Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Logic Spectroscopy of Highly Charged Ions

P. Micke

Published Jan 1, 2020• 1 citation
Publisher

Abstract

Fundamental interactions and symmetries define the structure and properties of all matter, in particular of its small and diverse visible constituents—the atoms. The study of their distinctive spectra through precision spectroscopy is therefore a vital tool to advance our understanding of nature. Highly charged ions (HCIs) constitute the largest fraction of all atoms since every atom has as many charge states as electrons it can bind. Although most of the matter on Earth is neutral, HCIs are ubiquitous in the universe and their systematic study is essential not only for atomic physics but eminently for astrophysics, nuclear physics, and fusion research, among others. Recently, HCIs have been identified as ideal candidates for sensitive tests of physics beyond the Standard Model of particle physics and for use in future high-accuracy optical atomic clocks. However, the realization of such proposals has been hindered by the hitherto constrained laboratory control and limited spectroscopic accuracy of about parts-per-million fractional uncertainty levels. This thesis reports the first coherent laser spectroscopy of HCIs, boosting the achievable spectroscopic precision by eight orders of magnitude compared to traditional spectroscopy methods. The 2P1/2–2P3/2 fine-structure ground-state transition in highly charged 40Ar13+ at an optical wavelength of 441 nm was chosen as a proof-of-principle case. A single ion of this species was isolated from a megakelvin-hot plasma cloud and co-trapped together with a laser-cooled singly charged 9Be+ ion in a two-ion crystal, confined in the harmonic potential of a cryogenic linear Paul trap. This coupled quantum-mechanical system was then cooled to its ground state of axial motion, corresponding to the lowest temperature of a HCI ever achieved. The spectroscopy was realized by implementing quantum logic techniques which allow preparation of the quantum state of the HCI and to map its electronic state after spectroscopy onto the 9Be+ logic ion in order to detect it there with high efficiency through electron shelving. In addition to the increase of spectroscopic precision, the excited-state lifetime and g-factor were measured—the latter one to unprecedented accuracy, resolving effects from special relativity, interelectronic interactions, and quantum electrodynamics. Moreover, it settled a discrepancy between theoretical predictions. The demonstrated techniques are not limited to the specific 40Ar13+ species but universally applicable to other HCIs. Thereby, this work unlocks the potential of HCIs for unrivaled tests of fundamental physics, the search for new physics—such as a 5th force, variations of fundamental constants and dark matter candidates—as well as the use of HCIs in novel optical atomic clocks.

DOI
10.7795/110.20201222

Related papers

Coulomb crystallization of highly charged ions

L. Schmöger, Oscar O. Versolato, M. Schwarz +13 more

Control over the motional degrees of freedom of atoms, ions, and molecules in a field-free environment enables unrivalled measurement accuracies but has yet to be applied to highly charged ions (HCIs), which are of particular interest to future atomic clock designs and searches for physics beyond the Standard Model. Here, we report on the Coulomb crystallization of HCIs (specifically (40)Ar(13+)) produced in an electron beam ion trap and retrapped in a cryogenic linear radiofrequency trap by means of sympathetic motional cooling through Coulomb interaction with a directly laser-cooled ensemble of Be(+) ions. We also demonstrate cooling of a single Ar(13+) ion by a single Be(+) ion-the prerequisite for quantum logic spectroscopy with a potential 10(-19) accuracy level. Achieving a seven-orders-of-magnitude decrease in HCI temperature starting at megakelvin down to the millikelvin range removes the major obstacle for HCI investigation with high-precision laser spectroscopy.

Science•Mar 12, 2015•137 citations

Towards direct frequency comb spectroscopy using quantum logic

Boerge Hemmerling

The possibility of variations of fundamental constants is highly debated and investigations have not yet reached a final conclusion.In the case of the fine-structure constant, the latest terrestrial experiments that employ ultra-precise spectroscopy on the timescales of a few years are consistent with no variation, whereas recent studies of quasar absorption spectra indicate a positive finding on both temporal and spatial variations of the fine-structure constant on astronomical scales.The astrophysical investigations strongly depend on accurate laboratory wavelength of a number of transitions of various complex ions, such as Ti + and Fe + , which, up to present, have resisted precision laser spectroscopy.In this thesis, a versatile setup that lays the basis to study such ions with a frequency comb as a spectroscopy source and theoretical calculations on the expected spectroscopy signal are presented.In this approach, the ions of interest (spectroscopy ions) are sympathetically cooled by wellcontrolled magnesium ions (logic ions) which are simultaneously stored in a Paul trap.Quantum logic techniques are employed to detect the spectroscopy signal from the spectroscopy ion on the logic ion.In contrast to previously implemented experiments that obtained precision data on such ions, the described apparatus is based on a single or a few ions and will therefore allow for isotope-selective spectroscopy.As an initial stage of the proposed spectroscopy scheme, a single 25 Mg + ion is cooled to the motional ground state of the trap confinement.The presented setup is a major simplification over previously used setups, since a single solid-state laser system is employed to cool, manipulate, repump and detect the logic ion.The cooling performance is studied by driving Raman-stimulated Rabi oscillations on the motional sidebands.An average motional population number of n = 0.03 ± 0.01 is achieved.Additionally, this work explores different detection schemes for 25 Mg + ions with potential application to other ions with hyperfine ground states.In contrast to the commonly implemented electron-shelving technique, the combination of electron-shelving with well-controllable radio-frequency induced spin-flips allows for post-selection of the observed statistics by filtering uncorrelated detection events.The achievable fidelity and the robustness of different detection strategies are studied.Future applications of the developed apparatus include deterministic state preparation and detection of molecular ions, highly charged ions and other exotic species for which laser cooling is not available.

•Jan 1, 2011•3 citations

Quantum Logic Techniques for Transition Metal and Molecular Ions

Till Rehmert

High-precision spectroscopy of atomic and molecular ions is an established platform for investigating fundamental aspects of physics. An important step in this direction was the development of quantum logic techniques that enable the spectroscopy of ions whose electronic structure does not allow direct laser cooling. Particularly challenging in this context is the investigation of atomic and molecular systems with many long-lived metastable states. The preparation of a pure quantum state for spectroscopy purposes often requires the prior detection of these long-lived states. For molecular ions, schemes for the detection of their rotational degree of freedom have already been developed in the past. However, quantum logic control of transition metals, in which the many metastable states result from several valence electrons, remained elusive. In this cumulative thesis, the first experimental implementation of a quantum logic assisted scheme for internal state detection of atomic systems as complex as a titanium ion is presented. Furthermore, a scheme based on simultaneous co-magnetometry for measuring the Landé g factor was developed and demonstrated for different fine structure states in 48Ti+. The presented method allows the suppression of systematic uncertainties arising from varying magnetic fields at the position of the ion and can be transferred to a variety of other species. Crucial for quantum logic based applications is the reliable preparation of a two-ion crystal consisting of one spectroscopy ion and one logic ion. A third aspect of this work is the deterministic preparation of such a two-ion crystal. The method based on fluorescence imaging is associated with a significantly reduced calibration effort compared to other schemes and can be easily transferred to other combinations of spectroscopy and logic ions. The quantum logic control capabilities demonstrated in this work are applicable to a wide range of other atoms with complex electronic structures as well as to molecular ions. The investigation of transition metals can provide important reference data for the calibration of absorption spectra from astrophysical objects. Molecular ions have applications in the search for a possible variation of fundamental constants or the measurement of energy shifts caused by an electron electric dipole moment, both representing promising approaches to test the standard model of particle physics.

•Jan 1, 2026•0 citations

Quantum logic spectroscopy of atomic and molecular ions

Wan, Yong

Laser spectroscopy is a versatile tool to investigate the internal structure of atoms, molecules and nuclei.High precision spectroscopy requires laser cooling to reduce Doppler broadening and Doppler shifts.Sympathetic cooling extends these advantages to species which do not have an appropriate transition for laser cooling and allows precision spectroscopy of previously inaccessible species using the quantum logic technique.The original implementation of quantum logic spectroscopy relies on the long lifetime of the excited spectroscopy state to realize a transfer sequence.Precision spectroscopy of transitions with a short-lived excited state is typically performed using laser induced uorescence or laser absorption spectroscopy.Neither of these methods has reached the fundamental quantum projection noise limit and are rather limited by photon shot noise.For these situations, we develop the technique of photon recoil spectroscopy as an extension of quantum logic spectroscopy to broad transitions.The common motion of a sideband-cooled two-ion crystal is excited by photon recoil during photon absorption on the spectroscopically investigated ion.This motional excitation is transferred to an internal state excitation on the co-trapped ion of a dierent species and detected with high eciency.We demonstrate the technique on the 2 S 1/2 ↔ 2 P 1/2 transition of the 40 Ca + ion and resolve the line center to 1/300 of its observed linewidth.The simplicity and versatility of the technique promises applications to other previously inaccessible species.A variation of the technique is proposed for rotational state preparation of molecular ions.A moving optical lattice is employed to exert a state-dependent force on the molecule.This would allow the detection of the rotational state of the molecular ion and therefore enable precision spectroscopy of specic rovibrational transitions in the molecule.

•Jan 1, 2014•0 citations

Extreme-ultraviolet spectroscopy using quantum logic: a feasibility study for the 1S-2S transition in singly-ionized helium

A. Martínez de Velasco, V. P. J. Barbé, E. L. Gründeman +10 more

Extreme-ultraviolet (XUV) spectroscopy represents an important new direction in precision physics, with potential applications ranging from the metrology of fundamental constants to tests of physics beyond the Standard Model. However, the application of quantum control methods for precision spectroscopy remains an open challenge in the XUV range. Here we present a novel quantum logic (QL) spectroscopy method for precision spectroscopy of weak XUV transitions, and numerically validate its feasibility for the $1S-2S$ transition at 40.81\,eV in singly-ionized helium (He$^{+}$). We propose a scheme based on a single He$^{+}$ ion co-trapped with a Be$^{+}$ ion in a Paul trap, and He$^{+}$ excitation with pairs of frequency-comb (FC) laser pulses upconverted to the XUV via High-Harmonic Generation (HHG). We investigate a nondestructive QL scheme to detect $1S-2S$ excitation, and compare its performance with a destructive readout based on state-selective ionization. Phase coherence of the XUV light is modelled and an optical cavity is used to filter the FC pulses prior to HHG. We model the motional excitation dynamics of trapped ions outside the Lamb-Dicke regime, and numerically validate a scheme we proposed in \cite{Grundeman} to cancel the first-order Doppler broadening and the recoil shift by synchronizing the ion's secular period with the time delay between the two excitation pulses. We show that precision spectroscopy of the $1S-2S$ transition in He$^{+}$ at the 10 kHz level is feasible, for improved tests of quantum electrodynamics (QED), a measurement of the Rydberg constant $R_{\infty}$ independent of hydrogen measurements, or an improved determination of the alpha particle and helion charge radii. The proposed method may also be applied to XUV spectroscopy of other ions outside the Lamb-Dicke regime.

physics.atom-phCross-listedarXiv:2608.23516•Aug 25, 2026

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

T. Leopold, S. A. King, P. Micke +5 more

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.

arXiv:1901.03082•Review of Scientific Instruments•Jul 1, 2019•55 citations
Fundamental interactions and symmetries define the structure and properties of all matter, in particular of its small and diverse visible constituents—the atoms. The study of their distinctive spectra through precision spectroscopy is therefore a vital tool to advance our understanding of nature. Highly charged ions (HCIs) constitute the largest fraction of all atoms since every atom has as many charge states as electrons it can bind. Although most of the matter on Earth is neutral, HCIs are ubiquitous in the universe and their systematic study is essential not only for atomic physics but eminently for astrophysics, nuclear physics, and fusion research, among others. Recently, HCIs have been identified as ideal candidates for sensitive tests of physics beyond the Standard Model of particle physics and for use in future high-accuracy optical atomic clocks. However, the realization of such proposals has been hindered by the hitherto constrained laboratory control and limited spectroscopic accuracy of about parts-per-million fractional uncertainty levels. This thesis reports the first coherent laser spectroscopy of HCIs, boosting the achievable spectroscopic precision by eight orders of magnitude compared to traditional spectroscopy methods. The 2P1/2–2P3/2 fine-structure ground-state transition in highly charged 40Ar13+ at an optical wavelength of 441 nm was chosen as a proof-of-principle case. A single ion of this species was isolated from a megakelvin-hot plasma cloud and co-trapped together with a laser-cooled singly charged 9Be+ ion in a two-ion crystal, confined in the harmonic potential of a cryogenic linear Paul trap. This coupled quantum-mechanical system was then cooled to its ground state of axial motion, corresponding to the lowest temperature of a HCI ever achieved. The spectroscopy was realized by implementing quantum logic techniques which allow preparation of the quantum state of the HCI and to map its electronic state after spectroscopy onto the 9Be+ logic ion in order to detect it there with high efficiency through electron shelving. In addition to the increase of spectroscopic precision, the excited-state lifetime and g-factor were measured—the latter one to unprecedented accuracy, resolving effects from special relativity, interelectronic interactions, and quantum electrodynamics. Moreover, it settled a discrepancy between theoretical predictions. The demonstrated techniques are not limited to the specific 40Ar13+ species but universally applicable to other HCIs. Thereby, this work unlocks the potential of HCIs for unrivaled tests of fundamental physics, the search for new physics—such as a 5th force, variations of fundamental constants and dark matter candidates—as well as the use of HCIs in novel optical atomic clocks.
Control over the motional degrees of freedom of atoms, ions, and molecules in a field-free environment enables unrivalled measurement accuracies but has yet to be applied to highly charged ions (HCIs), which are of particular interest to future atomic clock designs and searches for physics beyond the Standard Model. Here, we report on the Coulomb crystallization of HCIs (specifically (40)Ar(13+)) produced in an electron beam ion trap and retrapped in a cryogenic linear radiofrequency trap by means of sympathetic motional cooling through Coulomb interaction with a directly laser-cooled ensemble of Be(+) ions. We also demonstrate cooling of a single Ar(13+) ion by a single Be(+) ion-the prerequisite for quantum logic spectroscopy with a potential 10(-19) accuracy level. Achieving a seven-orders-of-magnitude decrease in HCI temperature starting at megakelvin down to the millikelvin range removes the major obstacle for HCI investigation with high-precision laser spectroscopy.
The possibility of variations of fundamental constants is highly debated and investigations have not yet reached a final conclusion.In the case of the fine-structure constant, the latest terrestrial experiments that employ ultra-precise spectroscopy on the timescales of a few years are consistent with no variation, whereas recent studies of quasar absorption spectra indicate a positive finding on both temporal and spatial variations of the fine-structure constant on astronomical scales.The astrophysical investigations strongly depend on accurate laboratory wavelength of a number of transitions of various complex ions, such as Ti + and Fe + , which, up to present, have resisted precision laser spectroscopy.In this thesis, a versatile setup that lays the basis to study such ions with a frequency comb as a spectroscopy source and theoretical calculations on the expected spectroscopy signal are presented.In this approach, the ions of interest (spectroscopy ions) are sympathetically cooled by wellcontrolled magnesium ions (logic ions) which are simultaneously stored in a Paul trap.Quantum logic techniques are employed to detect the spectroscopy signal from the spectroscopy ion on the logic ion.In contrast to previously implemented experiments that obtained precision data on such ions, the described apparatus is based on a single or a few ions and will therefore allow for isotope-selective spectroscopy.As an initial stage of the proposed spectroscopy scheme, a single 25 Mg + ion is cooled to the motional ground state of the trap confinement.The presented setup is a major simplification over previously used setups, since a single solid-state laser system is employed to cool, manipulate, repump and detect the logic ion.The cooling performance is studied by driving Raman-stimulated Rabi oscillations on the motional sidebands.An average motional population number of n = 0.03 ± 0.01 is achieved.Additionally, this work explores different detection schemes for 25 Mg + ions with potential application to other ions with hyperfine ground states.In contrast to the commonly implemented electron-shelving technique, the combination of electron-shelving with well-controllable radio-frequency induced spin-flips allows for post-selection of the observed statistics by filtering uncorrelated detection events.The achievable fidelity and the robustness of different detection strategies are studied.Future applications of the developed apparatus include deterministic state preparation and detection of molecular ions, highly charged ions and other exotic species for which laser cooling is not available.
High-precision spectroscopy of atomic and molecular ions is an established platform for investigating fundamental aspects of physics. An important step in this direction was the development of quantum logic techniques that enable the spectroscopy of ions whose electronic structure does not allow direct laser cooling. Particularly challenging in this context is the investigation of atomic and molecular systems with many long-lived metastable states. The preparation of a pure quantum state for spectroscopy purposes often requires the prior detection of these long-lived states. For molecular ions, schemes for the detection of their rotational degree of freedom have already been developed in the past. However, quantum logic control of transition metals, in which the many metastable states result from several valence electrons, remained elusive. In this cumulative thesis, the first experimental implementation of a quantum logic assisted scheme for internal state detection of atomic systems as complex as a titanium ion is presented. Furthermore, a scheme based on simultaneous co-magnetometry for measuring the Landé g factor was developed and demonstrated for different fine structure states in 48Ti+. The presented method allows the suppression of systematic uncertainties arising from varying magnetic fields at the position of the ion and can be transferred to a variety of other species. Crucial for quantum logic based applications is the reliable preparation of a two-ion crystal consisting of one spectroscopy ion and one logic ion. A third aspect of this work is the deterministic preparation of such a two-ion crystal. The method based on fluorescence imaging is associated with a significantly reduced calibration effort compared to other schemes and can be easily transferred to other combinations of spectroscopy and logic ions. The quantum logic control capabilities demonstrated in this work are applicable to a wide range of other atoms with complex electronic structures as well as to molecular ions. The investigation of transition metals can provide important reference data for the calibration of absorption spectra from astrophysical objects. Molecular ions have applications in the search for a possible variation of fundamental constants or the measurement of energy shifts caused by an electron electric dipole moment, both representing promising approaches to test the standard model of particle physics.
Laser spectroscopy is a versatile tool to investigate the internal structure of atoms, molecules and nuclei.High precision spectroscopy requires laser cooling to reduce Doppler broadening and Doppler shifts.Sympathetic cooling extends these advantages to species which do not have an appropriate transition for laser cooling and allows precision spectroscopy of previously inaccessible species using the quantum logic technique.The original implementation of quantum logic spectroscopy relies on the long lifetime of the excited spectroscopy state to realize a transfer sequence.Precision spectroscopy of transitions with a short-lived excited state is typically performed using laser induced uorescence or laser absorption spectroscopy.Neither of these methods has reached the fundamental quantum projection noise limit and are rather limited by photon shot noise.For these situations, we develop the technique of photon recoil spectroscopy as an extension of quantum logic spectroscopy to broad transitions.The common motion of a sideband-cooled two-ion crystal is excited by photon recoil during photon absorption on the spectroscopically investigated ion.This motional excitation is transferred to an internal state excitation on the co-trapped ion of a dierent species and detected with high eciency.We demonstrate the technique on the 2 S 1/2 ↔ 2 P 1/2 transition of the 40 Ca + ion and resolve the line center to 1/300 of its observed linewidth.The simplicity and versatility of the technique promises applications to other previously inaccessible species.A variation of the technique is proposed for rotational state preparation of molecular ions.A moving optical lattice is employed to exert a state-dependent force on the molecule.This would allow the detection of the rotational state of the molecular ion and therefore enable precision spectroscopy of specic rovibrational transitions in the molecule.
Extreme-ultraviolet (XUV) spectroscopy represents an important new direction in precision physics, with potential applications ranging from the metrology of fundamental constants to tests of physics beyond the Standard Model. However, the application of quantum control methods for precision spectroscopy remains an open challenge in the XUV range. Here we present a novel quantum logic (QL) spectroscopy method for precision spectroscopy of weak XUV transitions, and numerically validate its feasibility for the 1S−2S1S-2S1S−2S transition at 40.81\,eV in singly-ionized helium (He+^{+}+). We propose a scheme based on a single He+^{+}+ ion co-trapped with a Be+^{+}+ ion in a Paul trap, and He+^{+}+ excitation with pairs of frequency-comb (FC) laser pulses upconverted to the XUV via High-Harmonic Generation (HHG). We investigate a nondestructive QL scheme to detect 1S−2S1S-2S1S−2S excitation, and compare its performance with a destructive readout based on state-selective ionization. Phase coherence of the XUV light is modelled and an optical cavity is used to filter the FC pulses prior to HHG. We model the motional excitation dynamics of trapped ions outside the Lamb-Dicke regime, and numerically validate a scheme we proposed in \cite{Grundeman} to cancel the first-order Doppler broadening and the recoil shift by synchronizing the ion's secular period with the time delay between the two excitation pulses. We show that precision spectroscopy of the 1S−2S1S-2S1S−2S transition in He+^{+}+ at the 10 kHz level is feasible, for improved tests of quantum electrodynamics (QED), a measurement of the Rydberg constant R∞R_{\infty}R∞​ independent of hydrogen measurements, or an improved determination of the alpha particle and helion charge radii. The proposed method may also be applied to XUV spectroscopy of other ions outside the Lamb-Dicke regime.
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.