-1) and their ratio rho exhibit glory oscillations, in good agreement with calculations.

arXiv:quant-ph/0611236•Physical Review Letters•Jun 15, 2007•20 citations

Lithium atom interferometry

Marion Jacquey, Alain Miffre, M Büchner +2 more

Abstract. We have built an atom interferometer of the Mach Zehnder type. The atomic wave (dB = 54 pm) is a supersonic beam of lithium seeded in argon. The realization of mirrors and beams splitters for the atomic wave relies on elastic Bragg diffraction on laser standing waves at = 671 nm. We first present our experimental setup and signals with atomic fringes which exhibit a very high visibility, up to 84.5 ± 1%, and a very large phase sensitivity. This phase sensitivity is then used to perform an absolute measurement of the lithium atom electric polarizability by applying an electric field on only one atomic beam in the interferometer. Our result, = (24.33 ± 0.16) × 10−30 m3, reduces by a factor three the uncertainty of the best previous measurement. 1.

Journal de Physique IV (Proceedings)•Oct 1, 2006•3 citations

Measuring Atomic Properties with an Atom Interferometer

Tony Roberts

Two experiments are presented which measure atomic properties using an atom interferometer. The interferometer splits the sodium de Broglie wave into two paths, one of which travels through an interaction region. The paths are recombined, and the interference pattern exhibits a phase shift depending on the strength of the interaction. In the first experiment, the interaction involves a gas. De Broglie waves traveling through the gas experience a phase shift represented by an index of refraction. By measuring the index of refraction at various wavelengths, the predicted phenomenon of glory oscillations in the phase shift has been observed for the first time. The index of refraction has been measured for sodium atoms in gases of argon, krypton, xenon, and nitrogen over a wide range of wavelength. These measurements offer detailed insight into the interatomic potential between sodium atoms and the gases. Theoretical predictions of the interatomic potentials are challenged by these results, which should encourage a renewed effort to better understand these potentials. The second experiment measures atomic polarizability with an atom interferometer. Here, the interaction is with an electric field; the atom experiences a phase shift proportional to its energy inside the field. Previously, this method was used to perform the most accurate (< 1%) measurement of sodium polarizability. The precision was limited, however, by the spread of velocities in the atomic beam-the phase shift is different depending on velocity, and the -interference pattern is washed out.

•Jan 1, 2002•2 citations

An atom interferometer using thermal lithium atoms

Alain Miffre, Marion Jacquey, R. Delhuille +4 more

Abstract. We have built an atom interferometer of the Mach-Zehnder type, operating with thermal lithium atoms [1]. Its design is largely inspired by previous works done by the groups of D. Pritchard [2], A. Zeilinger [3] and S.A. Lee [4]. In our apparatus, the atomic wave is diffracted in the Bragg regime by three laser sanding waves to achieve a Mach-Zehnder configuration. This paper briefly recalls the diffraction process and shows the experimental results obtained in our group. Our apparatus is able to achieve a high fringe contrast of 74 % with a large mean detected atom flux of 1.5 × 104 s-1. Finally, the paper ends with the measurement of the velocity distribution of our lithium beam using a light induced fluorescence technique. 1. DIFFRACTION OF THE LITHIUM ATOMIC WAVE IN THE BRAGG REGIME Diffraction of an atomic wave by a laser standing wave in the Bragg regime is in complete analogy with diffraction of x-rays by a crystal. The laser standing wave acts as a thick phase grating for the atomic wave with a periodicity of half the laser wavelength λ r. The diffraction process is governed by conservation of momentum and energy. With a thick laser wave, momentum is transferred from the laser to the incident atomic wave only when the Bragg condition λr sin(θB) = pλdB is fulfilled, where θB is the Bragg angle and p is the diffraction order. For lithium, λr = 671 nm, and the first order diffraction angle is θ1 = 2θB = 170 µrad. Diffraction of the lithium atomic wave is seen by tuning the angle i between the mirror and the atomic beam axis as shown in figure 1a. Figure 1b presents the zero-order beam intensity measured with our detector. This signal is symmetrical around the beam axis and the Bragg condition is fulfilled for ±1 diffraction orders. Figure 1a. Experimental set-up for Bragg diffraction. Figure 1b. Zero-order beam intensity as a function of the angle i between the mirror and the beam axis.

Journal de Physique IV (Proceedings)•Nov 1, 2004•0 citations

Refractive Index for Atomic Waves: Theory and Detailed Calculations

C. Champenois, E. Audouard, P. Duplàa +1 more

This paper describes new theoretical results and calculations concerning the recently introduced index of refraction of a gas for atomic waves. More precisely, the motion of the atoms of the gas is taken into account and the equation describing the Doppler and Fizeau effects is introduced. The case where the atoms of the wave and the gas have spin 1/2 is also discussed and the rotatory power and circular dichroism of an optically pumped gas is calculated. Finally, the index of the rare gases for sodium waves is calculated. The results show how important it is to take into account glory scattering and Doppler averaging to make a meaningful comparison with experiments. The index appears to be very sensitive to the precise value of the quantum parameter B = 2μDeσ2 (in atomic unit). Using the available interaction potential curves, we obtained a reasonably good agreement between the measurements and the corresponding calculated values. However, some experimental results appear difficult to explain with the best available interaction potentials.

Journal de Physique II•Apr 1, 1997•16 citations

Measuring decoherence and the matter-wave index of refraction with an improved atom interferometer

David A. Kokorowski

This thesis describes experiments performed using the MIT atom interferometer, which has recently been upgraded to provide increased experimental precision and flexibility. The three-gratings comprising our Mach-Zehnder interferometer have been installed on a vibration isolated platform which has reduced rms motion of the gratings by a factor of two. The arrangement of gratings on the platform can be reconfigured at will, and the entire platform removed from the vacuum chamber for purposes of alignment. We have performed a series of experiments related to decoherence in an atom interferometer. We have explored decoherence due to photon scattering, in particular the transition from single- to multiple-photon decoherence, and have quantitatively verified the decoherence rate constant in the many-photon regime. We have also examined decoherence due to background gas scattering. Finally, we have investigated the distinction between decoherence and classical dephasing by comparing experiments which illustrate each of these phenomena. We have made new measurements of the index of refraction of argon for sodium matter-waves. Our results are twice as precise previous measurements but suffer from significant systematic error. A detailed study of systematics is presented along with concrete proposals for minimizing their effect in future matter-wave index of refraction measurements.

•Jan 1, 2001•2 citations
We have developed a Mach-Zehnder atom interferometer which uses elastic diffraction of lithium atom on laser standing waves for the coherent manipulation of the atom wave. The interference signal is of sufficient quality to achieve a phase sensitivity near 10 milliradians/. With this apparatus, we have recently measured the index of refraction of several gases for lithium waves. The interference signals give access to the real and imaginary parts of () and we have tested the linear dependence of these two quantities with gas density. The measured values of () are in good agreement with calculations and they exhibit glory oscillations, as predicted by theory.
We report the first measurements of the index of refraction of gases for lithium waves. Using an atom interferometer, we have measured the real and imaginary parts of the index of refraction n for argon, krypton, and xenon as a function of the gas density for several velocities of the lithium beam. The linear dependence of (n-1) with the gas density is well verified. The total collision cross section deduced from the imaginary part of (n-1) is in very good agreement with traditional measurements of this quantity. Finally, the real and imaginary parts of (n-1) and their ratio rho exhibit glory oscillations, in good agreement with calculations.
Abstract. We have built an atom interferometer of the Mach Zehnder type. The atomic wave (dB = 54 pm) is a supersonic beam of lithium seeded in argon. The realization of mirrors and beams splitters for the atomic wave relies on elastic Bragg diffraction on laser standing waves at = 671 nm. We first present our experimental setup and signals with atomic fringes which exhibit a very high visibility, up to 84.5 ± 1%, and a very large phase sensitivity. This phase sensitivity is then used to perform an absolute measurement of the lithium atom electric polarizability by applying an electric field on only one atomic beam in the interferometer. Our result, = (24.33 ± 0.16) × 10−30 m3, reduces by a factor three the uncertainty of the best previous measurement. 1.
Two experiments are presented which measure atomic properties using an atom interferometer. The interferometer splits the sodium de Broglie wave into two paths, one of which travels through an interaction region. The paths are recombined, and the interference pattern exhibits a phase shift depending on the strength of the interaction. In the first experiment, the interaction involves a gas. De Broglie waves traveling through the gas experience a phase shift represented by an index of refraction. By measuring the index of refraction at various wavelengths, the predicted phenomenon of glory oscillations in the phase shift has been observed for the first time. The index of refraction has been measured for sodium atoms in gases of argon, krypton, xenon, and nitrogen over a wide range of wavelength. These measurements offer detailed insight into the interatomic potential between sodium atoms and the gases. Theoretical predictions of the interatomic potentials are challenged by these results, which should encourage a renewed effort to better understand these potentials. The second experiment measures atomic polarizability with an atom interferometer. Here, the interaction is with an electric field; the atom experiences a phase shift proportional to its energy inside the field. Previously, this method was used to perform the most accurate (< 1%) measurement of sodium polarizability. The precision was limited, however, by the spread of velocities in the atomic beam-the phase shift is different depending on velocity, and the -interference pattern is washed out.
Abstract. We have built an atom interferometer of the Mach-Zehnder type, operating with thermal lithium atoms [1]. Its design is largely inspired by previous works done by the groups of D. Pritchard [2], A. Zeilinger [3] and S.A. Lee [4]. In our apparatus, the atomic wave is diffracted in the Bragg regime by three laser sanding waves to achieve a Mach-Zehnder configuration. This paper briefly recalls the diffraction process and shows the experimental results obtained in our group. Our apparatus is able to achieve a high fringe contrast of 74 % with a large mean detected atom flux of 1.5 × 104 s-1. Finally, the paper ends with the measurement of the velocity distribution of our lithium beam using a light induced fluorescence technique. 1. DIFFRACTION OF THE LITHIUM ATOMIC WAVE IN THE BRAGG REGIME Diffraction of an atomic wave by a laser standing wave in the Bragg regime is in complete analogy with diffraction of x-rays by a crystal. The laser standing wave acts as a thick phase grating for the atomic wave with a periodicity of half the laser wavelength λ r. The diffraction process is governed by conservation of momentum and energy. With a thick laser wave, momentum is transferred from the laser to the incident atomic wave only when the Bragg condition λr sin(θB) = pλdB is fulfilled, where θB is the Bragg angle and p is the diffraction order. For lithium, λr = 671 nm, and the first order diffraction angle is θ1 = 2θB = 170 µrad. Diffraction of the lithium atomic wave is seen by tuning the angle i between the mirror and the atomic beam axis as shown in figure 1a. Figure 1b presents the zero-order beam intensity measured with our detector. This signal is symmetrical around the beam axis and the Bragg condition is fulfilled for ±1 diffraction orders. Figure 1a. Experimental set-up for Bragg diffraction. Figure 1b. Zero-order beam intensity as a function of the angle i between the mirror and the beam axis.
This paper describes new theoretical results and calculations concerning the recently introduced index of refraction of a gas for atomic waves. More precisely, the motion of the atoms of the gas is taken into account and the equation describing the Doppler and Fizeau effects is introduced. The case where the atoms of the wave and the gas have spin 1/2 is also discussed and the rotatory power and circular dichroism of an optically pumped gas is calculated. Finally, the index of the rare gases for sodium waves is calculated. The results show how important it is to take into account glory scattering and Doppler averaging to make a meaningful comparison with experiments. The index appears to be very sensitive to the precise value of the quantum parameter B = 2μDeσ2 (in atomic unit). Using the available interaction potential curves, we obtained a reasonably good agreement between the measurements and the corresponding calculated values. However, some experimental results appear difficult to explain with the best available interaction potentials.
This thesis describes experiments performed using the MIT atom interferometer, which has recently been upgraded to provide increased experimental precision and flexibility. The three-gratings comprising our Mach-Zehnder interferometer have been installed on a vibration isolated platform which has reduced rms motion of the gratings by a factor of two. The arrangement of gratings on the platform can be reconfigured at will, and the entire platform removed from the vacuum chamber for purposes of alignment. We have performed a series of experiments related to decoherence in an atom interferometer. We have explored decoherence due to photon scattering, in particular the transition from single- to multiple-photon decoherence, and have quantitatively verified the decoherence rate constant in the many-photon regime. We have also examined decoherence due to background gas scattering. Finally, we have investigated the distinction between decoherence and classical dephasing by comparing experiments which illustrate each of these phenomena. We have made new measurements of the index of refraction of argon for sodium matter-waves. Our results are twice as precise previous measurements but suffer from significant systematic error. A detailed study of systematics is presented along with concrete proposals for minimizing their effect in future matter-wave index of refraction measurements.