Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

A strontium optical lattice clock apparatus for precise frequency metrology and beyond

Marco G. Tarallo, Davide Calonico, Filippo Levi, Matteo Barbiero, Giacomo Lamporesi, Gabriele Ferrari

Published Jul 1, 2017• 7 citations
Publisher

Abstract

We present the advancement toward the realization of a new optical clock apparatus based on ultracold strontium atoms. The atomic source employs a novel design based on two dimensional magneto optical trapping which is advantageous because of the suppression of thermal atoms in the interrogation volume, and the elimination of hot BBR in the view of the science cell. Compact frequency stabilization of cooling and trapping lasers is achieved via single PDH lock to a three-color ultrastable optical resonator. We also study different lattice topologies to operate the ultracold atomic ensemble in the high-cooperativity regime toward sub-quantum projection noise instability and millihertz-linewidth frequency stabilization by cavity QED.

DOI
10.1109/fcs.2017.8089020

Related papers

Optically Loaded Strontium Lattice Clock With a Single Multi-Wavelength Reference Cavity

Matteo Barbiero, Davide Calonico, Filippo Levi +1 more

We report on the realization of a new compact strontium optical clock using a 2-D magneto-optical-trap (2D-MOT) as cold atomic source and a multi-wavelength cavity as the frequency stabilization system. All needed optical frequencies are stabilized to a zero-thermal expansion high-finesse optical resonator and can be operated without frequency adjustments for weeks. We present the complete characterization of the apparatus. Optical control of the atomic source allows us to perform low-noise clock operation without atomic signal normalization. Long- and short-term stability tests of the clock have been performed for the88Sr bosonic isotope by means of interleaved clock operation. Finally, we present the first preliminary accuracy budget of the system.

arXiv:2111.10161•IEEE Transactions on Instrumentation and Measurement•Jan 1, 2022•16 citations

Towards miniaturized strontium optical lattice clock

Wei He

Optical atomic clocks with precisions and accuracies in the \n10\\(^-\\)\\(^1\\)\\(^8\\) level [1] are now the most advanced man-made timekeeping devices. They outperform the microwave cesium atomic clocks that realize the SI definition of the second. Scaling down the size of optical atomic clocks may open the door to a range of industrial and space applications. \n \nIn this thesis, the design and preliminary results of a compact strontium cooling system are presented. In the first cooling stage, the high power 461 nm laser with 300 mW output features a modular design, while smaller laser sources for demonstrating a strontium magneto-optical trap have also been investigated. An innovative design that couples a spectroscopy cell directly into the scientific chamber reduces the overall size and power consumption of the system. Additionally, using strontium oxide as a source of strontium atoms suitable for optical clocks has achieved initial success. For the first time, a single-beam MOT configuration is applied to strontium. In this novel apparatus, the blue MOT and red MOT broadband cooling phases are able to trap 5x10\\(^6\\) and 1000 atoms, respectively. This work shows promising progress towards developing a functional miniaturized strontium optical lattice clock.

•Jul 1, 2017•5 citations

Towards a strontium based stationary optical lattice clock

Qasim Hassan Ubaid

Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.

•Jul 20, 2020•0 citations

Strontium Optical Lattice Clock with All Semiconductor Sources

N. Poli, Robert E. Drullinger, Marco G. Tarallo +2 more

We report on our progress toward the realization of an optical frequency standard referenced to strontium intercombination lines. Our current setup allows the production of ultracold Sr atoms in hundreds of ms. For high resolution spectroscopy of1S0-3P0doubly forbidden transition we have also prepared a 698 nm clock laser stabilized on high finesse symmetrically suspended cavity and a high power 813 nm light source for the optical lattice trap at the magic wavelength. All the laser source employed are based on semiconductor device. This opens the way to the realization of compact, reliable and eventually transportable optical frequency standards.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2007•3 citations

Prospect for a compact strontium optical lattice clock

N. Poli, Robert E. Drullinger, G. Ferrari +4 more

We report on our progress toward the realization of a compact optical frequency standard referenced to strontium intercombination lines. Our current setup allows the production of ultracold Sr atoms in hundreds of ms. For high resolution spectroscopy of the 1S0-3P0 doubly forbidden transition we have prepared a 698 nm clock laser stabilized on a high finesse, symmetrically suspended cavity and a high power 813 nm light source for the optical lattice trap at the magic wavelength. Due to their compactness, reliability, and low power consumption, semiconductor laser sources represent the best choice for the development of compact and transportable devices for application both on Earth and in Space. A new Sr trapping and cooling experimental setup is also presented.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•9 citations

Development of an Apparatus for a Strontium Optical Lattice Optical Frequency Standard

Ian R. Hill

Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.

•Jun 1, 2012•3 citations
We present the advancement toward the realization of a new optical clock apparatus based on ultracold strontium atoms. The atomic source employs a novel design based on two dimensional magneto optical trapping which is advantageous because of the suppression of thermal atoms in the interrogation volume, and the elimination of hot BBR in the view of the science cell. Compact frequency stabilization of cooling and trapping lasers is achieved via single PDH lock to a three-color ultrastable optical resonator. We also study different lattice topologies to operate the ultracold atomic ensemble in the high-cooperativity regime toward sub-quantum projection noise instability and millihertz-linewidth frequency stabilization by cavity QED.
We report on the realization of a new compact strontium optical clock using a 2-D magneto-optical-trap (2D-MOT) as cold atomic source and a multi-wavelength cavity as the frequency stabilization system. All needed optical frequencies are stabilized to a zero-thermal expansion high-finesse optical resonator and can be operated without frequency adjustments for weeks. We present the complete characterization of the apparatus. Optical control of the atomic source allows us to perform low-noise clock operation without atomic signal normalization. Long- and short-term stability tests of the clock have been performed for the88Sr bosonic isotope by means of interleaved clock operation. Finally, we present the first preliminary accuracy budget of the system.
Optical atomic clocks with precisions and accuracies in the \n10\\(^-\\)\\(^1\\)\\(^8\\) level [1] are now the most advanced man-made timekeeping devices. They outperform the microwave cesium atomic clocks that realize the SI definition of the second. Scaling down the size of optical atomic clocks may open the door to a range of industrial and space applications. \n \nIn this thesis, the design and preliminary results of a compact strontium cooling system are presented. In the first cooling stage, the high power 461 nm laser with 300 mW output features a modular design, while smaller laser sources for demonstrating a strontium magneto-optical trap have also been investigated. An innovative design that couples a spectroscopy cell directly into the scientific chamber reduces the overall size and power consumption of the system. Additionally, using strontium oxide as a source of strontium atoms suitable for optical clocks has achieved initial success. For the first time, a single-beam MOT configuration is applied to strontium. In this novel apparatus, the blue MOT and red MOT broadband cooling phases are able to trap 5x10\\(^6\\) and 1000 atoms, respectively. This work shows promising progress towards developing a functional miniaturized strontium optical lattice clock.
Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.
We report on our progress toward the realization of an optical frequency standard referenced to strontium intercombination lines. Our current setup allows the production of ultracold Sr atoms in hundreds of ms. For high resolution spectroscopy of1S0-3P0doubly forbidden transition we have also prepared a 698 nm clock laser stabilized on high finesse symmetrically suspended cavity and a high power 813 nm light source for the optical lattice trap at the magic wavelength. All the laser source employed are based on semiconductor device. This opens the way to the realization of compact, reliable and eventually transportable optical frequency standards.
We report on our progress toward the realization of a compact optical frequency standard referenced to strontium intercombination lines. Our current setup allows the production of ultracold Sr atoms in hundreds of ms. For high resolution spectroscopy of the 1S0-3P0 doubly forbidden transition we have prepared a 698 nm clock laser stabilized on a high finesse, symmetrically suspended cavity and a high power 813 nm light source for the optical lattice trap at the magic wavelength. Due to their compactness, reliability, and low power consumption, semiconductor laser sources represent the best choice for the development of compact and transportable devices for application both on Earth and in Space. A new Sr trapping and cooling experimental setup is also presented.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.