Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Characteristics of electrical field in surface-electrode ion traps

周晓煜, 徐高平

Published Mar 8, 2012• 0 citations
OpenAlex

Related papers

Measurements of electric field noise and light-induced charging in cryogenic surface electrode ion traps

Nathan S. Lachenmyer

•Jan 1, 2010•0 citations

Analytical methods for design of surface-electrode ion traps

Janus H. Wesenberg, Jason Amini, R. B. Blakestad +11 more

Bulletin of the American Physical Society•Jun 7, 2007•1 citation

Distance scaling of electric-field noise in a surface-electrode ion trap

Jonathon A. Sedlacek, Alex Greene, Jules Stuart +4 more

The electric-field noise affecting quantum logic gates in surface-electrode ion traps is studied as a function of trapping frequency, electrode temperature, and distance $d$ between ion and surface. The finding that the noise scales as $1/{d}^{4}$ eliminates various surface-noise models that have been proposed to explain the anomalous ion heating observed in this type of trap.

arXiv:1712.00188•Physical Review A•Feb 15, 2018•50 citations

Evidence for multiple mechanisms underlying surface electric-field noise in ion traps

Jonathon A. Sedlacek, Jules Stuart, D. H. Slichter +4 more

Electric-field noise from ion-trap electrode surfaces can limit the fidelity of multiqubit entangling operations in trapped-ion quantum information processors and can give rise to systematic errors in trapped-ion optical clocks. The underlying mechanism for this noise is unknown, but it has been shown that the noise amplitude can be reduced by energetic ion bombardment, or ``ion milling,'' of the trap electrode surfaces. Using a single trapped $^{88}\mathrm{Sr}^{+}$ ion as a sensor, we investigate the temperature dependence of this noise both before and after ex situ ion milling of the trap electrodes. Making measurements over a trap electrode temperature range of 4 K to 295 K in both sputtered niobium and electroplated gold traps, we see a marked change in the temperature scaling of the electric-field noise after ion milling: power-law behavior in untreated surfaces is transformed to Arrhenius behavior after treatment. The temperature scaling becomes material-dependent after treatment as well, strongly suggesting that different noise mechanisms are at work before and after ion milling. To constrain potential noise mechanisms, we measure the frequency dependence of the electric-field noise, as well as its dependence on ion-electrode distance, for niobium traps at room temperature both before and after ion milling. These scalings are unchanged by ion milling.

arXiv:1809.07761•Physical Review A•Dec 27, 2018•43 citations

Electric field noise in surface ion traps

Crystal Noel, Maya Lewin-Berlin, Clemens Matthiesen +2 more

Bulletin of the American Physical Society•Mar 16, 2017•0 citations

IN SITU PLASMA REMOVAL OF SURFACE CONTAMINANTS FROM ION TRAP ELECTRODES

Raymond A. Haltli

In this thesis, the construction and implementation of an in situ plasma discharge designed to remove surface contaminants from electrodes in an ion trapping experimental system is presented with results. In recent years, many advances have been made in using ion traps for quantum information processing. All of the criteria defined by DiVincenzo for using ion traps for implementing a quantum computer have been individually demonstrated, and in particular surface traps provide a scalable platform for ions. In order to be used for quantum algorithms, trapped ions need to be cooled to their motional (quantum mechanical) ground state. One of the hurdles in integrating surface ion traps for a quantum computer is minimizing electric field noise, which causes the ion to heat out of its motional ground state and which increases with smaller ion-to-electrode distances realized with surface traps. Surface contamination of trap electrodes is speculated to be the primary source of electric field noise. The main goal achieved by this work was to implement an in situ surface cleaning solution for surface electrode ion traps, which would not modify the ion trap electrode surface metal. Care was taken in applying the RF power in order to localize a plasma near the trap electrodes. A method for characterizing the energy of the plasma ions arriving at the ion trap surface is presented and results for plasma ion energies are shown. Finally, a method for quantifying the effectiveness of plasma cleaning of trap electrodes, using the surface analysis technique of X-ray photoelectron spectroscopy for measuring the amount and kind of surface contaminants, is described. A significant advantage of the trap electrode surface cleaning method presented here is the minimal changes necessary for implementation on a working ion trap experimental system.

•Feb 1, 2015•0 citations
The electric-field noise affecting quantum logic gates in surface-electrode ion traps is studied as a function of trapping frequency, electrode temperature, and distance ddd between ion and surface. The finding that the noise scales as 1/d41/{d}^{4}1/d4 eliminates various surface-noise models that have been proposed to explain the anomalous ion heating observed in this type of trap.
Electric-field noise from ion-trap electrode surfaces can limit the fidelity of multiqubit entangling operations in trapped-ion quantum information processors and can give rise to systematic errors in trapped-ion optical clocks. The underlying mechanism for this noise is unknown, but it has been shown that the noise amplitude can be reduced by energetic ion bombardment, or ``ion milling,'' of the trap electrode surfaces. Using a single trapped 88Sr+^{88}\mathrm{Sr}^{+}88Sr+ ion as a sensor, we investigate the temperature dependence of this noise both before and after ex situ ion milling of the trap electrodes. Making measurements over a trap electrode temperature range of 4 K to 295 K in both sputtered niobium and electroplated gold traps, we see a marked change in the temperature scaling of the electric-field noise after ion milling: power-law behavior in untreated surfaces is transformed to Arrhenius behavior after treatment. The temperature scaling becomes material-dependent after treatment as well, strongly suggesting that different noise mechanisms are at work before and after ion milling. To constrain potential noise mechanisms, we measure the frequency dependence of the electric-field noise, as well as its dependence on ion-electrode distance, for niobium traps at room temperature both before and after ion milling. These scalings are unchanged by ion milling.
In this thesis, the construction and implementation of an in situ plasma discharge designed to remove surface contaminants from electrodes in an ion trapping experimental system is presented with results. In recent years, many advances have been made in using ion traps for quantum information processing. All of the criteria defined by DiVincenzo for using ion traps for implementing a quantum computer have been individually demonstrated, and in particular surface traps provide a scalable platform for ions. In order to be used for quantum algorithms, trapped ions need to be cooled to their motional (quantum mechanical) ground state. One of the hurdles in integrating surface ion traps for a quantum computer is minimizing electric field noise, which causes the ion to heat out of its motional ground state and which increases with smaller ion-to-electrode distances realized with surface traps. Surface contamination of trap electrodes is speculated to be the primary source of electric field noise. The main goal achieved by this work was to implement an in situ surface cleaning solution for surface electrode ion traps, which would not modify the ion trap electrode surface metal. Care was taken in applying the RF power in order to localize a plasma near the trap electrodes. A method for characterizing the energy of the plasma ions arriving at the ion trap surface is presented and results for plasma ion energies are shown. Finally, a method for quantifying the effectiveness of plasma cleaning of trap electrodes, using the surface analysis technique of X-ray photoelectron spectroscopy for measuring the amount and kind of surface contaminants, is described. A significant advantage of the trap electrode surface cleaning method presented here is the minimal changes necessary for implementation on a working ion trap experimental system.