Measuring decoherence and the matter-wave index of refraction with an improved atom interferometer

David A. Kokorowski

Published Jan 1, 2001• 2 citations
OpenAlex

Abstract

This thesis describes experiments performed using the MIT atom interferometer, which has recently been upgraded to provide increased experimental precision and flexibility. The three-gratings comprising our Mach-Zehnder interferometer have been installed on a vibration isolated platform which has reduced rms motion of the gratings by a factor of two. The arrangement of gratings on the platform can be reconfigured at will, and the entire platform removed from the vacuum chamber for purposes of alignment. We have performed a series of experiments related to decoherence in an atom interferometer. We have explored decoherence due to photon scattering, in particular the transition from single- to multiple-photon decoherence, and have quantitatively verified the decoherence rate constant in the many-photon regime. We have also examined decoherence due to background gas scattering. Finally, we have investigated the distinction between decoherence and classical dephasing by comparing experiments which illustrate each of these phenomena. We have made new measurements of the index of refraction of argon for sodium matter-waves. Our results are twice as precise previous measurements but suffer from significant systematic error. A detailed study of systematics is presented along with concrete proposals for minimizing their effect in future matter-wave index of refraction measurements.

Related papers

Matter-Wave Decoherence due to a Gas Environment in an Atom Interferometer

Hermann Uys, John D. Perreault, Alexander D. Cronin

Decoherence due to scattering from background gas particles is observed for the first time in a Mach-Zehnder atom interferometer, and compared with decoherence due to scattering photons. A single theory is shown to describe decoherence due to scattering either atoms or photons. Predictions from this theory are tested by experiments with different species of background gas, and also by experiments with different collimation restrictions on an atom beam interferometer.

arXiv:physics/0508197•Physical Review Letters•Oct 5, 2005•41 citations

Measuring Atomic Properties with an Atom Interferometer

Tony Roberts

Two experiments are presented which measure atomic properties using an atom interferometer. The interferometer splits the sodium de Broglie wave into two paths, one of which travels through an interaction region. The paths are recombined, and the interference pattern exhibits a phase shift depending on the strength of the interaction. In the first experiment, the interaction involves a gas. De Broglie waves traveling through the gas experience a phase shift represented by an index of refraction. By measuring the index of refraction at various wavelengths, the predicted phenomenon of glory oscillations in the phase shift has been observed for the first time. The index of refraction has been measured for sodium atoms in gases of argon, krypton, xenon, and nitrogen over a wide range of wavelength. These measurements offer detailed insight into the interatomic potential between sodium atoms and the gases. Theoretical predictions of the interatomic potentials are challenged by these results, which should encourage a renewed effort to better understand these potentials. The second experiment measures atomic polarizability with an atom interferometer. Here, the interaction is with an electric field; the atom experiences a phase shift proportional to its energy inside the field. Previously, this method was used to perform the most accurate (< 1%) measurement of sodium polarizability. The precision was limited, however, by the spread of velocities in the atomic beam-the phase shift is different depending on velocity, and the -interference pattern is washed out.

•Jan 1, 2002•2 citations

From Single- to Multiple-Photon Decoherence in an Atom Interferometer

David A. Kokorowski, Alexander D. Cronin, Tony Roberts +1 more

We measure the decoherence of a spatially separated atomic superposition due to spontaneous photon scattering. We observe a qualitative change in decoherence versus separation as the number of scattered photons increases, and verify quantitatively the decoherence rate constant in the many-photon limit. Our results illustrate an evolution of decoherence consistent with general models developed for a broad class of decoherence phenomena.

arXiv:quant-ph/0009044•Physical Review Letters•Mar 12, 2001•101 citations

The three-grating Mach Zehnder optical interferometer: a tutorial approach using particle optics

Alain Miffre, R. Delhuille, B. Viaris de Lesegno +3 more

In this paper, we present a tutorial set-up based on an optical three-grating Mach–Zehnder interferometer. As this apparatus is very similar in its principle to the Mach–Zehnder interferometers used with matter waves (neutrons, atoms and molecules), it can be used to familiarize students with particle optics, and in our explanations, we use the complementary points of view of wave optics and particle optics. Finally, we have used this interferometer to measure the index of refraction of BK 7 glass for red light at 633 nm, with a technique equivalent to the one used to measure the index of refraction of solid matter for thermal neutrons. The dimensions of this interferometer and its cost make it very interesting for laboratory courses and the experiment described here can be reproduced by students.

European Journal of Physics•Oct 15, 2002•10 citations

Measurement of the refraction index for atom waves

Marion Jacquey, M Büchner, G. Trénec +1 more

We have developed a Mach-Zehnder atom interferometer which uses elastic diffraction of lithium atom on laser standing waves for the coherent manipulation of the atom wave. The interference signal is of sufficient quality to achieve a phase sensitivity near 10 milliradians/. With this apparatus, we have recently measured the index of refraction of several gases for lithium waves. The interference signals give access to the real and imaginary parts of () and we have tested the linear dependence of these two quantities with gas density. The measured values of () are in good agreement with calculations and they exhibit glory oscillations, as predicted by theory.

Annales de Physique•Jan 1, 2007•0 citations

Decoherence Induced by Stochastic Noise in Matter-Wave Interferometers for Gravity Experiments

Mengzhi Wu

Matter-wave interferometry is a striking quantum phenomenon that differs fundamentally from classical mechanics. In the quantum regime, matter behaves like a wave and can exist in spatial superpositions, allowing a single quantum object to move along multiple trajectories simultaneously. Similar to optical interferometers, such quantum matter systems act as interferometers themselves, with the differential phase that encodes information about external forces experienced during their evolution. This makes matter-wave interferometry a powerful platform for quantum sensing across various applications: (i) One of the most direct applications is precision measurement. Atomic interferometers can measure local acceleration and have already been implemented in devices such as accelerometers, seismometers, gravimeters, and gradiometers. (ii) Atomic interferometers are proposed as complementary tools for future gravitational-wave observatories, including ongoing projects MIGA, MAGIS-100, AION and ZAIGA. (iii) Matter-wave interferometry also offers a promising platform for probing quantum aspects of gravity. Numerous tabletop proposals aim to test quantum gravity models, investigate collapse mechanisms, study gravity-induced decoherence, and search for gravity-mediated quantum entanglement. The Stern-Gerlach interferometer (SGI) is a type of matter-wave interferometer that manipulates spatial superpositions using magnetic-field gradients. The witness of an SGI can be designed via its spin, enabling more precise measurements of the differential phase. Recent developments in atomic chip technology have enabled the generation of highly controlled magnetic fields on compact platforms, allowing for precise manipulation of spin states and making SGIs experimentally realizable. Robustness is a critical challenge for matter-wave interferometers. In real experiments, various sources of classical noises arise from mechanical vibrations, seismic motions, inertial forces, tidal forces, magnetic field fluctuations and so on. These noises can disturb the spin and spatial degrees of freedom of the test mass, resulting in witness loss of the interferometer. While spin decoherence is relatively well understood and can be formulated by the Bloch-Redfield master equation, the impact on spatial degrees of freedom still requires systematic investigation. This thesis therefore aims to explore witness loss in an SGI induced by stochastic noises acting on spatial degrees of freedom. As investigated by this thesis, the witness gets lost via several mechanisms: (i) Dephasing. The spatial phase is fluctuated by stochastic noise, resulting in a random phase factor eiδϕ, whose ensemble average contributes a decay factor e−Γ to the spin density matrix and leads to a loss of witness. As is demonstrated by the thesis, this decay factor is a linear response to the external noise, with a transfer function as the Fourier transform of the unperturbed classical trajectories. (ii) Humpty-Dumpty problem. The classical trajectories are also disturbed by stochastic noise, resulting in a non-closure problem of the interferometer, known as the Humpty-Dumpty problem. The resulting witness loss is usually characterized by the contrast of the final states ⟨ψ1|ψ2⟩, which equals the phase-space distance |α1 − α2|2 when the test mass is in coherent states. (iii) Position localization decoherence. Due to the randomness of the noise, the spatial wavefunction of the test mass is thus also stochastic, of which the ensemble average experiences decoherence characterized by the power spectrum density of external noise. However, as illustrated by this thesis, this type of decoherence does not affect spin-based witnesses in most practical scenarios. The general theoretical framework is mainly constructed in chapter 3 of this thesis. The subsequent chapters analyze several representative noise sources: (i) Gravitational and electrostatic noise. Molecules in the surrounding gas move randomly due to thermal motion, generating stochastic gravitational accelerations and electrostatic forces that can be expanded in multipole series. Since the random motion follows Maxwell’s distribution and approximately has a cylindrical symmetry, the resulting noise power spectrum density takes the form of Bessel functions. (ii) Inertial acceleration noise. The mechanical support of the experimental apparatus is always fluctuated by vibrational noise, resulting in random inertial force on the test mass. In practice, dephasing can be mitigated through destructive interference by introducing appropriate coupling between different directional components. (iii) Inertial torsion noise. In suspended experiments, the experimental apparatus is fluctuated by torsional noise, leading to another inertial noise on the test mass. The power spectrum density of the inertial torsion noise is formulated by the selfconvolution of the original noise, resulting in the peak frequencies that are doubled. Taken together, these analyses build a comprehensive picture of how stochastic noise affects the spatial dynamics of an SGI and leads to the loss of spin-based witnesses. Future work may include more realistic noise sources such as magnetic noise and trap-potential noise. These insights will be valuable for future experimental implementations, particularly in precision sensing for quantum gravity, where preserving coherence and maintaining reliable witness signals are essential.

•Apr 8, 2026•0 citations
This thesis describes experiments performed using the MIT atom interferometer, which has recently been upgraded to provide increased experimental precision and flexibility. The three-gratings comprising our Mach-Zehnder interferometer have been installed on a vibration isolated platform which has reduced rms motion of the gratings by a factor of two. The arrangement of gratings on the platform can be reconfigured at will, and the entire platform removed from the vacuum chamber for purposes of alignment. We have performed a series of experiments related to decoherence in an atom interferometer. We have explored decoherence due to photon scattering, in particular the transition from single- to multiple-photon decoherence, and have quantitatively verified the decoherence rate constant in the many-photon regime. We have also examined decoherence due to background gas scattering. Finally, we have investigated the distinction between decoherence and classical dephasing by comparing experiments which illustrate each of these phenomena. We have made new measurements of the index of refraction of argon for sodium matter-waves. Our results are twice as precise previous measurements but suffer from significant systematic error. A detailed study of systematics is presented along with concrete proposals for minimizing their effect in future matter-wave index of refraction measurements.
Two experiments are presented which measure atomic properties using an atom interferometer. The interferometer splits the sodium de Broglie wave into two paths, one of which travels through an interaction region. The paths are recombined, and the interference pattern exhibits a phase shift depending on the strength of the interaction. In the first experiment, the interaction involves a gas. De Broglie waves traveling through the gas experience a phase shift represented by an index of refraction. By measuring the index of refraction at various wavelengths, the predicted phenomenon of glory oscillations in the phase shift has been observed for the first time. The index of refraction has been measured for sodium atoms in gases of argon, krypton, xenon, and nitrogen over a wide range of wavelength. These measurements offer detailed insight into the interatomic potential between sodium atoms and the gases. Theoretical predictions of the interatomic potentials are challenged by these results, which should encourage a renewed effort to better understand these potentials. The second experiment measures atomic polarizability with an atom interferometer. Here, the interaction is with an electric field; the atom experiences a phase shift proportional to its energy inside the field. Previously, this method was used to perform the most accurate (< 1%) measurement of sodium polarizability. The precision was limited, however, by the spread of velocities in the atomic beam-the phase shift is different depending on velocity, and the -interference pattern is washed out.
In this paper, we present a tutorial set-up based on an optical three-grating Mach–Zehnder interferometer. As this apparatus is very similar in its principle to the Mach–Zehnder interferometers used with matter waves (neutrons, atoms and molecules), it can be used to familiarize students with particle optics, and in our explanations, we use the complementary points of view of wave optics and particle optics. Finally, we have used this interferometer to measure the index of refraction of BK 7 glass for red light at 633 nm, with a technique equivalent to the one used to measure the index of refraction of solid matter for thermal neutrons. The dimensions of this interferometer and its cost make it very interesting for laboratory courses and the experiment described here can be reproduced by students.
We have developed a Mach-Zehnder atom interferometer which uses elastic diffraction of lithium atom on laser standing waves for the coherent manipulation of the atom wave. The interference signal is of sufficient quality to achieve a phase sensitivity near 10 milliradians/. With this apparatus, we have recently measured the index of refraction of several gases for lithium waves. The interference signals give access to the real and imaginary parts of () and we have tested the linear dependence of these two quantities with gas density. The measured values of () are in good agreement with calculations and they exhibit glory oscillations, as predicted by theory.
Matter-wave interferometry is a striking quantum phenomenon that differs fundamentally from classical mechanics. In the quantum regime, matter behaves like a wave and can exist in spatial superpositions, allowing a single quantum object to move along multiple trajectories simultaneously. Similar to optical interferometers, such quantum matter systems act as interferometers themselves, with the differential phase that encodes information about external forces experienced during their evolution. This makes matter-wave interferometry a powerful platform for quantum sensing across various applications: (i) One of the most direct applications is precision measurement. Atomic interferometers can measure local acceleration and have already been implemented in devices such as accelerometers, seismometers, gravimeters, and gradiometers. (ii) Atomic interferometers are proposed as complementary tools for future gravitational-wave observatories, including ongoing projects MIGA, MAGIS-100, AION and ZAIGA. (iii) Matter-wave interferometry also offers a promising platform for probing quantum aspects of gravity. Numerous tabletop proposals aim to test quantum gravity models, investigate collapse mechanisms, study gravity-induced decoherence, and search for gravity-mediated quantum entanglement. The Stern-Gerlach interferometer (SGI) is a type of matter-wave interferometer that manipulates spatial superpositions using magnetic-field gradients. The witness of an SGI can be designed via its spin, enabling more precise measurements of the differential phase. Recent developments in atomic chip technology have enabled the generation of highly controlled magnetic fields on compact platforms, allowing for precise manipulation of spin states and making SGIs experimentally realizable. Robustness is a critical challenge for matter-wave interferometers. In real experiments, various sources of classical noises arise from mechanical vibrations, seismic motions, inertial forces, tidal forces, magnetic field fluctuations and so on. These noises can disturb the spin and spatial degrees of freedom of the test mass, resulting in witness loss of the interferometer. While spin decoherence is relatively well understood and can be formulated by the Bloch-Redfield master equation, the impact on spatial degrees of freedom still requires systematic investigation. This thesis therefore aims to explore witness loss in an SGI induced by stochastic noises acting on spatial degrees of freedom. As investigated by this thesis, the witness gets lost via several mechanisms: (i) Dephasing. The spatial phase is fluctuated by stochastic noise, resulting in a random phase factor eiδϕ, whose ensemble average contributes a decay factor e−Γ to the spin density matrix and leads to a loss of witness. As is demonstrated by the thesis, this decay factor is a linear response to the external noise, with a transfer function as the Fourier transform of the unperturbed classical trajectories. (ii) Humpty-Dumpty problem. The classical trajectories are also disturbed by stochastic noise, resulting in a non-closure problem of the interferometer, known as the Humpty-Dumpty problem. The resulting witness loss is usually characterized by the contrast of the final states ⟨ψ1|ψ2⟩, which equals the phase-space distance |α1 − α2|2 when the test mass is in coherent states. (iii) Position localization decoherence. Due to the randomness of the noise, the spatial wavefunction of the test mass is thus also stochastic, of which the ensemble average experiences decoherence characterized by the power spectrum density of external noise. However, as illustrated by this thesis, this type of decoherence does not affect spin-based witnesses in most practical scenarios. The general theoretical framework is mainly constructed in chapter 3 of this thesis. The subsequent chapters analyze several representative noise sources: (i) Gravitational and electrostatic noise. Molecules in the surrounding gas move randomly due to thermal motion, generating stochastic gravitational accelerations and electrostatic forces that can be expanded in multipole series. Since the random motion follows Maxwell’s distribution and approximately has a cylindrical symmetry, the resulting noise power spectrum density takes the form of Bessel functions. (ii) Inertial acceleration noise. The mechanical support of the experimental apparatus is always fluctuated by vibrational noise, resulting in random inertial force on the test mass. In practice, dephasing can be mitigated through destructive interference by introducing appropriate coupling between different directional components. (iii) Inertial torsion noise. In suspended experiments, the experimental apparatus is fluctuated by torsional noise, leading to another inertial noise on the test mass. The power spectrum density of the inertial torsion noise is formulated by the selfconvolution of the original noise, resulting in the peak frequencies that are doubled. Taken together, these analyses build a comprehensive picture of how stochastic noise affects the spatial dynamics of an SGI and leads to the loss of spin-based witnesses. Future work may include more realistic noise sources such as magnetic noise and trap-potential noise. These insights will be valuable for future experimental implementations, particularly in precision sensing for quantum gravity, where preserving coherence and maintaining reliable witness signals are essential.