Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Japan Society of Applied Physics

Microwave SQUID for low-temperature detector readout

Fuminori Hirayama

Published Feb 13, 2013• 0 citations
OpenAlex

Related papers

Microwave SQUID multiplexer for low-temperature detector readout

Fuminori Hirayama, Satoshi Kohjiro, Daiji Fukuda +5 more

IEICE Technical Report; IEICE Tech. Rep.•Oct 18, 2012•0 citations

Microwave SQUID multiplexers for low-temperature detectors

K. D. Irwin, James A. Beall, William Bertrand Doriese +9 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jan 11, 2006•13 citations

Microwave SQUID Multiplexing of Metallic Magnetic Calorimeters: Status of Multiplexer Performance and Room-Temperature Readout Electronics Development

Mathias Wegner, Nick Karcher, O. Krömer +6 more

Journal of Low Temperature Physics•Feb 26, 2018•28 citations

ADVANCED HYBRID SQUID MULTIPLEXER CONCEPT FOR THE NEXT GENERATION OF ASTRONOMICAL INSTRUMENTS

Inseob Hahn, Peter K. Day, B. Bumble +1 more

The Superconducting Quantum Interference Device (SQUID) has been used and proposed often to read out low-temperature detectors for astronomical instruments. A multiplexed SQUID readout for currently envisioned astronomical detector arrays, which will have tens of thousands of pixels, is still challenging with the present technology. We present a new, advanced multiplexing concept and its prototype development that will allow for the readout of 1,000–10,000 detectors with only three pairs of wires and a single microwave coaxial cable.

WORLD SCIENTIFIC eBooks•May 1, 2009•0 citations

SQUID multiplexers for low-temperature detectors

K. D. Irwin, J. A. Beall, Hsiao-Mei Cho +12 more

Verhandlungen der Deutschen Physikalischen Gesellschaft•Jan 1, 2008•0 citations

The Microwave SQUID Multiplexer

J. A. B. Mates

This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.

•Dec 1, 2011•43 citations
The Superconducting Quantum Interference Device (SQUID) has been used and proposed often to read out low-temperature detectors for astronomical instruments. A multiplexed SQUID readout for currently envisioned astronomical detector arrays, which will have tens of thousands of pixels, is still challenging with the present technology. We present a new, advanced multiplexing concept and its prototype development that will allow for the readout of 1,000–10,000 detectors with only three pairs of wires and a single microwave coaxial cable.
This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.