Ion traps provide an excellent tool for controlling
and observing the state of a single trapped ion. For this reason,
ion traps have been proposed as a possible system for large-scale
quantum computation. However, many obstacles must be overcome
before quantum computing can become a reality. In particular,
perturbations in the electric field due to noise and electrode
charging must be reduced to increase coherence of the motional
quantum state. Gold has been a popular choice in the past due to
its inert properties; however, it is undesirable due its
incompatibility with CMOS technology. This has led to increased
research into alternative CMOS-compatible materials, such as
aluminum and copper. This thesis presents measurements of electric
field noise and light-induced charging in aluminum, copper, and
gold surface electrode traps. In addition, the effect of oxide
growth on field noise and electrode charging is explored by
controlling the thickness of aluminum oxide on several aluminum
traps. The measurements show that electric field noise can be
suppressed in aluminum traps to approximately 10-18 V2 cm-2 Hz-1,
matching the noise exhibited in gold traps, and that copper traps
exhibit noise within an order of magnitude of that in aluminum and
gold. However, the natural oxide of aluminum poses many problems
towards high-performance aluminum ion traps. The electric field
noise is shown to be strongly dependent on the oxide thickness,
increasing the noise by a factor of about 10 until saturation at a
thickness of 13 nm. Charging of surface electrodes is shown to be
highly dependent upon the material, but the model presented does
not match the experimental data and is found to be incomplete.
These results indicate that ion traps made out of CMOS-compatible
materials can perform as well as more traditional traps fabricated
from gold with respect to heating and charging as long as methods
are developed for controlling oxide growth.
An atomic ion is trapped at the tip of a single-mode optical fiber in a cryogenic (8 K) surface-electrode ion trap. The fiber serves as an integrated source of laser light, which drives the quadrupole qubit transition of S88r+. Through in situ translation of the nodal point of the trapping field, the Gaussian beam profile of the fiber output is imaged, and the fiber-ion displacement, in units of the mode waist at the ion, is optimized to within 0.13±0.10 of the mode center despite an initial offset of 3.30±0.10. Fiber-induced charging by 125 μW of 674 nm light is observed to be ∼10 V/m at an ion height of 670 μm, with charging and discharging time constants of 1.6±0.3 s and 4.7±0.6 s, respectively. This work is of importance to large-scale, ion-based quantum information processing, where optics integration in surface-electrode designs may be a crucial enabling technology.
Electric-field noise from ion-trap electrode surfaces can limit the fidelity of multiqubit entangling operations in trapped-ion quantum information processors and can give rise to systematic errors in trapped-ion optical clocks. The underlying mechanism for this noise is unknown, but it has been shown that the noise amplitude can be reduced by energetic ion bombardment, or ``ion milling,'' of the trap electrode surfaces. Using a single trapped
88Sr+ ion as a sensor, we investigate the temperature dependence of this noise both before and after ex situ ion milling of the trap electrodes. Making measurements over a trap electrode temperature range of 4 K to 295 K in both sputtered niobium and electroplated gold traps, we see a marked change in the temperature scaling of the electric-field noise after ion milling: power-law behavior in untreated surfaces is transformed to Arrhenius behavior after treatment. The temperature scaling becomes material-dependent after treatment as well, strongly suggesting that different noise mechanisms are at work before and after ion milling. To constrain potential noise mechanisms, we measure the frequency dependence of the electric-field noise, as well as its dependence on ion-electrode distance, for niobium traps at room temperature both before and after ion milling. These scalings are unchanged by ion milling.