Physica C Superconductivity

QRNT: a primary thermometer based on an HTS SQUID

John C. Gallop, Ling Hao, Richard Reed

Published Aug 1, 1997• 5 citations
Publisher
DOI
10.1016/s0921-4534(97)01334-8

Related papers

A resistive d.c. SQUID noise thermometer

S. Menkel, D. Drung, C. Aßmann +1 more

Applied Superconductivity•Jul 1, 1998•11 citations

Gigahertz band HTS SQUID amplifier

Michael A. Tarasov, A. Kalabukhov, Z. G. Ivanov +3 more

•Jan 1, 2000•0 citations

Substrate resonator for HTS rf SQUID operation

Y. Zhang, Jürgen Schubert, N. Wolters +3 more

Physica C Superconductivity•Aug 1, 2002•52 citations

The quantum roulette noise thermometer

L. Hao, J.C. Gallop, R.P. Reed +2 more

A novel form of primary thermometer called the quantum roulette noise thermometer (QRNT), based on flux quantisation in a HTS superconducting ring, has been proposed. The basis of the QRNT is that the flux state of a SQUID ring is allowed to evolve freely. The flux state is repeatedly interrogated to establish a probability distribution from which the temperature of the device is derived.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•1 citation

Microwave SQUID for low-temperature detector readout

Fuminori Hirayama

The Japan Society of Applied Physics•Feb 13, 2013•0 citations

HTS SQUID application as a quantum roulette noise thermometer

L. Hao, John C. Gallop, R.P. Reed +2 more

We describe a cryogenic primary thermometer called the Quantum Roulette Noise Thermometer (QRNT), which is based on flux quantisation in a HTS superconducting ring. The basis of the QRNT is that the flux state of a double junction SQUID ring (in thermal contact with a heat bath whose temperature is to be measured) is allowed to evolve freely. The flux state is repeatedly interrogated to establish a probability distribution from which the absolute temperature may be derived. The QRNT is in principle dissipationless and has the potential to provide high accuracy with short measuring time. The QRNT prototype device which employs a YBCO thin film on an MgO bi-crystal substrate has been designed and fabricated. The superconducting ring of overall dimensions 6 mm/spl times/8 mm is broken by two grain boundary Josephson junctions of size 5 /spl mu/m/spl times/3 /spl mu/m. The state of the junctions is switched between superconducting and resistive by means of small currents applied to a superconducting strip line located near the junctions. A dc SQUID, which is used to read out the flux state of the QRNT ring, is operated at 77 K while the QRNT device can be set at any desired temperature above 10 K. Ongoing experimental measurements are described with reference to the expected theoretical predictions.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•3 citations
We describe a cryogenic primary thermometer called the Quantum Roulette Noise Thermometer (QRNT), which is based on flux quantisation in a HTS superconducting ring. The basis of the QRNT is that the flux state of a double junction SQUID ring (in thermal contact with a heat bath whose temperature is to be measured) is allowed to evolve freely. The flux state is repeatedly interrogated to establish a probability distribution from which the absolute temperature may be derived. The QRNT is in principle dissipationless and has the potential to provide high accuracy with short measuring time. The QRNT prototype device which employs a YBCO thin film on an MgO bi-crystal substrate has been designed and fabricated. The superconducting ring of overall dimensions 6 mm/spl times/8 mm is broken by two grain boundary Josephson junctions of size 5 /spl mu/m/spl times/3 /spl mu/m. The state of the junctions is switched between superconducting and resistive by means of small currents applied to a superconducting strip line located near the junctions. A dc SQUID, which is used to read out the flux state of the QRNT ring, is operated at 77 K while the QRNT device can be set at any desired temperature above 10 K. Ongoing experimental measurements are described with reference to the expected theoretical predictions.