Characterization of a surface electrode Paul trap for frequency metrology

Josipa Madunic, Moustafa Abdel Hafiz, Y. Kersalé, Clément Lacroûte

Published May 15, 2023• 0 citations
OpenAlex

Abstract

We report on the progress on a single-ion optical clock that is being developed at the FEMTO-ST institute. Our objective is to reach a fractional frequency stability of the order of 10-14 at one second for a total volume well below 500 L. The experimental setup is based on a surface electrode single-ion trap. A new trapping chip was designed and produced at the local cleanroom facility, using deep reactive-ion etching (DRIE) on a silicon on insulator- (SOI) wafer. Paul traps require a source of highly-stable and low noise voltage in the radio-frequency (RF) domain. A resonator of our own design has been used to supply high voltage to the trap. We have developed and implemented techniques for 3D micromotion reduction in order to minimize the 2nd order Doppler shift. Indeed, for Yb+ optical spectroscopy, second order Doppler shift and Stark shift due to the ac fields can contribute significantly to the uncertainty budget. We will present the latest results of the trap characterization, which should include lifetime and heating rate measurements of the trap.

Related papers

Preliminary characterization of a surface electrode Paul trap for frequency metrology

Josipa Madunic, Lucas Groult, Bachir Achi +7 more

Abstract We are developing a single-ion optical clock based on a surface-electrode (SE) trap that we will operate with 171Yb+ ions on the electric quadrupole transition at 435.5 nm. We present heating rate measurements performed with a prototype SE trap. We also introduce a new, micro-fabricated SE trapping chip using silicon on insulator technology. Electric tests were performed under ultra-high vacuum using a testing chip, including breakdown voltages measurements and flashover detection. We present suitable trapping parameters for this chip, as well as a road-map for improving its design.

arXiv:2410.06639•Journal of Physics Conference Series•Nov 1, 2024•0 citations

Development and characterization of a linear ion trap for an improved optical clock performance

T. Burgermeister

Single ion frequency standards have demonstrated in several experiments excellent results and are approaching fractional frequency uncertainties of 10^-18. As dominant contributions to the uncertainty are linked to the ion trap properties a further reduction would be possible by an improved ion trap. Due to the interrogation of a single ion these frequency standards are currently limited by the intrinsically low signal-to-noise ratio and require long averaging times on the order of several days. This limitation is critical for various applications that require a high frequency resolution on short timescales. One possibility to improve the clock stability is to increase the number of clock ions. However, this approach further increases the requirements for the ion trap. Therefore, for the realization of a multi-ion clock that aims at simultaneously reducing the frequency stability and uncertainty the control over the characteristics of the ion trap is crucial. This thesis continues previous work towards the realization of a multi-ion optical clock based on ion Coulomb crystals of 115In+ ions which are sympathetically cooled by 172Yb+ ions. The existing design for a segmented linear ion trap has been refined and a reliable trap manufacturing process for a trap based on gold coated aluminium nitride wafers has been developed. Manufacturing tolerances below 10 μm allowed to reduce the axial micromotion amplitudes substantially. For a region of more than 300 μm the uncertainty contribution of the three-dimensional micromotion amplitude is shown to be below 10^-19. Additionally the radial ion heating rate of the trap has been measured to be 1.1 phonons/s for a trap frequency of 490 kHz. The time dilation shift due to the heating rate on the radial trap axis is found to be (2.1 ± 0.3) x 10^-20 1/s. The trap design has also been optimized for a low trap temperature rise due to the applied rf voltage. Trap temperature measurements with Pt100 sensors installed on the trap showed a maximum temperature increase of 1.21 K at an rf voltage amplitude of 1 kV. By comparing the measurement results to FEM simulations the uncertainty contribution of the trap temperature to the black-body radiation shift has been deduced to be 2.4 x 10^-20. As the ion trap provides a high level of control on Coulomb crystals it also provides an ideal test bed for studying atomic many-body systems. This work presents results of the investigations on topological defects in two-dimensional Coulomb crystals. The emphasis was placed on the effects of mass defects and external electric fields on the stability of the topological defects. It is shown that these effects can be used to manipulate and create topological defects deterministically.

•Jan 1, 2019•3 citations

Evaluation of trap-induced systematic frequency shifts for a multi-ion optical clock at the 10−19level

Jonas Keller, T. Burgermeister, Dimitri Kalincev +2 more

In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .

arXiv:1512.05677•Journal of Physics Conference Series•Jun 1, 2016•29 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations

Spectroscopic characterization of ion motion for an optical clock based on Coulomb crystals

Keller, Jonas

Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.

•Jan 1, 2015•5 citations

Heating rate measurements in a prototype surface-electrode trap for optical frequency metrology

Clément Lacroûte, T. Lauprêtre, Bachir Achi +4 more

In this talk, I will review our recent work on the development of a compact, optical atomic clock based on trapped Yb+ ions. We have developed a simple surface-electrodes microtrap designed towards optical frequency metrology. After reviewing the advantages of microtraps for single-ion optical clocks, I will show our experimental results of heating rate measurements with a simple prototype trap.

•Jun 20, 2022•0 citations
We report on the progress on a single-ion optical clock that is being developed at the FEMTO-ST institute. Our objective is to reach a fractional frequency stability of the order of 10-14 at one second for a total volume well below 500 L. The experimental setup is based on a surface electrode single-ion trap. A new trapping chip was designed and produced at the local cleanroom facility, using deep reactive-ion etching (DRIE) on a silicon on insulator- (SOI) wafer. Paul traps require a source of highly-stable and low noise voltage in the radio-frequency (RF) domain. A resonator of our own design has been used to supply high voltage to the trap. We have developed and implemented techniques for 3D micromotion reduction in order to minimize the 2nd order Doppler shift. Indeed, for Yb+ optical spectroscopy, second order Doppler shift and Stark shift due to the ac fields can contribute significantly to the uncertainty budget. We will present the latest results of the trap characterization, which should include lifetime and heating rate measurements of the trap.
Abstract We are developing a single-ion optical clock based on a surface-electrode (SE) trap that we will operate with 171Yb+ ions on the electric quadrupole transition at 435.5 nm. We present heating rate measurements performed with a prototype SE trap. We also introduce a new, micro-fabricated SE trapping chip using silicon on insulator technology. Electric tests were performed under ultra-high vacuum using a testing chip, including breakdown voltages measurements and flashover detection. We present suitable trapping parameters for this chip, as well as a road-map for improving its design.
Single ion frequency standards have demonstrated in several experiments excellent results and are approaching fractional frequency uncertainties of 10^-18. As dominant contributions to the uncertainty are linked to the ion trap properties a further reduction would be possible by an improved ion trap. Due to the interrogation of a single ion these frequency standards are currently limited by the intrinsically low signal-to-noise ratio and require long averaging times on the order of several days. This limitation is critical for various applications that require a high frequency resolution on short timescales. One possibility to improve the clock stability is to increase the number of clock ions. However, this approach further increases the requirements for the ion trap. Therefore, for the realization of a multi-ion clock that aims at simultaneously reducing the frequency stability and uncertainty the control over the characteristics of the ion trap is crucial. This thesis continues previous work towards the realization of a multi-ion optical clock based on ion Coulomb crystals of 115In+ ions which are sympathetically cooled by 172Yb+ ions. The existing design for a segmented linear ion trap has been refined and a reliable trap manufacturing process for a trap based on gold coated aluminium nitride wafers has been developed. Manufacturing tolerances below 10 μm allowed to reduce the axial micromotion amplitudes substantially. For a region of more than 300 μm the uncertainty contribution of the three-dimensional micromotion amplitude is shown to be below 10^-19. Additionally the radial ion heating rate of the trap has been measured to be 1.1 phonons/s for a trap frequency of 490 kHz. The time dilation shift due to the heating rate on the radial trap axis is found to be (2.1 ± 0.3) x 10^-20 1/s. The trap design has also been optimized for a low trap temperature rise due to the applied rf voltage. Trap temperature measurements with Pt100 sensors installed on the trap showed a maximum temperature increase of 1.21 K at an rf voltage amplitude of 1 kV. By comparing the measurement results to FEM simulations the uncertainty contribution of the trap temperature to the black-body radiation shift has been deduced to be 2.4 x 10^-20. As the ion trap provides a high level of control on Coulomb crystals it also provides an ideal test bed for studying atomic many-body systems. This work presents results of the investigations on topological defects in two-dimensional Coulomb crystals. The emphasis was placed on the effects of mass defects and external electric fields on the stability of the topological defects. It is shown that these effects can be used to manipulate and create topological defects deterministically.
In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.
Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.