A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.
We sympathetically cool highly charged ions (HCI) in Coulomb crystals of Doppler-cooled Be+ ions confined in a cryogenic linear Paul trap that is integrated into a fully enclosing radio-frequency resonator manufactured from superconducting niobium. By preparing a single Be+ cooling ion and a single HCI, quantum logic spectroscopy toward frequency metrology and qubit operations with a great variety of species are enabled. While cooling down the assembly through its transition temperature into the superconducting state, an applied quantization magnetic field becomes persistent, and the trap becomes shielded from subsequent external electromagnetic fluctuations. Using a magnetically sensitive hyperfine transition of Be+ as a qubit, we measure the fractional decay rate of the stored magnetic field to be at the 10-10 s-1 level. Ramsey interferometry and spin-echo measurements yield coherence times of >400 ms, demonstrating excellent passive magnetic shielding at frequencies down to DC.
Recent advancements allow for sympathetic cooling of highly charged ions (HCI) to mK temperatures in a cryogenic linear Paul trap. This makes high precision spectroscopy of HCI possible, paving the way to the search for new physics and novel optical clocks. For this, a highly stable and well-understood Paul trap is required. In particular, excess micromotion needs to be characterized and reduced, since it can limit the lowest achievable ion temperature and therefore spectroscopic precision. Within this thesis, a new cryogenic supply system was partly assembled, which allows for vibrational decoupling of the trap, increasing storage stability. The first cool down test achieved a temperature of 4:23K in the trap environment, which is sufficiently low for superconductive operation of the intended RF-resonator made from niobium. Additionally, a photon-correlation technique was used on the existing cryogenic linear Paul trap using 9Be+ ions for determination of the trap frequency by measuring the phase shift between the driven ions motion and the driving field. From the trap frequency the magnification of the imaging system is deduced. The same photon-correlation technique is used to measure excess micromotion and to demonstrate its reduction by a factor of 100 compared to a previous measurement by using new electronics.
Monolithic three-dimensional (3D) Paul traps combine the high-precision microfabrication of two-dimensional (2D) chip traps with the deep trapping potentials and low heating rates characteristic of macroscopic 3D Paul traps, which are typically machined by traditional means and mechanically assembled. However, achieving low motional heating rates and optical access with a high numerical aperture (NA) while maintaining the high radio-frequency (RF) voltages required for trapping heavy ionic species, such as Yb
+ and Ba
+, remains a significant technical challenge. In this work, we present a fused-silica, monolithic segmented 3D Paul trap with an ion-electrode distance of 250
μm, and stable operation at high RF voltages. We benchmark the performance of the trap using Yb
+ ions, demonstrating axially homogeneous trapping potentials spanning over 200
μm about the axial center of the trap, high multi-directional optical access (up to 0.7 NA), and radial motional heating as low as $\dot{\bar n}=1.1 \pm 0.1 $ quanta/s at radial trap frequencies about 3 MHz near room temperature. Furthermore, we observe a motional Ramsey coherence time,
T2, of about 95 ms for the radial center-of-mass mode. We demonstrate the generation of a two-qubit Bell state with a parity contrast of
99.3−1.5+0.7% with state preparation and measurement correction. These results establish fused-silica monolithic 3D Paul traps as a scalable, modular platform for quantum simulation, computation, metrology, and networking with heavy ionic species.
We demonstrate a linear radio-frequency trap for confining strontium ions that is simply constructed nearly entirely with commercial off-the-shelf components. The electrodes of this trap are spaced to allow tight radial confinement, and segmented to give tight axial confinement with minimal distortion of the radio-frequency field. The resulting secular frequencies of the trap are 1 MHz in the radial direction and 100 kHz in the axial direction, the ions can be imaged with 2–3 μm resolution, and we detect over 20 000 photons per second per ion. This article describes the construction of the vital parts of the trap system, the laser system and optics used to Doppler cool the ions and to observe quantum jumps, and the operation and behavior of the complete system.
We report on the progress on a single-ion optical clock that is being developed at the FEMTO-ST institute. Our objective is to reach a fractional frequency stability of the order of 10-14 at one second for a total volume well below 500 L. The experimental setup is based on a surface electrode single-ion trap. A new trapping chip was designed and produced at the local cleanroom facility, using deep reactive-ion etching (DRIE) on a silicon on insulator- (SOI) wafer. Paul traps require a source of highly-stable and low noise voltage in the radio-frequency (RF) domain. A resonator of our own design has been used to supply high voltage to the trap. We have developed and implemented techniques for 3D micromotion reduction in order to minimize the 2nd order Doppler shift. Indeed, for Yb+ optical spectroscopy, second order Doppler shift and Stark shift due to the ac fields can contribute significantly to the uncertainty budget. We will present the latest results of the trap characterization, which should include lifetime and heating rate measurements of the trap.