Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

Linear Paul trap for strontium ions

Dana J. Berkeland

Published Aug 1, 2002• 51 citations
Publisher

Abstract

We demonstrate a linear radio-frequency trap for confining strontium ions that is simply constructed nearly entirely with commercial off-the-shelf components. The electrodes of this trap are spaced to allow tight radial confinement, and segmented to give tight axial confinement with minimal distortion of the radio-frequency field. The resulting secular frequencies of the trap are 1 MHz in the radial direction and 100 kHz in the axial direction, the ions can be imaged with 2–3 μm resolution, and we detect over 20 000 photons per second per ion. This article describes the construction of the vital parts of the trap system, the laser system and optics used to Doppler cool the ions and to observe quantum jumps, and the operation and behavior of the complete system.

DOI
10.1063/1.1489073

Related papers

An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions

Julian Stark, Christian Warnecke, S. Bogen +17 more

We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of Q ≈ 2.3 × 105 at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts that limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron-beam ion trap, and deceleration beamline supplying highly charged ions (HCIs), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole-mass filter with HCIs and trapping of Doppler-cooled 9Be+ Coulomb crystals.

arXiv:2102.02793•Review of Scientific Instruments•Aug 1, 2021•8 citations

Transport of ions in a segmented linear Paul trap in printed-circuit-board technology

G Huber, T. Deuschle, Wolfgang Schnitzler +3 more

We describe the construction and operation of a segmented linear Paul trap, fabricated in printed-circuit-board technology with an electrode segment width of 500 μm. We prove the applicability of this technology to reliable ion trapping and report the observation of Doppler-cooled ion crystals of 40 Ca + with this kind of trap. Measured trap frequencies agree with numerical simulations at the level of a few percent from which we infer a high fabrication accuracy of the segmented trap. To demonstrate its usefulness and versatility for trapped ion experiments we study the fast transport of a single ion. Our experimental results show a success rate of 99.0(1)% for a transport distance of 2 × 2 mm in a round-trip time of T = 20 μs, which corresponds to 4 axial oscillations only. We theoretically and experimentally investigate the excitation of oscillations caused by fast ion transports with error-function voltage ramps: for a slightly slower transport (a round-trip shuttle within T = 30 μs) we observe non-adiabatic motional excitation of 0.89(15) meV.

arXiv:0711.2947•New Journal of Physics•Jan 14, 2008•73 citations

A miniature linear RF ion trap

Jonathan Magnolia Gilligan, Christopher R. Monroe, David J. Wineland

We report on development of a miniature linear rf ion trap and preliminary efforts to trap and laser-cool {sup 24}Mg{sup +} ions. This trap has a radial dimension of 50 {mu}m, one tenth the size of our previous trap. The rms confinement of a trapped ion scales as R{sup -2}, where R is the trap radius, so tight confinement of ions is possible at a modest rf voltage. Although the three-dimensional trapping potential for our trap cannot be calculated analytically, it can be described in terms of dimensionless parameters, measured by studying macroscopic charged particles in a much larger model of the trap. We expect that with this trap it will be possible to achieve secular frequencies high enough for resolved-sideband cooling of light ions using allowed dipole transitions. This will make it much easier to perform experiments on the quantum motion of trapped ions. This trap uses a two-wire design rather than the more common four-wire one, so the trap electrodes occlude a much smaller solid angle than either a four-wire linear trap or the more common quadrupole trap. Thus, it will be possible to couple optical devices, such as high-finesse cavities, much more efficiently to trapped ions.

Bulletin of the American Physical Society•May 1, 1993•0 citations

Design and Characteristic Measurement of Miniature Three-Segment Linear Paul Trap

T. Furukawa, Jin Nishimura, U. Tanaka +1 more

We have fabricated a miniature three-segment linear Paul trap with r 0=0.6 mm and 2Z 0=4 mm. In order to perform quantum-state manipulation of trapped 40 Ca+ ions, we discuss the required harmonic oscillation frequencies which allow us to perform effective sideband cooling and have measured those that depend on the dimensions of the trap. A laser beam that has a component in the radial direction of the linear trap as well as that propagating along the trap axis has been used to detect the fluorescence spectra of the 42 S 1/2–42 P 1/2 transition. We have observed that the profile of the fluorescence spectrum obtained with the side laser beam is markedly different from that obtained with the axial laser beam due to micromotion. By applying additional DC voltages, the micromotion has been compensated, its amplitude has been estimated, and crystallization has been observed for two 40 Ca+ and four 40 Ca+ ions.

Japanese Journal of Applied Physics•Oct 1, 2005•10 citations

Demonstration experiments for the electronic detection of trapped ions in a linear Paul trap

Yuren Wang, Li-Bang Wang

We demonstrate a simple electronic detection method for trapped ions in a linear Paul trap. Singly charged calcium ions are confined in a linear Paul trap and are driven by an ac electric field at their secular frequency. The collective motion of the ions causes induced current on the trap electrodes, and the current signal is detected by a tuned circuit. This paper describes the design of the tuned circuit and the performance of this detection method. This method can be applied to various species of ions in different trap geometries. It serves as a simple tool to probe the existing ions in the trap, while in some cases, optical detection is not feasible. This method is particularly suitable for demonstration in teaching laboratories where the ion trap systems and detection circuits can be constructed by undergraduate students.

European Journal of Physics•Apr 8, 2013•4 citations

Stabilization of ion-trap secular frequencies for a quantum phase transition study

Jie Zhang, B. T. Chow, P. C. Haljan

An array of ions in a linear radio-frequency (RF) Paul trap is a good candidate for investigating structural phase transitions, such as the linear-to-zigzag (LZ) transition, due to the convenient control provided by modification of the trap confinement strength. In such studies, the trap secular frequencies are a key factor that limits the stability of the critical point (CP). In this paper, we implement secular-frequency stabilization, including active feedback stabilization of the RF voltage near the trap electrodes, and achieve a stability of better than 5~ppm over 200~s for both transverse and axial potentials. To evaluate the combined long-term stability of the trap potential in both directions, we measure the zigzag (ZZ) mode frequency near the CP, where the effect of instability in both trap directions is substantially amplified. The short-term noise within a limited spectral window is also suppressed by this scheme, as inferred from decoherence rates of the ZZ mode measured at different frequencies with Ramsey fringes. We also identify that the limitation of the secular frequency stability is mainly from the imperfect temperature insensitivity of voltage dividers and RF detectors, and as a result improvement of lab temperature stability is of great help for stabilizing the trap frequency.

arXiv:2210.14478•Oct 26, 2022•2 citations
We demonstrate a linear radio-frequency trap for confining strontium ions that is simply constructed nearly entirely with commercial off-the-shelf components. The electrodes of this trap are spaced to allow tight radial confinement, and segmented to give tight axial confinement with minimal distortion of the radio-frequency field. The resulting secular frequencies of the trap are 1 MHz in the radial direction and 100 kHz in the axial direction, the ions can be imaged with 2–3 μm resolution, and we detect over 20 000 photons per second per ion. This article describes the construction of the vital parts of the trap system, the laser system and optics used to Doppler cool the ions and to observe quantum jumps, and the operation and behavior of the complete system.
We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of Q ≈ 2.3 × 105 at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts that limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron-beam ion trap, and deceleration beamline supplying highly charged ions (HCIs), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole-mass filter with HCIs and trapping of Doppler-cooled 9Be+ Coulomb crystals.
We describe the construction and operation of a segmented linear Paul trap, fabricated in printed-circuit-board technology with an electrode segment width of 500 μm. We prove the applicability of this technology to reliable ion trapping and report the observation of Doppler-cooled ion crystals of 40 Ca + with this kind of trap. Measured trap frequencies agree with numerical simulations at the level of a few percent from which we infer a high fabrication accuracy of the segmented trap. To demonstrate its usefulness and versatility for trapped ion experiments we study the fast transport of a single ion. Our experimental results show a success rate of 99.0(1)% for a transport distance of 2 × 2 mm in a round-trip time of T = 20 μs, which corresponds to 4 axial oscillations only. We theoretically and experimentally investigate the excitation of oscillations caused by fast ion transports with error-function voltage ramps: for a slightly slower transport (a round-trip shuttle within T = 30 μs) we observe non-adiabatic motional excitation of 0.89(15) meV.
We report on development of a miniature linear rf ion trap and preliminary efforts to trap and laser-cool {sup 24}Mg{sup +} ions. This trap has a radial dimension of 50 {mu}m, one tenth the size of our previous trap. The rms confinement of a trapped ion scales as R{sup -2}, where R is the trap radius, so tight confinement of ions is possible at a modest rf voltage. Although the three-dimensional trapping potential for our trap cannot be calculated analytically, it can be described in terms of dimensionless parameters, measured by studying macroscopic charged particles in a much larger model of the trap. We expect that with this trap it will be possible to achieve secular frequencies high enough for resolved-sideband cooling of light ions using allowed dipole transitions. This will make it much easier to perform experiments on the quantum motion of trapped ions. This trap uses a two-wire design rather than the more common four-wire one, so the trap electrodes occlude a much smaller solid angle than either a four-wire linear trap or the more common quadrupole trap. Thus, it will be possible to couple optical devices, such as high-finesse cavities, much more efficiently to trapped ions.
We have fabricated a miniature three-segment linear Paul trap with r 0=0.6 mm and 2Z 0=4 mm. In order to perform quantum-state manipulation of trapped 40 Ca+ ions, we discuss the required harmonic oscillation frequencies which allow us to perform effective sideband cooling and have measured those that depend on the dimensions of the trap. A laser beam that has a component in the radial direction of the linear trap as well as that propagating along the trap axis has been used to detect the fluorescence spectra of the 42 S 1/2–42 P 1/2 transition. We have observed that the profile of the fluorescence spectrum obtained with the side laser beam is markedly different from that obtained with the axial laser beam due to micromotion. By applying additional DC voltages, the micromotion has been compensated, its amplitude has been estimated, and crystallization has been observed for two 40 Ca+ and four 40 Ca+ ions.
We demonstrate a simple electronic detection method for trapped ions in a linear Paul trap. Singly charged calcium ions are confined in a linear Paul trap and are driven by an ac electric field at their secular frequency. The collective motion of the ions causes induced current on the trap electrodes, and the current signal is detected by a tuned circuit. This paper describes the design of the tuned circuit and the performance of this detection method. This method can be applied to various species of ions in different trap geometries. It serves as a simple tool to probe the existing ions in the trap, while in some cases, optical detection is not feasible. This method is particularly suitable for demonstration in teaching laboratories where the ion trap systems and detection circuits can be constructed by undergraduate students.
An array of ions in a linear radio-frequency (RF) Paul trap is a good candidate for investigating structural phase transitions, such as the linear-to-zigzag (LZ) transition, due to the convenient control provided by modification of the trap confinement strength. In such studies, the trap secular frequencies are a key factor that limits the stability of the critical point (CP). In this paper, we implement secular-frequency stabilization, including active feedback stabilization of the RF voltage near the trap electrodes, and achieve a stability of better than 5~ppm over 200~s for both transverse and axial potentials. To evaluate the combined long-term stability of the trap potential in both directions, we measure the zigzag (ZZ) mode frequency near the CP, where the effect of instability in both trap directions is substantially amplified. The short-term noise within a limited spectral window is also suppressed by this scheme, as inferred from decoherence rates of the ZZ mode measured at different frequencies with Ramsey fringes. We also identify that the limitation of the secular frequency stability is mainly from the imperfect temperature insensitivity of voltage dividers and RF detectors, and as a result improvement of lab temperature stability is of great help for stabilizing the trap frequency.