Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2006.10405 · EPJ Web of Conferences

Toward a quantum-enhanced strontium optical lattice clock at INRIM

Marco G. Tarallo

Published Jan 1, 2020• 7 citations
arXivHTMLPDF

Abstract

The new strontium atomic clock at INRIM seeks to establish a new frontier in quantum measurement by joining state-of-the-art optical lattice clocks and the quantized electromagnetic field provided by a cavity QED setup. The goal of our experiment is to apply advanced quantum techniques to state-of-the-art optical lattice clocks, demonstrating enhanced sensitivity while preserving long coherence times and the highest accuracy. In this paper we describe the current status of the experiment and the prospected sensitivity gain for the designed cavity QED setup.

DOI
10.1051/epjconf/202023000011

Related papers

Toward a quantum-enhanced strontium optical lattice clock at INRIM

Marco G. Tarallo

The new strontium atomic clock at INRIM seeks to establish a new frontier in quantum measurement by joining state-of-the-art optical lattice clocks and the quantized electromagnetic field provided by a cavity QED setup. The goal of our experiment is to apply advanced quantum techniques to state-of-the-art optical lattice clocks, demonstrating enhanced sensitivity while preserving long coherence times and the highest accuracy. In this paper we describe the current status of the experiment and the prospected sensitivity gain for the designed cavity QED setup.

•Mar 11, 2020•6 citations

Status and Perspectives of INRIM Sr Cavity-Enhanced Optical Clock

Matteo Barbiero, Gianluca Bertaina, Davide Calonico +3 more

We report on the status of the strontium optical lattice clock at INRIM and its development towards a cavity-enhanced optical frequency standard exploiting quantum techniques. We have recently developed a novel method to perform high-fidelity spectral purity transfer based on serrodyne optical frequency shifting. We estimated the phase noise induced by the modulation setup by developing a novel composite self-heterodyne interferometer. The consequent short-term stability of our clock is presented, showing collision-limited interaction time in the bosonic88Sr clock. We also outline the progress towards a cavity-enhanced optical lattice clock. We present a numerical study on collective spin-squeezed states produced by QND continuous measurement of a lossy cavity and its relevance for a Sr optical lattice clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations

Advancing Optical Lattice Clocks: Accurate Measurements on a Bosonic System and Development of a Hybrid Cavity-Lattice Clock

Juan Pablo Salvatierra

This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .

•May 27, 2026•0 citations

Modifying strontium optical lattice clock for quantum simulation

Daniel C. Reed

Strontium optical lattice clocks represent the current state of the art in precise measurement of time. By trapping atoms at the antinodes of a one dimensional interference pattern of light, frequency shifts associated with the absorption and re-emission of photons used to probe the narrow linewidth clock transition can be avoided. In such a periodic system atoms develop a motional bandstructure analogous to electrons in condensed matter systems. By studying the behavior of atoms in the optical lattice we can, by analogy, gain understanding into the behavior of electrons in the solid state. Indeed, we can perform experiments which cannot be done in the real bulk material by controlling parameters which are impossible to change in macroscopic solids. \n \nIn this work we report on modifications to the existing strontium optical lattice clock experiment which have allowed the study of spin-orbit coupling. By dynamically ramping the intensity of one lattice beam during an experimental cycle we can study a regime in which the inter-site hopping rate J is sufficiently large that an atoms internal state can become coupled to its quasimomentum. The design requirements of the changes and the preliminary results are discussed.

•Dec 1, 2018•0 citations

A strontium optical lattice clock apparatus for precise frequency metrology and beyond

Marco G. Tarallo, Davide Calonico, Filippo Levi +3 more

We present the advancement toward the realization of a new optical clock apparatus based on ultracold strontium atoms. The atomic source employs a novel design based on two dimensional magneto optical trapping which is advantageous because of the suppression of thermal atoms in the interrogation volume, and the elimination of hot BBR in the view of the science cell. Compact frequency stabilization of cooling and trapping lasers is achieved via single PDH lock to a three-color ultrastable optical resonator. We also study different lattice topologies to operate the ultracold atomic ensemble in the high-cooperativity regime toward sub-quantum projection noise instability and millihertz-linewidth frequency stabilization by cavity QED.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•7 citations

INRIM Sr Optical Clock: An Optically Loaded Apparatus for High-Stability Metrology

Matteo Barbiero, Marco G. Tarallo, Federica Rullo +4 more

We report on the development of a new compact strontium optical lattice clock employing a 2D-MOT as cold atomic source. The clock system reliability is currently studied using the most abundant isotope, the bosonic88Sr. More than 10588Sr atoms are loaded in the optical lattice at 813 nm at temperatures of few microKelvin. All the needed optical frequencies are stabilized to a zero-CTE high finesse optical resonator, and can be operated without frequency adjustments for weeks. The system shows the advantage of optical guiding and switching the atomic source to the clock spectroscopy region by demonstrating more than 17 s lifetime. First spectroscopy tests on the clock transition on88Sr atoms has been performed by magnetic-field induced spectroscopy.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 7, 2021•1 citation
The new strontium atomic clock at INRIM seeks to establish a new frontier in quantum measurement by joining state-of-the-art optical lattice clocks and the quantized electromagnetic field provided by a cavity QED setup. The goal of our experiment is to apply advanced quantum techniques to state-of-the-art optical lattice clocks, demonstrating enhanced sensitivity while preserving long coherence times and the highest accuracy. In this paper we describe the current status of the experiment and the prospected sensitivity gain for the designed cavity QED setup.
The new strontium atomic clock at INRIM seeks to establish a new frontier in quantum measurement by joining state-of-the-art optical lattice clocks and the quantized electromagnetic field provided by a cavity QED setup. The goal of our experiment is to apply advanced quantum techniques to state-of-the-art optical lattice clocks, demonstrating enhanced sensitivity while preserving long coherence times and the highest accuracy. In this paper we describe the current status of the experiment and the prospected sensitivity gain for the designed cavity QED setup.
We report on the status of the strontium optical lattice clock at INRIM and its development towards a cavity-enhanced optical frequency standard exploiting quantum techniques. We have recently developed a novel method to perform high-fidelity spectral purity transfer based on serrodyne optical frequency shifting. We estimated the phase noise induced by the modulation setup by developing a novel composite self-heterodyne interferometer. The consequent short-term stability of our clock is presented, showing collision-limited interaction time in the bosonic88Sr clock. We also outline the progress towards a cavity-enhanced optical lattice clock. We present a numerical study on collective spin-squeezed states produced by QND continuous measurement of a lossy cavity and its relevance for a Sr optical lattice clock.
This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .
Strontium optical lattice clocks represent the current state of the art in precise measurement of time. By trapping atoms at the antinodes of a one dimensional interference pattern of light, frequency shifts associated with the absorption and re-emission of photons used to probe the narrow linewidth clock transition can be avoided. In such a periodic system atoms develop a motional bandstructure analogous to electrons in condensed matter systems. By studying the behavior of atoms in the optical lattice we can, by analogy, gain understanding into the behavior of electrons in the solid state. Indeed, we can perform experiments which cannot be done in the real bulk material by controlling parameters which are impossible to change in macroscopic solids. \n \nIn this work we report on modifications to the existing strontium optical lattice clock experiment which have allowed the study of spin-orbit coupling. By dynamically ramping the intensity of one lattice beam during an experimental cycle we can study a regime in which the inter-site hopping rate J is sufficiently large that an atoms internal state can become coupled to its quasimomentum. The design requirements of the changes and the preliminary results are discussed.
We present the advancement toward the realization of a new optical clock apparatus based on ultracold strontium atoms. The atomic source employs a novel design based on two dimensional magneto optical trapping which is advantageous because of the suppression of thermal atoms in the interrogation volume, and the elimination of hot BBR in the view of the science cell. Compact frequency stabilization of cooling and trapping lasers is achieved via single PDH lock to a three-color ultrastable optical resonator. We also study different lattice topologies to operate the ultracold atomic ensemble in the high-cooperativity regime toward sub-quantum projection noise instability and millihertz-linewidth frequency stabilization by cavity QED.
We report on the development of a new compact strontium optical lattice clock employing a 2D-MOT as cold atomic source. The clock system reliability is currently studied using the most abundant isotope, the bosonic88Sr. More than 10588Sr atoms are loaded in the optical lattice at 813 nm at temperatures of few microKelvin. All the needed optical frequencies are stabilized to a zero-CTE high finesse optical resonator, and can be operated without frequency adjustments for weeks. The system shows the advantage of optical guiding and switching the atomic source to the clock spectroscopy region by demonstrating more than 17 s lifetime. First spectroscopy tests on the clock transition on88Sr atoms has been performed by magnetic-field induced spectroscopy.