Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Status and Perspectives of INRIM Sr Cavity-Enhanced Optical Clock

Matteo Barbiero, Gianluca Bertaina, Davide Calonico, Filippo Levi, Juan Pablo Salvatierra, Marco G. Tarallo

Published May 15, 2023• 0 citations
Publisher

Abstract

We report on the status of the strontium optical lattice clock at INRIM and its development towards a cavity-enhanced optical frequency standard exploiting quantum techniques. We have recently developed a novel method to perform high-fidelity spectral purity transfer based on serrodyne optical frequency shifting. We estimated the phase noise induced by the modulation setup by developing a novel composite self-heterodyne interferometer. The consequent short-term stability of our clock is presented, showing collision-limited interaction time in the bosonic88Sr clock. We also outline the progress towards a cavity-enhanced optical lattice clock. We present a numerical study on collective spin-squeezed states produced by QND continuous measurement of a lossy cavity and its relevance for a Sr optical lattice clock.

DOI
10.1109/eftf/ifcs57587.2023.10272181

Related papers

Toward a quantum-enhanced strontium optical lattice clock at INRIM

Marco G. Tarallo

The new strontium atomic clock at INRIM seeks to establish a new frontier in quantum measurement by joining state-of-the-art optical lattice clocks and the quantized electromagnetic field provided by a cavity QED setup. The goal of our experiment is to apply advanced quantum techniques to state-of-the-art optical lattice clocks, demonstrating enhanced sensitivity while preserving long coherence times and the highest accuracy. In this paper we describe the current status of the experiment and the prospected sensitivity gain for the designed cavity QED setup.

•Mar 11, 2020•6 citations

Advancing Optical Lattice Clocks: Accurate Measurements on a Bosonic System and Development of a Hybrid Cavity-Lattice Clock

Juan Pablo Salvatierra

This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .

•May 27, 2026•0 citations

Toward a quantum-enhanced strontium optical lattice clock at INRIM

Marco G. Tarallo

The new strontium atomic clock at INRIM seeks to establish a new frontier in quantum measurement by joining state-of-the-art optical lattice clocks and the quantized electromagnetic field provided by a cavity QED setup. The goal of our experiment is to apply advanced quantum techniques to state-of-the-art optical lattice clocks, demonstrating enhanced sensitivity while preserving long coherence times and the highest accuracy. In this paper we describe the current status of the experiment and the prospected sensitivity gain for the designed cavity QED setup.

arXiv:2006.10405•EPJ Web of Conferences•Jan 1, 2020•7 citations

INRIM Sr Optical Clock: An Optically Loaded Apparatus for High-Stability Metrology

Matteo Barbiero, Marco G. Tarallo, Federica Rullo +4 more

We report on the development of a new compact strontium optical lattice clock employing a 2D-MOT as cold atomic source. The clock system reliability is currently studied using the most abundant isotope, the bosonic88Sr. More than 10588Sr atoms are loaded in the optical lattice at 813 nm at temperatures of few microKelvin. All the needed optical frequencies are stabilized to a zero-CTE high finesse optical resonator, and can be operated without frequency adjustments for weeks. The system shows the advantage of optical guiding and switching the atomic source to the clock spectroscopy region by demonstrating more than 17 s lifetime. First spectroscopy tests on the clock transition on88Sr atoms has been performed by magnetic-field induced spectroscopy.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 7, 2021•1 citation

Optical lattice clock on bosonic Strontium atoms

N. Poli, Marco G. Tarallo, M. Schioppo +4 more

We report on recent realization of an optical lattice clock operating on the1S0-3P0transition in88Sr, at LENS laboratories. The clock transition is excited with the technique of magnetic field-induced spectroscopy. New experimental techniques has also been developed in order to simplifies the clock spectroscopy in Sr atoms. The first new method helps in the first search of the clock transition without the use of extensive frequency metrology hardware and in particular optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0-3P0clock and1S0-3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger cooling transition. Secondly we reduce the complexity of the experimental setup by using only semiconductor laser sources in the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. We will present a first uncertainty budget for our optical lattice clock based on88Sr with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times. In view of an absolute frequency measurement of clock transition we'll also present recent experimental results on optimization of an home made Ti:Sa optical frequency comb. Additionally, we anticipate that the simplification of the experimental setup presented will help address a wider range of applications including those requiring transportable devices. Along these lines we will report progress on the realization of the first transportable Sr optical lattice clock.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•1 citation

An optical lattice clock based on bosonic Sr

N. Poli, Marco G. Tarallo, M. Schioppo +2 more

We present experimental results for an optical lattice clock operating on the1S0harr3P0transition in88Sr, which is excited with the technique of magnetic field-induced spectroscopy To reduce the complexity of the setup we have developed a set of new experimental techniques that greatly simplifies the clock spectroscopy in Sr atoms. First, we developed a method for finding the clock transition that removes the need for extensive frequency metrology hardware and optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0harr3P0clock and1S0harr3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger coolign transition Second, all laser sources in the experimental setup are based on semiconductor technology, which greatly reduces the complexity of the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. Preliminar uncertainty budget for our optical lattice clock is also presented, with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•1 citation
We report on the status of the strontium optical lattice clock at INRIM and its development towards a cavity-enhanced optical frequency standard exploiting quantum techniques. We have recently developed a novel method to perform high-fidelity spectral purity transfer based on serrodyne optical frequency shifting. We estimated the phase noise induced by the modulation setup by developing a novel composite self-heterodyne interferometer. The consequent short-term stability of our clock is presented, showing collision-limited interaction time in the bosonic88Sr clock. We also outline the progress towards a cavity-enhanced optical lattice clock. We present a numerical study on collective spin-squeezed states produced by QND continuous measurement of a lossy cavity and its relevance for a Sr optical lattice clock.
The new strontium atomic clock at INRIM seeks to establish a new frontier in quantum measurement by joining state-of-the-art optical lattice clocks and the quantized electromagnetic field provided by a cavity QED setup. The goal of our experiment is to apply advanced quantum techniques to state-of-the-art optical lattice clocks, demonstrating enhanced sensitivity while preserving long coherence times and the highest accuracy. In this paper we describe the current status of the experiment and the prospected sensitivity gain for the designed cavity QED setup.
This thesis presents advances on the bosonic 88 Sr optical lattice clock operated at INRiM, the Italian National Metrology Institute.Exploiting the recently upgraded clock laser frequency stability, and after realizing several improvements within the existing clock apparatus, this work presents a detailed characterization of the key systematic shifts affecting the clock, such as the quadratic Zeeman shift and the clock laser light shift, which are notoriously relevant for bosonic clocks.The lattice light AC Stark shift and other key systematics are also evaluated.The total fractional frequency uncertainty is evaluated to be 3.9 × 10 -16 , representing a nearly two orders of magnitude improvement with respect to the previous clock uncertainty budget assessment.Beyond its metrological evaluation, the optical lattice clock is used to investigate the interactions properties of 88 Sr by measuring collisional losses, decoherence, and density dependent frequency shifts in both one and two-dimensional optical lattices.Through these measurements, this work offers novel insights on the elastic interaction properties between excited-excited and ground-excited 88 Sr atoms, which allowed to provide estimates of the strength and sign of the relevant scattering parameters.In the final part, this thesis introduces the design and mechanical implementation of a cavity-enhanced extension of the optical lattice clock, which represents the future direction towards INRiM strontium clock is evolving to.The proposed system combines a magic-wavelength optical lattice with a cavity-QED architecture targeting strong, homogeneous, and collective coupling on the 1 S 0 ↔ 3 P 1 intercombination transition of strontium.This configuration enables non-destructive measurement schemes and the generation of collective atomic states, such as spin-squeezed states, with the potential to reduce quantum projection noise and improve clock stability.Furthermore, the system also provides a platform for exploring collective light-v matter phenomena, such as superradiant emission on both the red cooling and clock transitions.ix 6.3.2 Materials selection . . . . . .
The new strontium atomic clock at INRIM seeks to establish a new frontier in quantum measurement by joining state-of-the-art optical lattice clocks and the quantized electromagnetic field provided by a cavity QED setup. The goal of our experiment is to apply advanced quantum techniques to state-of-the-art optical lattice clocks, demonstrating enhanced sensitivity while preserving long coherence times and the highest accuracy. In this paper we describe the current status of the experiment and the prospected sensitivity gain for the designed cavity QED setup.
We report on the development of a new compact strontium optical lattice clock employing a 2D-MOT as cold atomic source. The clock system reliability is currently studied using the most abundant isotope, the bosonic88Sr. More than 10588Sr atoms are loaded in the optical lattice at 813 nm at temperatures of few microKelvin. All the needed optical frequencies are stabilized to a zero-CTE high finesse optical resonator, and can be operated without frequency adjustments for weeks. The system shows the advantage of optical guiding and switching the atomic source to the clock spectroscopy region by demonstrating more than 17 s lifetime. First spectroscopy tests on the clock transition on88Sr atoms has been performed by magnetic-field induced spectroscopy.
We report on recent realization of an optical lattice clock operating on the1S0-3P0transition in88Sr, at LENS laboratories. The clock transition is excited with the technique of magnetic field-induced spectroscopy. New experimental techniques has also been developed in order to simplifies the clock spectroscopy in Sr atoms. The first new method helps in the first search of the clock transition without the use of extensive frequency metrology hardware and in particular optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0-3P0clock and1S0-3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger cooling transition. Secondly we reduce the complexity of the experimental setup by using only semiconductor laser sources in the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. We will present a first uncertainty budget for our optical lattice clock based on88Sr with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times. In view of an absolute frequency measurement of clock transition we'll also present recent experimental results on optimization of an home made Ti:Sa optical frequency comb. Additionally, we anticipate that the simplification of the experimental setup presented will help address a wider range of applications including those requiring transportable devices. Along these lines we will report progress on the realization of the first transportable Sr optical lattice clock.
We present experimental results for an optical lattice clock operating on the1S0harr3P0transition in88Sr, which is excited with the technique of magnetic field-induced spectroscopy To reduce the complexity of the setup we have developed a set of new experimental techniques that greatly simplifies the clock spectroscopy in Sr atoms. First, we developed a method for finding the clock transition that removes the need for extensive frequency metrology hardware and optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0harr3P0clock and1S0harr3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger coolign transition Second, all laser sources in the experimental setup are based on semiconductor technology, which greatly reduces the complexity of the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. Preliminar uncertainty budget for our optical lattice clock is also presented, with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times.