arXiv:1901.03082 · Review of Scientific Instruments

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

T. Leopold, S. A. King, P. Micke, A. Bautista-Salvador, J. C. Heip, C. Ospelkaus, J. R. Crespo López-Urrutia, P. O. Schmidt

Published Jul 1, 2019• 55 citations
arXivHTMLPDF

Abstract

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.

DOI
10.1063/1.5100594

Related papers

Sympathetically cooled highly charged ions in a radio-frequency trap with superconducting magnetic shielding

Elwin Dijck, Christian Warnecke, Malte Wehrheim +12 more

We sympathetically cool highly charged ions (HCI) in Coulomb crystals of Doppler-cooled Be+ ions confined in a cryogenic linear Paul trap that is integrated into a fully enclosing radio-frequency resonator manufactured from superconducting niobium. By preparing a single Be+ cooling ion and a single HCI, quantum logic spectroscopy toward frequency metrology and qubit operations with a great variety of species are enabled. While cooling down the assembly through its transition temperature into the superconducting state, an applied quantization magnetic field becomes persistent, and the trap becomes shielded from subsequent external electromagnetic fluctuations. Using a magnetically sensitive hyperfine transition of Be+ as a qubit, we measure the fractional decay rate of the stored magnetic field to be at the 10-10 s-1 level. Ramsey interferometry and spin-echo measurements yield coherence times of >400 ms, demonstrating excellent passive magnetic shielding at frequencies down to DC.

arXiv:2306.01670•Review of Scientific Instruments•Aug 1, 2023•5 citations

An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions

Julian Stark, Christian Warnecke, S. Bogen +17 more

We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of Q ≈ 2.3 × 105 at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts that limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron-beam ion trap, and deceleration beamline supplying highly charged ions (HCIs), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole-mass filter with HCIs and trapping of Doppler-cooled 9Be+ Coulomb crystals.

arXiv:2102.02793•Review of Scientific Instruments•Aug 1, 2021•8 citations

Setup of a vibration-suppressed cryogenic system for a RF ion trap with minimum micromotion

Lukas J. Spieß

Recent advancements allow for sympathetic cooling of highly charged ions (HCI) to mK temperatures in a cryogenic linear Paul trap. This makes high precision spectroscopy of HCI possible, paving the way to the search for new physics and novel optical clocks. For this, a highly stable and well-understood Paul trap is required. In particular, excess micromotion needs to be characterized and reduced, since it can limit the lowest achievable ion temperature and therefore spectroscopic precision. Within this thesis, a new cryogenic supply system was partly assembled, which allows for vibrational decoupling of the trap, increasing storage stability. The first cool down test achieved a temperature of 4:23K in the trap environment, which is sufficiently low for superconductive operation of the intended RF-resonator made from niobium. Additionally, a photon-correlation technique was used on the existing cryogenic linear Paul trap using 9Be+ ions for determination of the trap frequency by measuring the phase shift between the driven ions motion and the driving field. From the trap frequency the magnification of the imaging system is deduced. The same photon-correlation technique is used to measure excess micromotion and to demonstrate its reduction by a factor of 100 compared to a previous measurement by using new electronics.

•Jan 1, 2018•0 citations

Coulomb crystallization of highly charged ions

L. Schmöger, Oscar O. Versolato, M. Schwarz +13 more

Control over the motional degrees of freedom of atoms, ions, and molecules in a field-free environment enables unrivalled measurement accuracies but has yet to be applied to highly charged ions (HCIs), which are of particular interest to future atomic clock designs and searches for physics beyond the Standard Model. Here, we report on the Coulomb crystallization of HCIs (specifically (40)Ar(13+)) produced in an electron beam ion trap and retrapped in a cryogenic linear radiofrequency trap by means of sympathetic motional cooling through Coulomb interaction with a directly laser-cooled ensemble of Be(+) ions. We also demonstrate cooling of a single Ar(13+) ion by a single Be(+) ion-the prerequisite for quantum logic spectroscopy with a potential 10(-19) accuracy level. Achieving a seven-orders-of-magnitude decrease in HCI temperature starting at megakelvin down to the millikelvin range removes the major obstacle for HCI investigation with high-precision laser spectroscopy.

Science•Mar 12, 2015•137 citations

Quantum Logic Spectroscopy of Highly Charged Ions

P. Micke

Fundamental interactions and symmetries define the structure and properties of all matter, in particular of its small and diverse visible constituents—the atoms. The study of their distinctive spectra through precision spectroscopy is therefore a vital tool to advance our understanding of nature. Highly charged ions (HCIs) constitute the largest fraction of all atoms since every atom has as many charge states as electrons it can bind. Although most of the matter on Earth is neutral, HCIs are ubiquitous in the universe and their systematic study is essential not only for atomic physics but eminently for astrophysics, nuclear physics, and fusion research, among others. Recently, HCIs have been identified as ideal candidates for sensitive tests of physics beyond the Standard Model of particle physics and for use in future high-accuracy optical atomic clocks. However, the realization of such proposals has been hindered by the hitherto constrained laboratory control and limited spectroscopic accuracy of about parts-per-million fractional uncertainty levels. This thesis reports the first coherent laser spectroscopy of HCIs, boosting the achievable spectroscopic precision by eight orders of magnitude compared to traditional spectroscopy methods. The 2P1/2–2P3/2 fine-structure ground-state transition in highly charged 40Ar13+ at an optical wavelength of 441 nm was chosen as a proof-of-principle case. A single ion of this species was isolated from a megakelvin-hot plasma cloud and co-trapped together with a laser-cooled singly charged 9Be+ ion in a two-ion crystal, confined in the harmonic potential of a cryogenic linear Paul trap. This coupled quantum-mechanical system was then cooled to its ground state of axial motion, corresponding to the lowest temperature of a HCI ever achieved. The spectroscopy was realized by implementing quantum logic techniques which allow preparation of the quantum state of the HCI and to map its electronic state after spectroscopy onto the 9Be+ logic ion in order to detect it there with high efficiency through electron shelving. In addition to the increase of spectroscopic precision, the excited-state lifetime and g-factor were measured—the latter one to unprecedented accuracy, resolving effects from special relativity, interelectronic interactions, and quantum electrodynamics. Moreover, it settled a discrepancy between theoretical predictions. The demonstrated techniques are not limited to the specific 40Ar13+ species but universally applicable to other HCIs. Thereby, this work unlocks the potential of HCIs for unrivaled tests of fundamental physics, the search for new physics—such as a 5th force, variations of fundamental constants and dark matter candidates—as well as the use of HCIs in novel optical atomic clocks.

•Jan 1, 2020•1 citation

Sideband cooling and coherent dynamics in a microchip multi-segmented ion trap

Stephan A Schulz, Ulrich Poschinger, Frank Ziesel +1 more

Miniaturized ion trap arrays with many trap segments present a promising architecture for scalable quantum information processing. The miniaturization of segmented linear Paul traps allows partitioning the microtrap into different storage and processing zones. The individual position control of many ions—each of them carrying qubit information in its long-lived electronic levels—by the external trap control voltages is important for the implementation of next generation large-scale quantum algorithms. We present a novel scalable microchip multi-segmented ion trap with two different adjacent zones, one for the storage and another dedicated to the processing of quantum information using single ions and linear ion crystals. A pair of radio-frequency-driven electrodes and 62 independently controlled dc electrodes allows shuttling of single ions or linear ion crystals with numerically designed axial potentials at axial and radial trap frequencies of a few megahertz. We characterize and optimize the microtrap using sideband spectroscopy on the narrow S 1/2 ↔D 5/2 qubit transition of the 40 Ca + ion, and demonstrate coherent single-qubit Rabi rotations and optical cooling methods. We determine the heating rate using sideband cooling measurements to the vibrational ground state, which is necessary for subsequent two-qubit quantum logic operations. The applicability for scalable quantum information processing is proved.

arXiv:0712.3249•New Journal of Physics•Apr 30, 2008•95 citations
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.
We sympathetically cool highly charged ions (HCI) in Coulomb crystals of Doppler-cooled Be+ ions confined in a cryogenic linear Paul trap that is integrated into a fully enclosing radio-frequency resonator manufactured from superconducting niobium. By preparing a single Be+ cooling ion and a single HCI, quantum logic spectroscopy toward frequency metrology and qubit operations with a great variety of species are enabled. While cooling down the assembly through its transition temperature into the superconducting state, an applied quantization magnetic field becomes persistent, and the trap becomes shielded from subsequent external electromagnetic fluctuations. Using a magnetically sensitive hyperfine transition of Be+ as a qubit, we measure the fractional decay rate of the stored magnetic field to be at the 10-10 s-1 level. Ramsey interferometry and spin-echo measurements yield coherence times of >400 ms, demonstrating excellent passive magnetic shielding at frequencies down to DC.
We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of Q ≈ 2.3 × 105 at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts that limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron-beam ion trap, and deceleration beamline supplying highly charged ions (HCIs), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole-mass filter with HCIs and trapping of Doppler-cooled 9Be+ Coulomb crystals.
Recent advancements allow for sympathetic cooling of highly charged ions (HCI) to mK temperatures in a cryogenic linear Paul trap. This makes high precision spectroscopy of HCI possible, paving the way to the search for new physics and novel optical clocks. For this, a highly stable and well-understood Paul trap is required. In particular, excess micromotion needs to be characterized and reduced, since it can limit the lowest achievable ion temperature and therefore spectroscopic precision. Within this thesis, a new cryogenic supply system was partly assembled, which allows for vibrational decoupling of the trap, increasing storage stability. The first cool down test achieved a temperature of 4:23K in the trap environment, which is sufficiently low for superconductive operation of the intended RF-resonator made from niobium. Additionally, a photon-correlation technique was used on the existing cryogenic linear Paul trap using 9Be+ ions for determination of the trap frequency by measuring the phase shift between the driven ions motion and the driving field. From the trap frequency the magnification of the imaging system is deduced. The same photon-correlation technique is used to measure excess micromotion and to demonstrate its reduction by a factor of 100 compared to a previous measurement by using new electronics.
Control over the motional degrees of freedom of atoms, ions, and molecules in a field-free environment enables unrivalled measurement accuracies but has yet to be applied to highly charged ions (HCIs), which are of particular interest to future atomic clock designs and searches for physics beyond the Standard Model. Here, we report on the Coulomb crystallization of HCIs (specifically (40)Ar(13+)) produced in an electron beam ion trap and retrapped in a cryogenic linear radiofrequency trap by means of sympathetic motional cooling through Coulomb interaction with a directly laser-cooled ensemble of Be(+) ions. We also demonstrate cooling of a single Ar(13+) ion by a single Be(+) ion-the prerequisite for quantum logic spectroscopy with a potential 10(-19) accuracy level. Achieving a seven-orders-of-magnitude decrease in HCI temperature starting at megakelvin down to the millikelvin range removes the major obstacle for HCI investigation with high-precision laser spectroscopy.
Fundamental interactions and symmetries define the structure and properties of all matter, in particular of its small and diverse visible constituents—the atoms. The study of their distinctive spectra through precision spectroscopy is therefore a vital tool to advance our understanding of nature. Highly charged ions (HCIs) constitute the largest fraction of all atoms since every atom has as many charge states as electrons it can bind. Although most of the matter on Earth is neutral, HCIs are ubiquitous in the universe and their systematic study is essential not only for atomic physics but eminently for astrophysics, nuclear physics, and fusion research, among others. Recently, HCIs have been identified as ideal candidates for sensitive tests of physics beyond the Standard Model of particle physics and for use in future high-accuracy optical atomic clocks. However, the realization of such proposals has been hindered by the hitherto constrained laboratory control and limited spectroscopic accuracy of about parts-per-million fractional uncertainty levels. This thesis reports the first coherent laser spectroscopy of HCIs, boosting the achievable spectroscopic precision by eight orders of magnitude compared to traditional spectroscopy methods. The 2P1/2–2P3/2 fine-structure ground-state transition in highly charged 40Ar13+ at an optical wavelength of 441 nm was chosen as a proof-of-principle case. A single ion of this species was isolated from a megakelvin-hot plasma cloud and co-trapped together with a laser-cooled singly charged 9Be+ ion in a two-ion crystal, confined in the harmonic potential of a cryogenic linear Paul trap. This coupled quantum-mechanical system was then cooled to its ground state of axial motion, corresponding to the lowest temperature of a HCI ever achieved. The spectroscopy was realized by implementing quantum logic techniques which allow preparation of the quantum state of the HCI and to map its electronic state after spectroscopy onto the 9Be+ logic ion in order to detect it there with high efficiency through electron shelving. In addition to the increase of spectroscopic precision, the excited-state lifetime and g-factor were measured—the latter one to unprecedented accuracy, resolving effects from special relativity, interelectronic interactions, and quantum electrodynamics. Moreover, it settled a discrepancy between theoretical predictions. The demonstrated techniques are not limited to the specific 40Ar13+ species but universally applicable to other HCIs. Thereby, this work unlocks the potential of HCIs for unrivaled tests of fundamental physics, the search for new physics—such as a 5th force, variations of fundamental constants and dark matter candidates—as well as the use of HCIs in novel optical atomic clocks.
Miniaturized ion trap arrays with many trap segments present a promising architecture for scalable quantum information processing. The miniaturization of segmented linear Paul traps allows partitioning the microtrap into different storage and processing zones. The individual position control of many ions—each of them carrying qubit information in its long-lived electronic levels—by the external trap control voltages is important for the implementation of next generation large-scale quantum algorithms. We present a novel scalable microchip multi-segmented ion trap with two different adjacent zones, one for the storage and another dedicated to the processing of quantum information using single ions and linear ion crystals. A pair of radio-frequency-driven electrodes and 62 independently controlled dc electrodes allows shuttling of single ions or linear ion crystals with numerically designed axial potentials at axial and radial trap frequencies of a few megahertz. We characterize and optimize the microtrap using sideband spectroscopy on the narrow S 1/2 ↔D 5/2 qubit transition of the 40 Ca + ion, and demonstrate coherent single-qubit Rabi rotations and optical cooling methods. We determine the heating rate using sideband cooling measurements to the vibrational ground state, which is necessary for subsequent two-qubit quantum logic operations. The applicability for scalable quantum information processing is proved.